Cargando…

Biomechanical comparison between standard and inclined screw orientation in dynamic hip screw side-plate fixation: The lift-off phenomenon

BACKGROUND: Common failure modes of dynamic hip screw are cut-out and lift-off. To minimize the latter, distal screws can be inserted in different orientations. However, the effectiveness remains controversial. The aim of this study was to biomechanically investigate the influence of distal screw or...

Descripción completa

Detalles Bibliográficos
Autores principales: Zderic, Ivan, Willhuber, Gaston C., Ahrend, Marc-Daniel, Gras, Florian, Barla, Jorge, Sancineto, Carlos, Windolf, Markus, Richards, Geoff, Gueorguiev, Boyko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Chinese Speaking Orthopaedic Society 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6718874/
https://www.ncbi.nlm.nih.gov/pubmed/31508312
http://dx.doi.org/10.1016/j.jot.2018.10.005
_version_ 1783447816813674496
author Zderic, Ivan
Willhuber, Gaston C.
Ahrend, Marc-Daniel
Gras, Florian
Barla, Jorge
Sancineto, Carlos
Windolf, Markus
Richards, Geoff
Gueorguiev, Boyko
author_facet Zderic, Ivan
Willhuber, Gaston C.
Ahrend, Marc-Daniel
Gras, Florian
Barla, Jorge
Sancineto, Carlos
Windolf, Markus
Richards, Geoff
Gueorguiev, Boyko
author_sort Zderic, Ivan
collection PubMed
description BACKGROUND: Common failure modes of dynamic hip screw are cut-out and lift-off. To minimize the latter, distal screws can be inserted in different orientations. However, the effectiveness remains controversial. The aim of this study was to biomechanically investigate the influence of distal screw orientation on construct stability. METHODS: Thirty artificial generic long bones were assigned to three groups (n = 10) and fixed with two-hole dynamic hip screw–plates, inserting distal cortical screws with neutral parallel screw orientation (A), divergent screw orientation (B) or convergent screw orientation (C). Starting at 60 N, cyclic loading was applied to the implant tip perpendicular to the lag screw axis with progressive peak load increase at a rate of 0.002 N/cycle until failure. Parameters of interest were construct stiffness and machine actuator displacement after 250, 1000 and 5000 cycles, as well as cycles to failure. RESULTS: Displacement after 250, 1000 and 5000 cycles was significantly higher in Group C than in Groups A and B, p < 0.01, whereas no significant differences were observed between Groups A and B, p = 0.20. Specimens in Group C failed after 11,584 [standard deviation (SD), 5924] cycles, significantly earlier than those in Groups A and B [A: 27,351 (SD, 12,509); B: 28,793 (SD, 14,764)], p ≤ 0.02. Cycles to failure were not significantly different between Groups A and B, p > 0.99. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: Parallel or divergent distal screw insertion provides similar construct stability in terms of resistance to plate lift-off. In contrast, converging screw insertion leads to inferior stability and is not advisable from a biomechanical point of view.
format Online
Article
Text
id pubmed-6718874
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Chinese Speaking Orthopaedic Society
record_format MEDLINE/PubMed
spelling pubmed-67188742019-09-10 Biomechanical comparison between standard and inclined screw orientation in dynamic hip screw side-plate fixation: The lift-off phenomenon Zderic, Ivan Willhuber, Gaston C. Ahrend, Marc-Daniel Gras, Florian Barla, Jorge Sancineto, Carlos Windolf, Markus Richards, Geoff Gueorguiev, Boyko J Orthop Translat Original Article BACKGROUND: Common failure modes of dynamic hip screw are cut-out and lift-off. To minimize the latter, distal screws can be inserted in different orientations. However, the effectiveness remains controversial. The aim of this study was to biomechanically investigate the influence of distal screw orientation on construct stability. METHODS: Thirty artificial generic long bones were assigned to three groups (n = 10) and fixed with two-hole dynamic hip screw–plates, inserting distal cortical screws with neutral parallel screw orientation (A), divergent screw orientation (B) or convergent screw orientation (C). Starting at 60 N, cyclic loading was applied to the implant tip perpendicular to the lag screw axis with progressive peak load increase at a rate of 0.002 N/cycle until failure. Parameters of interest were construct stiffness and machine actuator displacement after 250, 1000 and 5000 cycles, as well as cycles to failure. RESULTS: Displacement after 250, 1000 and 5000 cycles was significantly higher in Group C than in Groups A and B, p < 0.01, whereas no significant differences were observed between Groups A and B, p = 0.20. Specimens in Group C failed after 11,584 [standard deviation (SD), 5924] cycles, significantly earlier than those in Groups A and B [A: 27,351 (SD, 12,509); B: 28,793 (SD, 14,764)], p ≤ 0.02. Cycles to failure were not significantly different between Groups A and B, p > 0.99. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: Parallel or divergent distal screw insertion provides similar construct stability in terms of resistance to plate lift-off. In contrast, converging screw insertion leads to inferior stability and is not advisable from a biomechanical point of view. Chinese Speaking Orthopaedic Society 2018-11-17 /pmc/articles/PMC6718874/ /pubmed/31508312 http://dx.doi.org/10.1016/j.jot.2018.10.005 Text en © 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Zderic, Ivan
Willhuber, Gaston C.
Ahrend, Marc-Daniel
Gras, Florian
Barla, Jorge
Sancineto, Carlos
Windolf, Markus
Richards, Geoff
Gueorguiev, Boyko
Biomechanical comparison between standard and inclined screw orientation in dynamic hip screw side-plate fixation: The lift-off phenomenon
title Biomechanical comparison between standard and inclined screw orientation in dynamic hip screw side-plate fixation: The lift-off phenomenon
title_full Biomechanical comparison between standard and inclined screw orientation in dynamic hip screw side-plate fixation: The lift-off phenomenon
title_fullStr Biomechanical comparison between standard and inclined screw orientation in dynamic hip screw side-plate fixation: The lift-off phenomenon
title_full_unstemmed Biomechanical comparison between standard and inclined screw orientation in dynamic hip screw side-plate fixation: The lift-off phenomenon
title_short Biomechanical comparison between standard and inclined screw orientation in dynamic hip screw side-plate fixation: The lift-off phenomenon
title_sort biomechanical comparison between standard and inclined screw orientation in dynamic hip screw side-plate fixation: the lift-off phenomenon
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6718874/
https://www.ncbi.nlm.nih.gov/pubmed/31508312
http://dx.doi.org/10.1016/j.jot.2018.10.005
work_keys_str_mv AT zdericivan biomechanicalcomparisonbetweenstandardandinclinedscreworientationindynamichipscrewsideplatefixationtheliftoffphenomenon
AT willhubergastonc biomechanicalcomparisonbetweenstandardandinclinedscreworientationindynamichipscrewsideplatefixationtheliftoffphenomenon
AT ahrendmarcdaniel biomechanicalcomparisonbetweenstandardandinclinedscreworientationindynamichipscrewsideplatefixationtheliftoffphenomenon
AT grasflorian biomechanicalcomparisonbetweenstandardandinclinedscreworientationindynamichipscrewsideplatefixationtheliftoffphenomenon
AT barlajorge biomechanicalcomparisonbetweenstandardandinclinedscreworientationindynamichipscrewsideplatefixationtheliftoffphenomenon
AT sancinetocarlos biomechanicalcomparisonbetweenstandardandinclinedscreworientationindynamichipscrewsideplatefixationtheliftoffphenomenon
AT windolfmarkus biomechanicalcomparisonbetweenstandardandinclinedscreworientationindynamichipscrewsideplatefixationtheliftoffphenomenon
AT richardsgeoff biomechanicalcomparisonbetweenstandardandinclinedscreworientationindynamichipscrewsideplatefixationtheliftoffphenomenon
AT gueorguievboyko biomechanicalcomparisonbetweenstandardandinclinedscreworientationindynamichipscrewsideplatefixationtheliftoffphenomenon