Data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks

In a three-phase four-wire distribution network, the load unbalance can be compensated by the use of an unbalanced three-phase reactive compensator, containing six single-phase coils and capacitors, grouped into two distinct circuits, having Yn and delta connections. In (Pană et al., 2020) is presen...

Descripción completa

Detalles Bibliográficos
Autores principales: Pană, Adrian, Băloi, Alexandru, Molnar-Matei, Florin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6715832/
https://www.ncbi.nlm.nih.gov/pubmed/31485471
http://dx.doi.org/10.1016/j.dib.2019.104366
_version_ 1783447292569714688
author Pană, Adrian
Băloi, Alexandru
Molnar-Matei, Florin
author_facet Pană, Adrian
Băloi, Alexandru
Molnar-Matei, Florin
author_sort Pană, Adrian
collection PubMed
description In a three-phase four-wire distribution network, the load unbalance can be compensated by the use of an unbalanced three-phase reactive compensator, containing six single-phase coils and capacitors, grouped into two distinct circuits, having Yn and delta connections. In (Pană et al., 2020) is presented a method of calculating the equivalent susceptances of the six reactive elements, so that they are capacitive or null. The paper demonstrates that a power factor improvement and a total or partial balancing of an unbalanced inductive load can be achieved by using an unbalanced capacitive compensator. The calculation method can be implemented in the control system of a SVC containing only single-phase capacitor banks. In this DiB article are presented additional data and information, obtained by numerical analysis, simulation-modeling and experimental determinations performed with the purpose of validation of the calculation method proposed in (Pană et al., 2020).
format Online
Article
Text
id pubmed-6715832
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-67158322019-09-04 Data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks Pană, Adrian Băloi, Alexandru Molnar-Matei, Florin Data Brief Engineering In a three-phase four-wire distribution network, the load unbalance can be compensated by the use of an unbalanced three-phase reactive compensator, containing six single-phase coils and capacitors, grouped into two distinct circuits, having Yn and delta connections. In (Pană et al., 2020) is presented a method of calculating the equivalent susceptances of the six reactive elements, so that they are capacitive or null. The paper demonstrates that a power factor improvement and a total or partial balancing of an unbalanced inductive load can be achieved by using an unbalanced capacitive compensator. The calculation method can be implemented in the control system of a SVC containing only single-phase capacitor banks. In this DiB article are presented additional data and information, obtained by numerical analysis, simulation-modeling and experimental determinations performed with the purpose of validation of the calculation method proposed in (Pană et al., 2020). Elsevier 2019-08-08 /pmc/articles/PMC6715832/ /pubmed/31485471 http://dx.doi.org/10.1016/j.dib.2019.104366 Text en © 2019 The Author(s) http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Engineering
Pană, Adrian
Băloi, Alexandru
Molnar-Matei, Florin
Data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks
title Data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks
title_full Data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks
title_fullStr Data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks
title_full_unstemmed Data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks
title_short Data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks
title_sort data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks
topic Engineering
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6715832/
https://www.ncbi.nlm.nih.gov/pubmed/31485471
http://dx.doi.org/10.1016/j.dib.2019.104366
work_keys_str_mv AT panaadrian datafromnumericalanalysissimulationandexperimentaldeterminationsperformedtoverifythesizingofanunbalancedcapacitivecompensatorforthreephasefourwiresnetworks
AT baloialexandru datafromnumericalanalysissimulationandexperimentaldeterminationsperformedtoverifythesizingofanunbalancedcapacitivecompensatorforthreephasefourwiresnetworks
AT molnarmateiflorin datafromnumericalanalysissimulationandexperimentaldeterminationsperformedtoverifythesizingofanunbalancedcapacitivecompensatorforthreephasefourwiresnetworks