Cargando…

Postural control in girls with adolescent idiopathic scoliosis while wearing a Chêneau brace or performing active self-correction: a pilot study

BACKGROUND: It is known that adolescent idiopathic scoliosis (AIS) is often accompanied by balance deficits. This reciprocal relationship must be taken into account when prescribing new therapeutic modalities because these may differently affect postural control, interacting with therapy and influen...

Descripción completa

Detalles Bibliográficos
Autores principales: Piątek, Elżbieta, Kuczyński, Michał, Ostrowska, Bożena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PeerJ Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6717654/
https://www.ncbi.nlm.nih.gov/pubmed/31528504
http://dx.doi.org/10.7717/peerj.7513
_version_ 1783447592758149120
author Piątek, Elżbieta
Kuczyński, Michał
Ostrowska, Bożena
author_facet Piątek, Elżbieta
Kuczyński, Michał
Ostrowska, Bożena
author_sort Piątek, Elżbieta
collection PubMed
description BACKGROUND: It is known that adolescent idiopathic scoliosis (AIS) is often accompanied by balance deficits. This reciprocal relationship must be taken into account when prescribing new therapeutic modalities because these may differently affect postural control, interacting with therapy and influencing its results. OBJECTIVE: The purpose was to compare postural control in girls with AIS while wearing the Chêneau brace (BRA) or performing active self-correction (ASC) with their postural control in a quiet comfortable stance. METHODS: Nine subjects were evaluated on a force plate in three series of two 20-s quiet standing trials with eyes open or closed; three blocks were randomly arranged: normal quiet stance (QST), quiet stance with BRA, and quiet stance with ASC. On the basis of centre-of-pressure (COP) recordings, the spatial and temporal COP parameters were computed. RESULTS AND DISCUSSION: Performing ASC was associated with a significant backward excursion of the COP mean position with eyes open and closed (ES = 0.56 and 0.65, respectively; p < 0.05). This excursion was accompanied by an increase in the COP fractal dimension (ES = 1.05 and 0.98; p < 0.05) and frequency (ES = 0.78; p = 0.10 and ES = 1.14; p < 0.05) in the mediolateral (ML) plane. Finally, both therapeutic modalities decreased COP sample entropy with eyes closed in the anteroposterior (AP) plane. Wearing BRA resulted in ES = 1.45 (p < 0.05) while performing ASC in ES = 0.76 (p = 0.13). CONCLUSION: The observed changes in the fractal dimension (complexity) and frequency caused by ASC account for better adaptability of patients to environmental demands and for their adequate resources of available postural strategies in the ML plane. These changes in sway structure were accompanied by a significant (around 25 mm) backward excursion of the mean COP position. However, this improvement was achieved at the cost of lower automaticity, i.e. higher attentional involvement in postural control in the AP plane. Wearing BRA may have an undesirable effect on some aspects of body balance.
format Online
Article
Text
id pubmed-6717654
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher PeerJ Inc.
record_format MEDLINE/PubMed
spelling pubmed-67176542019-09-16 Postural control in girls with adolescent idiopathic scoliosis while wearing a Chêneau brace or performing active self-correction: a pilot study Piątek, Elżbieta Kuczyński, Michał Ostrowska, Bożena PeerJ Bioengineering BACKGROUND: It is known that adolescent idiopathic scoliosis (AIS) is often accompanied by balance deficits. This reciprocal relationship must be taken into account when prescribing new therapeutic modalities because these may differently affect postural control, interacting with therapy and influencing its results. OBJECTIVE: The purpose was to compare postural control in girls with AIS while wearing the Chêneau brace (BRA) or performing active self-correction (ASC) with their postural control in a quiet comfortable stance. METHODS: Nine subjects were evaluated on a force plate in three series of two 20-s quiet standing trials with eyes open or closed; three blocks were randomly arranged: normal quiet stance (QST), quiet stance with BRA, and quiet stance with ASC. On the basis of centre-of-pressure (COP) recordings, the spatial and temporal COP parameters were computed. RESULTS AND DISCUSSION: Performing ASC was associated with a significant backward excursion of the COP mean position with eyes open and closed (ES = 0.56 and 0.65, respectively; p < 0.05). This excursion was accompanied by an increase in the COP fractal dimension (ES = 1.05 and 0.98; p < 0.05) and frequency (ES = 0.78; p = 0.10 and ES = 1.14; p < 0.05) in the mediolateral (ML) plane. Finally, both therapeutic modalities decreased COP sample entropy with eyes closed in the anteroposterior (AP) plane. Wearing BRA resulted in ES = 1.45 (p < 0.05) while performing ASC in ES = 0.76 (p = 0.13). CONCLUSION: The observed changes in the fractal dimension (complexity) and frequency caused by ASC account for better adaptability of patients to environmental demands and for their adequate resources of available postural strategies in the ML plane. These changes in sway structure were accompanied by a significant (around 25 mm) backward excursion of the mean COP position. However, this improvement was achieved at the cost of lower automaticity, i.e. higher attentional involvement in postural control in the AP plane. Wearing BRA may have an undesirable effect on some aspects of body balance. PeerJ Inc. 2019-08-29 /pmc/articles/PMC6717654/ /pubmed/31528504 http://dx.doi.org/10.7717/peerj.7513 Text en ©2019 Piątek et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited.
spellingShingle Bioengineering
Piątek, Elżbieta
Kuczyński, Michał
Ostrowska, Bożena
Postural control in girls with adolescent idiopathic scoliosis while wearing a Chêneau brace or performing active self-correction: a pilot study
title Postural control in girls with adolescent idiopathic scoliosis while wearing a Chêneau brace or performing active self-correction: a pilot study
title_full Postural control in girls with adolescent idiopathic scoliosis while wearing a Chêneau brace or performing active self-correction: a pilot study
title_fullStr Postural control in girls with adolescent idiopathic scoliosis while wearing a Chêneau brace or performing active self-correction: a pilot study
title_full_unstemmed Postural control in girls with adolescent idiopathic scoliosis while wearing a Chêneau brace or performing active self-correction: a pilot study
title_short Postural control in girls with adolescent idiopathic scoliosis while wearing a Chêneau brace or performing active self-correction: a pilot study
title_sort postural control in girls with adolescent idiopathic scoliosis while wearing a chêneau brace or performing active self-correction: a pilot study
topic Bioengineering
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6717654/
https://www.ncbi.nlm.nih.gov/pubmed/31528504
http://dx.doi.org/10.7717/peerj.7513
work_keys_str_mv AT piatekelzbieta posturalcontrolingirlswithadolescentidiopathicscoliosiswhilewearingacheneaubraceorperformingactiveselfcorrectionapilotstudy
AT kuczynskimichał posturalcontrolingirlswithadolescentidiopathicscoliosiswhilewearingacheneaubraceorperformingactiveselfcorrectionapilotstudy
AT ostrowskabozena posturalcontrolingirlswithadolescentidiopathicscoliosiswhilewearingacheneaubraceorperformingactiveselfcorrectionapilotstudy