Cargando…

Dynamic quantitative nonenhanced magnetic resonance angiography of the abdominal aorta and lower extremities using cine fast interrupted steady-state in combination with arterial spin labeling: a feasibility study

BACKGROUND: Cine fast interrupted steady-state in combination with arterial spin labeling is a recently described nonenhanced magnetic resonance angiography (MRA) technique that relies on bolus tracking for time-resolved digital subtraction angiography-like displays of blood flow patterns. We evalua...

Descripción completa

Detalles Bibliográficos
Autores principales: Aherne, Emily A., Koktzoglou, Ioannis, Lind, Benjamin B., Edelman, Robert R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6717984/
https://www.ncbi.nlm.nih.gov/pubmed/31474219
http://dx.doi.org/10.1186/s12968-019-0562-3
_version_ 1783447656513667072
author Aherne, Emily A.
Koktzoglou, Ioannis
Lind, Benjamin B.
Edelman, Robert R.
author_facet Aherne, Emily A.
Koktzoglou, Ioannis
Lind, Benjamin B.
Edelman, Robert R.
author_sort Aherne, Emily A.
collection PubMed
description BACKGROUND: Cine fast interrupted steady-state in combination with arterial spin labeling is a recently described nonenhanced magnetic resonance angiography (MRA) technique that relies on bolus tracking for time-resolved digital subtraction angiography-like displays of blood flow patterns. We evaluated the feasibility of applying this technique to display in-plane flow patterns in two regions: the abdominal aorta and lower extremity peripheral arteries. METHODS: We performed an institutional review board-approved study in healthy subjects and patients. In 7 healthy subjects, in-plane flow was imaged at 4 stations ranging from the lower legs to the aorto-iliac bifurcation (junction of the distal thigh and upper calf, mid-thigh, junction of the upper thigh and pelvis, upper pelvis). In 5 healthy subjects and 6 patients without abdominal aortopathy, images were acquired through the suprarenal abdominal aorta. Ten patients with known peripheral arterial disease and two patients with stable disease of the abdominal aorta were also evaluated. Peak velocity was compared at each of the 4 stations for cine fast interrupted steady-state in combination with arterial spin labeling and two-dimensional cine phase contrast in patients with normal vessels. RESULTS: In-plane flow patterns were well visualized in all peripheral arterial stations and in the abdominal aorta, providing a high quality display of hemodynamic patterns along extensive lengths of the vessels. There was very strong positive correlation (r = 0.952, P < 0.05) and excellent agreement (intraclass correlation coefficient, 0.935; 95% confidence interval, 0.812–0.972) between peak flow velocities measured by cine fast interrupted steady-state in combination with arterial spin labeling and two-dimensional cine phase contrast. In 10 patients with peripheral artery disease and 2 patients with aortic pathology, cine fast interrupted steady-state in combination with arterial spin labeling provided a visual demonstration of abnormal hemodynamics. CONCLUSION: This feasibility study suggests that cine fast interrupted steady-state in combination with arterial spin labeling provides an efficient, high quality and physiologically accurate display of in-plane flow patterns over extensive lengths of the lower extremity peripheral arteries, which can be difficult to achieve using other MRA techniques. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12968-019-0562-3) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6717984
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-67179842019-09-06 Dynamic quantitative nonenhanced magnetic resonance angiography of the abdominal aorta and lower extremities using cine fast interrupted steady-state in combination with arterial spin labeling: a feasibility study Aherne, Emily A. Koktzoglou, Ioannis Lind, Benjamin B. Edelman, Robert R. J Cardiovasc Magn Reson Technical Notes BACKGROUND: Cine fast interrupted steady-state in combination with arterial spin labeling is a recently described nonenhanced magnetic resonance angiography (MRA) technique that relies on bolus tracking for time-resolved digital subtraction angiography-like displays of blood flow patterns. We evaluated the feasibility of applying this technique to display in-plane flow patterns in two regions: the abdominal aorta and lower extremity peripheral arteries. METHODS: We performed an institutional review board-approved study in healthy subjects and patients. In 7 healthy subjects, in-plane flow was imaged at 4 stations ranging from the lower legs to the aorto-iliac bifurcation (junction of the distal thigh and upper calf, mid-thigh, junction of the upper thigh and pelvis, upper pelvis). In 5 healthy subjects and 6 patients without abdominal aortopathy, images were acquired through the suprarenal abdominal aorta. Ten patients with known peripheral arterial disease and two patients with stable disease of the abdominal aorta were also evaluated. Peak velocity was compared at each of the 4 stations for cine fast interrupted steady-state in combination with arterial spin labeling and two-dimensional cine phase contrast in patients with normal vessels. RESULTS: In-plane flow patterns were well visualized in all peripheral arterial stations and in the abdominal aorta, providing a high quality display of hemodynamic patterns along extensive lengths of the vessels. There was very strong positive correlation (r = 0.952, P < 0.05) and excellent agreement (intraclass correlation coefficient, 0.935; 95% confidence interval, 0.812–0.972) between peak flow velocities measured by cine fast interrupted steady-state in combination with arterial spin labeling and two-dimensional cine phase contrast. In 10 patients with peripheral artery disease and 2 patients with aortic pathology, cine fast interrupted steady-state in combination with arterial spin labeling provided a visual demonstration of abnormal hemodynamics. CONCLUSION: This feasibility study suggests that cine fast interrupted steady-state in combination with arterial spin labeling provides an efficient, high quality and physiologically accurate display of in-plane flow patterns over extensive lengths of the lower extremity peripheral arteries, which can be difficult to achieve using other MRA techniques. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12968-019-0562-3) contains supplementary material, which is available to authorized users. BioMed Central 2019-09-02 /pmc/articles/PMC6717984/ /pubmed/31474219 http://dx.doi.org/10.1186/s12968-019-0562-3 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Technical Notes
Aherne, Emily A.
Koktzoglou, Ioannis
Lind, Benjamin B.
Edelman, Robert R.
Dynamic quantitative nonenhanced magnetic resonance angiography of the abdominal aorta and lower extremities using cine fast interrupted steady-state in combination with arterial spin labeling: a feasibility study
title Dynamic quantitative nonenhanced magnetic resonance angiography of the abdominal aorta and lower extremities using cine fast interrupted steady-state in combination with arterial spin labeling: a feasibility study
title_full Dynamic quantitative nonenhanced magnetic resonance angiography of the abdominal aorta and lower extremities using cine fast interrupted steady-state in combination with arterial spin labeling: a feasibility study
title_fullStr Dynamic quantitative nonenhanced magnetic resonance angiography of the abdominal aorta and lower extremities using cine fast interrupted steady-state in combination with arterial spin labeling: a feasibility study
title_full_unstemmed Dynamic quantitative nonenhanced magnetic resonance angiography of the abdominal aorta and lower extremities using cine fast interrupted steady-state in combination with arterial spin labeling: a feasibility study
title_short Dynamic quantitative nonenhanced magnetic resonance angiography of the abdominal aorta and lower extremities using cine fast interrupted steady-state in combination with arterial spin labeling: a feasibility study
title_sort dynamic quantitative nonenhanced magnetic resonance angiography of the abdominal aorta and lower extremities using cine fast interrupted steady-state in combination with arterial spin labeling: a feasibility study
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6717984/
https://www.ncbi.nlm.nih.gov/pubmed/31474219
http://dx.doi.org/10.1186/s12968-019-0562-3
work_keys_str_mv AT aherneemilya dynamicquantitativenonenhancedmagneticresonanceangiographyoftheabdominalaortaandlowerextremitiesusingcinefastinterruptedsteadystateincombinationwitharterialspinlabelingafeasibilitystudy
AT koktzoglouioannis dynamicquantitativenonenhancedmagneticresonanceangiographyoftheabdominalaortaandlowerextremitiesusingcinefastinterruptedsteadystateincombinationwitharterialspinlabelingafeasibilitystudy
AT lindbenjaminb dynamicquantitativenonenhancedmagneticresonanceangiographyoftheabdominalaortaandlowerextremitiesusingcinefastinterruptedsteadystateincombinationwitharterialspinlabelingafeasibilitystudy
AT edelmanrobertr dynamicquantitativenonenhancedmagneticresonanceangiographyoftheabdominalaortaandlowerextremitiesusingcinefastinterruptedsteadystateincombinationwitharterialspinlabelingafeasibilitystudy