Cargando…

Evaluation of Flow Pattern in the Ascending Aorta in Patients with Repaired Tetralogy of Fallot Using Four-Dimensional Flow Magnetic Resonance Imaging

OBJECTIVE: To evaluate flow pattern characteristics in the ascending aorta (AA) with four-dimensional (4D)-flow MRI and to determine predictors of aortic dilatation late after tetralogy of Fallot (TOF) repair. MATERIALS AND METHODS: This study included 44 patients with repaired TOF (25 males and 19...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Suji, Kim, Young Jin, Jung, Jo Won, Choi, Jae Young, Park, Han Ki, Shin, Yu Rim, Choi, Byung Wook
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6715567/
https://www.ncbi.nlm.nih.gov/pubmed/31464112
http://dx.doi.org/10.3348/kjr.2019.0096
_version_ 1783447236425809920
author Lee, Suji
Kim, Young Jin
Jung, Jo Won
Choi, Jae Young
Park, Han Ki
Shin, Yu Rim
Choi, Byung Wook
author_facet Lee, Suji
Kim, Young Jin
Jung, Jo Won
Choi, Jae Young
Park, Han Ki
Shin, Yu Rim
Choi, Byung Wook
author_sort Lee, Suji
collection PubMed
description OBJECTIVE: To evaluate flow pattern characteristics in the ascending aorta (AA) with four-dimensional (4D)-flow MRI and to determine predictors of aortic dilatation late after tetralogy of Fallot (TOF) repair. MATERIALS AND METHODS: This study included 44 patients with repaired TOF (25 males and 19 females; mean age, 28.9 ± 8.4 years) and 11 volunteers (10 males and 1 female, mean age, 33.7 ± 8.8 years) who had undergone 4D-flow MRI. The aortic diameters, velocity, wall shear stress (WSS), flow jet angle (FJA), and flow displacement (FD) at the level of the sinotubular junction (STJ) and mid-AA were compared between the repaired TOF and volunteer groups. The hemodynamic and clinical parameters were also compared between the aortic dilatation and non-dilatation subgroups in the repaired TOF group. RESULTS: The diameters of the sinus of Valsalva, STJ, and AA were significantly higher in the repaired TOF group than in the volunteer group (p = 0.002, p < 0.001, and p = 0.013, respectively). The FJAs at the STJ and AA were significantly greater in the repaired TOF group (p < 0.001 and p = 0.003, respectively), while velocities and WSS parameters were significantly lower. FD showed no statistically significant difference (p = 0.817). In subgroup analysis, age at TOF repair was significantly higher (p = 0.039) and FJA at the level of the AA significantly greater (p = 0.003) and mean WSS were significantly lower (p = 0.039) in the aortic dilatation group. FD were higher in the aortic dilatation group without statistical significance (p = 0.217). CONCLUSION: Patients with repaired TOF have an increased FJA, dilated AA, and secondarily decreased WSS. In addition to known risk factors, flow eccentricity may affect aortic dilatation in patients with repaired TOF.
format Online
Article
Text
id pubmed-6715567
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-67155672019-09-05 Evaluation of Flow Pattern in the Ascending Aorta in Patients with Repaired Tetralogy of Fallot Using Four-Dimensional Flow Magnetic Resonance Imaging Lee, Suji Kim, Young Jin Jung, Jo Won Choi, Jae Young Park, Han Ki Shin, Yu Rim Choi, Byung Wook Korean J Radiol Cardiovascular Imaging OBJECTIVE: To evaluate flow pattern characteristics in the ascending aorta (AA) with four-dimensional (4D)-flow MRI and to determine predictors of aortic dilatation late after tetralogy of Fallot (TOF) repair. MATERIALS AND METHODS: This study included 44 patients with repaired TOF (25 males and 19 females; mean age, 28.9 ± 8.4 years) and 11 volunteers (10 males and 1 female, mean age, 33.7 ± 8.8 years) who had undergone 4D-flow MRI. The aortic diameters, velocity, wall shear stress (WSS), flow jet angle (FJA), and flow displacement (FD) at the level of the sinotubular junction (STJ) and mid-AA were compared between the repaired TOF and volunteer groups. The hemodynamic and clinical parameters were also compared between the aortic dilatation and non-dilatation subgroups in the repaired TOF group. RESULTS: The diameters of the sinus of Valsalva, STJ, and AA were significantly higher in the repaired TOF group than in the volunteer group (p = 0.002, p < 0.001, and p = 0.013, respectively). The FJAs at the STJ and AA were significantly greater in the repaired TOF group (p < 0.001 and p = 0.003, respectively), while velocities and WSS parameters were significantly lower. FD showed no statistically significant difference (p = 0.817). In subgroup analysis, age at TOF repair was significantly higher (p = 0.039) and FJA at the level of the AA significantly greater (p = 0.003) and mean WSS were significantly lower (p = 0.039) in the aortic dilatation group. FD were higher in the aortic dilatation group without statistical significance (p = 0.217). CONCLUSION: Patients with repaired TOF have an increased FJA, dilated AA, and secondarily decreased WSS. In addition to known risk factors, flow eccentricity may affect aortic dilatation in patients with repaired TOF. The Korean Society of Radiology 2019-09 2019-08-23 /pmc/articles/PMC6715567/ /pubmed/31464112 http://dx.doi.org/10.3348/kjr.2019.0096 Text en Copyright © 2019 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Cardiovascular Imaging
Lee, Suji
Kim, Young Jin
Jung, Jo Won
Choi, Jae Young
Park, Han Ki
Shin, Yu Rim
Choi, Byung Wook
Evaluation of Flow Pattern in the Ascending Aorta in Patients with Repaired Tetralogy of Fallot Using Four-Dimensional Flow Magnetic Resonance Imaging
title Evaluation of Flow Pattern in the Ascending Aorta in Patients with Repaired Tetralogy of Fallot Using Four-Dimensional Flow Magnetic Resonance Imaging
title_full Evaluation of Flow Pattern in the Ascending Aorta in Patients with Repaired Tetralogy of Fallot Using Four-Dimensional Flow Magnetic Resonance Imaging
title_fullStr Evaluation of Flow Pattern in the Ascending Aorta in Patients with Repaired Tetralogy of Fallot Using Four-Dimensional Flow Magnetic Resonance Imaging
title_full_unstemmed Evaluation of Flow Pattern in the Ascending Aorta in Patients with Repaired Tetralogy of Fallot Using Four-Dimensional Flow Magnetic Resonance Imaging
title_short Evaluation of Flow Pattern in the Ascending Aorta in Patients with Repaired Tetralogy of Fallot Using Four-Dimensional Flow Magnetic Resonance Imaging
title_sort evaluation of flow pattern in the ascending aorta in patients with repaired tetralogy of fallot using four-dimensional flow magnetic resonance imaging
topic Cardiovascular Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6715567/
https://www.ncbi.nlm.nih.gov/pubmed/31464112
http://dx.doi.org/10.3348/kjr.2019.0096
work_keys_str_mv AT leesuji evaluationofflowpatternintheascendingaortainpatientswithrepairedtetralogyoffallotusingfourdimensionalflowmagneticresonanceimaging
AT kimyoungjin evaluationofflowpatternintheascendingaortainpatientswithrepairedtetralogyoffallotusingfourdimensionalflowmagneticresonanceimaging
AT jungjowon evaluationofflowpatternintheascendingaortainpatientswithrepairedtetralogyoffallotusingfourdimensionalflowmagneticresonanceimaging
AT choijaeyoung evaluationofflowpatternintheascendingaortainpatientswithrepairedtetralogyoffallotusingfourdimensionalflowmagneticresonanceimaging
AT parkhanki evaluationofflowpatternintheascendingaortainpatientswithrepairedtetralogyoffallotusingfourdimensionalflowmagneticresonanceimaging
AT shinyurim evaluationofflowpatternintheascendingaortainpatientswithrepairedtetralogyoffallotusingfourdimensionalflowmagneticresonanceimaging
AT choibyungwook evaluationofflowpatternintheascendingaortainpatientswithrepairedtetralogyoffallotusingfourdimensionalflowmagneticresonanceimaging