Assessing the Usability of an Automated Continuous Temperature Monitoring Device (iThermonitor) in Pediatric Patients: Non-Randomized Pilot Study
BACKGROUND: Fever is an important vital sign and often the first one to be assessed in a sick child. In acutely ill children, caregivers are expected to monitor a child’s body temperature at home after an initial medical consult. Fever literacy of many caregivers is known to be poor, leading to feve...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
JMIR Publications
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6716441/ https://www.ncbi.nlm.nih.gov/pubmed/31518304 http://dx.doi.org/10.2196/10804 |
_version_ | 1783447377014685696 |
---|---|
author | Kakarmath, Sujay S de Redon, Emily Centi, Amanda Jayne Palacholla, Ramya Kvedar, Joseph Jethwani, Kamal Agboola, Stephen |
author_facet | Kakarmath, Sujay S de Redon, Emily Centi, Amanda Jayne Palacholla, Ramya Kvedar, Joseph Jethwani, Kamal Agboola, Stephen |
author_sort | Kakarmath, Sujay S |
collection | PubMed |
description | BACKGROUND: Fever is an important vital sign and often the first one to be assessed in a sick child. In acutely ill children, caregivers are expected to monitor a child’s body temperature at home after an initial medical consult. Fever literacy of many caregivers is known to be poor, leading to fever phobia. In children with a serious illness, the responsibility of periodically monitoring temperature can add substantially to the already stressful experience of caring for a sick child. OBJECTIVE: The objective of this pilot study was to assess the feasibility of using the iThermonitor, an automated temperature measurement device, for continuous temperature monitoring in postoperative and postchemotherapy pediatric patients. METHODS: We recruited 25 patient-caregiver dyads from the Pediatric Surgery Department at the Massachusetts General Hospital (MGH) and the Pediatric Cancer Centers at the MGH and the Dana Farber Cancer Institute. Enrolled dyads were asked to use the iThermonitor device for continuous temperature monitoring over a 2-week period. Surveys were administered to caregivers at enrollment and at study closeout. Caregivers were also asked to complete a daily event-monitoring log. The Generalized Anxiety Disorder-7 item questionnaire was also used to assess caregiver anxiety at enrollment and closeout. RESULTS: Overall, 19 participant dyads completed the study. All 19 caregivers reported to have viewed temperature data on the study-provided iPad tablet at least once per day, and more than a third caregivers did so six or more times per day. Of all participants, 74% (14/19) reported experiencing an out-of-range temperature alert at least once during the study. Majority of caregivers reported that it was easy to learn how to use the device and that they felt confident about monitoring their child’s temperature with it. Only 21% (4/9) of caregivers reported concurrently using a device other than the iThermonitor to monitor their child’s temperature during the study. Continuous temperature monitoring was not associated with an increase in caregiver anxiety. CONCLUSIONS: The study results reveal that the iThermonitor is a highly feasible and easy-to-use device for continuous temperature monitoring in pediatric oncology and surgery patients. TRIAL REGISTRATION: ClinicalTrials.gov NCT02410252; https://clinicaltrials.gov/ct2/show/NCT02410252 (Archived by WebCite at http://www.webcitation.org/73LnO7hel) |
format | Online Article Text |
id | pubmed-6716441 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | JMIR Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-67164412019-09-17 Assessing the Usability of an Automated Continuous Temperature Monitoring Device (iThermonitor) in Pediatric Patients: Non-Randomized Pilot Study Kakarmath, Sujay S de Redon, Emily Centi, Amanda Jayne Palacholla, Ramya Kvedar, Joseph Jethwani, Kamal Agboola, Stephen JMIR Pediatr Parent Original Paper BACKGROUND: Fever is an important vital sign and often the first one to be assessed in a sick child. In acutely ill children, caregivers are expected to monitor a child’s body temperature at home after an initial medical consult. Fever literacy of many caregivers is known to be poor, leading to fever phobia. In children with a serious illness, the responsibility of periodically monitoring temperature can add substantially to the already stressful experience of caring for a sick child. OBJECTIVE: The objective of this pilot study was to assess the feasibility of using the iThermonitor, an automated temperature measurement device, for continuous temperature monitoring in postoperative and postchemotherapy pediatric patients. METHODS: We recruited 25 patient-caregiver dyads from the Pediatric Surgery Department at the Massachusetts General Hospital (MGH) and the Pediatric Cancer Centers at the MGH and the Dana Farber Cancer Institute. Enrolled dyads were asked to use the iThermonitor device for continuous temperature monitoring over a 2-week period. Surveys were administered to caregivers at enrollment and at study closeout. Caregivers were also asked to complete a daily event-monitoring log. The Generalized Anxiety Disorder-7 item questionnaire was also used to assess caregiver anxiety at enrollment and closeout. RESULTS: Overall, 19 participant dyads completed the study. All 19 caregivers reported to have viewed temperature data on the study-provided iPad tablet at least once per day, and more than a third caregivers did so six or more times per day. Of all participants, 74% (14/19) reported experiencing an out-of-range temperature alert at least once during the study. Majority of caregivers reported that it was easy to learn how to use the device and that they felt confident about monitoring their child’s temperature with it. Only 21% (4/9) of caregivers reported concurrently using a device other than the iThermonitor to monitor their child’s temperature during the study. Continuous temperature monitoring was not associated with an increase in caregiver anxiety. CONCLUSIONS: The study results reveal that the iThermonitor is a highly feasible and easy-to-use device for continuous temperature monitoring in pediatric oncology and surgery patients. TRIAL REGISTRATION: ClinicalTrials.gov NCT02410252; https://clinicaltrials.gov/ct2/show/NCT02410252 (Archived by WebCite at http://www.webcitation.org/73LnO7hel) JMIR Publications 2018-12-21 /pmc/articles/PMC6716441/ /pubmed/31518304 http://dx.doi.org/10.2196/10804 Text en ©Sujay S Kakarmath, Emily de Redon, Amanda Jayne Centi, Ramya Palacholla, Joseph Kvedar, Kamal Jethwani, Stephen Agboola. Originally published in JMIR Pediatrics and Parenting (http://pediatrics.jmir.org), 21.12.2018. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Pediatrics and Parenting, is properly cited. The complete bibliographic information, a link to the original publication on http://pediatrics.jmir.org, as well as this copyright and license information must be included. |
spellingShingle | Original Paper Kakarmath, Sujay S de Redon, Emily Centi, Amanda Jayne Palacholla, Ramya Kvedar, Joseph Jethwani, Kamal Agboola, Stephen Assessing the Usability of an Automated Continuous Temperature Monitoring Device (iThermonitor) in Pediatric Patients: Non-Randomized Pilot Study |
title | Assessing the Usability of an Automated Continuous Temperature Monitoring Device (iThermonitor) in Pediatric Patients: Non-Randomized Pilot Study |
title_full | Assessing the Usability of an Automated Continuous Temperature Monitoring Device (iThermonitor) in Pediatric Patients: Non-Randomized Pilot Study |
title_fullStr | Assessing the Usability of an Automated Continuous Temperature Monitoring Device (iThermonitor) in Pediatric Patients: Non-Randomized Pilot Study |
title_full_unstemmed | Assessing the Usability of an Automated Continuous Temperature Monitoring Device (iThermonitor) in Pediatric Patients: Non-Randomized Pilot Study |
title_short | Assessing the Usability of an Automated Continuous Temperature Monitoring Device (iThermonitor) in Pediatric Patients: Non-Randomized Pilot Study |
title_sort | assessing the usability of an automated continuous temperature monitoring device (ithermonitor) in pediatric patients: non-randomized pilot study |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6716441/ https://www.ncbi.nlm.nih.gov/pubmed/31518304 http://dx.doi.org/10.2196/10804 |
work_keys_str_mv | AT kakarmathsujays assessingtheusabilityofanautomatedcontinuoustemperaturemonitoringdeviceithermonitorinpediatricpatientsnonrandomizedpilotstudy AT deredonemily assessingtheusabilityofanautomatedcontinuoustemperaturemonitoringdeviceithermonitorinpediatricpatientsnonrandomizedpilotstudy AT centiamandajayne assessingtheusabilityofanautomatedcontinuoustemperaturemonitoringdeviceithermonitorinpediatricpatientsnonrandomizedpilotstudy AT palachollaramya assessingtheusabilityofanautomatedcontinuoustemperaturemonitoringdeviceithermonitorinpediatricpatientsnonrandomizedpilotstudy AT kvedarjoseph assessingtheusabilityofanautomatedcontinuoustemperaturemonitoringdeviceithermonitorinpediatricpatientsnonrandomizedpilotstudy AT jethwanikamal assessingtheusabilityofanautomatedcontinuoustemperaturemonitoringdeviceithermonitorinpediatricpatientsnonrandomizedpilotstudy AT agboolastephen assessingtheusabilityofanautomatedcontinuoustemperaturemonitoringdeviceithermonitorinpediatricpatientsnonrandomizedpilotstudy |