Data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks
In a three-phase four-wire distribution network, the load unbalance can be compensated by the use of an unbalanced three-phase reactive compensator, containing six single-phase coils and capacitors, grouped into two distinct circuits, having Yn and delta connections. In (Pană et al., 2020) is presen...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6715832/ https://www.ncbi.nlm.nih.gov/pubmed/31485471 http://dx.doi.org/10.1016/j.dib.2019.104366 |
_version_ | 1783447292569714688 |
---|---|
author | Pană, Adrian Băloi, Alexandru Molnar-Matei, Florin |
author_facet | Pană, Adrian Băloi, Alexandru Molnar-Matei, Florin |
author_sort | Pană, Adrian |
collection | PubMed |
description | In a three-phase four-wire distribution network, the load unbalance can be compensated by the use of an unbalanced three-phase reactive compensator, containing six single-phase coils and capacitors, grouped into two distinct circuits, having Yn and delta connections. In (Pană et al., 2020) is presented a method of calculating the equivalent susceptances of the six reactive elements, so that they are capacitive or null. The paper demonstrates that a power factor improvement and a total or partial balancing of an unbalanced inductive load can be achieved by using an unbalanced capacitive compensator. The calculation method can be implemented in the control system of a SVC containing only single-phase capacitor banks. In this DiB article are presented additional data and information, obtained by numerical analysis, simulation-modeling and experimental determinations performed with the purpose of validation of the calculation method proposed in (Pană et al., 2020). |
format | Online Article Text |
id | pubmed-6715832 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-67158322019-09-04 Data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks Pană, Adrian Băloi, Alexandru Molnar-Matei, Florin Data Brief Engineering In a three-phase four-wire distribution network, the load unbalance can be compensated by the use of an unbalanced three-phase reactive compensator, containing six single-phase coils and capacitors, grouped into two distinct circuits, having Yn and delta connections. In (Pană et al., 2020) is presented a method of calculating the equivalent susceptances of the six reactive elements, so that they are capacitive or null. The paper demonstrates that a power factor improvement and a total or partial balancing of an unbalanced inductive load can be achieved by using an unbalanced capacitive compensator. The calculation method can be implemented in the control system of a SVC containing only single-phase capacitor banks. In this DiB article are presented additional data and information, obtained by numerical analysis, simulation-modeling and experimental determinations performed with the purpose of validation of the calculation method proposed in (Pană et al., 2020). Elsevier 2019-08-08 /pmc/articles/PMC6715832/ /pubmed/31485471 http://dx.doi.org/10.1016/j.dib.2019.104366 Text en © 2019 The Author(s) http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Engineering Pană, Adrian Băloi, Alexandru Molnar-Matei, Florin Data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks |
title | Data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks |
title_full | Data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks |
title_fullStr | Data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks |
title_full_unstemmed | Data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks |
title_short | Data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks |
title_sort | data from numerical analysis, simulation and experimental determinations performed to verify the sizing of an unbalanced capacitive compensator for three-phase four-wires networks |
topic | Engineering |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6715832/ https://www.ncbi.nlm.nih.gov/pubmed/31485471 http://dx.doi.org/10.1016/j.dib.2019.104366 |
work_keys_str_mv | AT panaadrian datafromnumericalanalysissimulationandexperimentaldeterminationsperformedtoverifythesizingofanunbalancedcapacitivecompensatorforthreephasefourwiresnetworks AT baloialexandru datafromnumericalanalysissimulationandexperimentaldeterminationsperformedtoverifythesizingofanunbalancedcapacitivecompensatorforthreephasefourwiresnetworks AT molnarmateiflorin datafromnumericalanalysissimulationandexperimentaldeterminationsperformedtoverifythesizingofanunbalancedcapacitivecompensatorforthreephasefourwiresnetworks |