Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy

One of the most common means for diagnosis is through medical laboratory testing, which primarily uses venous blood as a sample. This requires an invasive method by cannulation that needs proper vein selection. The use of a vein finder would help the phlebotomist to easily locate the vein, preventin...

Descripción completa

Detalles Bibliográficos
Autores principales: Pan, Cheng-Tang, Francisco, Mark D., Yen, Chung-Kun, Wang, Shao-Yu, Shiue, Yow-Ling
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6719195/
https://www.ncbi.nlm.nih.gov/pubmed/31426370
http://dx.doi.org/10.3390/s19163573
_version_ 1783447886209482752
author Pan, Cheng-Tang
Francisco, Mark D.
Yen, Chung-Kun
Wang, Shao-Yu
Shiue, Yow-Ling
author_facet Pan, Cheng-Tang
Francisco, Mark D.
Yen, Chung-Kun
Wang, Shao-Yu
Shiue, Yow-Ling
author_sort Pan, Cheng-Tang
collection PubMed
description One of the most common means for diagnosis is through medical laboratory testing, which primarily uses venous blood as a sample. This requires an invasive method by cannulation that needs proper vein selection. The use of a vein finder would help the phlebotomist to easily locate the vein, preventing possible pre-analytical error in the specimen collection and even more discomfort and pain to the patient. This paper is a review of the scientific publications on the different developed low-cost vein finder prototypes utilizing camera assisted near infrared (NIR) light technology. Methods: Electronic databases were searched online, these included PubMed (PMC), MEDLINE, Science Direct, ResearchGate, and Institute of Electrical and Electronics Engineers (IEEE) Xplore digital library. Specifically, publications with the terms vein finder prototype, NIR technology, vein detection, and infrared imaging were screened. In addition, reference lists were used to further review related publications. Results: Cannulation challenges medical practitioners because of the different factors that can be reduced by the utilization of a vein finder. A limited number of publications regarding the assessment of personnel performing cannulation were observed. Moreover, variations in methodology, number of patients, type of patients according to their demographics and materials used in the assessment of the developed prototypes were noted. Some studies were limited with regard to the actual human testing of the prototype. Conclusions: The development of a low-cost effective near infrared (NIR) vein finder remains in the phase of improvement. Since, it is being challenged by different human factors, increasing the number of parameters and participants/human for actual testing of the prototypes must also be taken into consideration for possible commercialization. Finally, it was noted that publications regarding the assessment of the performance of phlebotomists using vein finders were limited.
format Online
Article
Text
id pubmed-6719195
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-67191952019-09-10 Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy Pan, Cheng-Tang Francisco, Mark D. Yen, Chung-Kun Wang, Shao-Yu Shiue, Yow-Ling Sensors (Basel) Review One of the most common means for diagnosis is through medical laboratory testing, which primarily uses venous blood as a sample. This requires an invasive method by cannulation that needs proper vein selection. The use of a vein finder would help the phlebotomist to easily locate the vein, preventing possible pre-analytical error in the specimen collection and even more discomfort and pain to the patient. This paper is a review of the scientific publications on the different developed low-cost vein finder prototypes utilizing camera assisted near infrared (NIR) light technology. Methods: Electronic databases were searched online, these included PubMed (PMC), MEDLINE, Science Direct, ResearchGate, and Institute of Electrical and Electronics Engineers (IEEE) Xplore digital library. Specifically, publications with the terms vein finder prototype, NIR technology, vein detection, and infrared imaging were screened. In addition, reference lists were used to further review related publications. Results: Cannulation challenges medical practitioners because of the different factors that can be reduced by the utilization of a vein finder. A limited number of publications regarding the assessment of personnel performing cannulation were observed. Moreover, variations in methodology, number of patients, type of patients according to their demographics and materials used in the assessment of the developed prototypes were noted. Some studies were limited with regard to the actual human testing of the prototype. Conclusions: The development of a low-cost effective near infrared (NIR) vein finder remains in the phase of improvement. Since, it is being challenged by different human factors, increasing the number of parameters and participants/human for actual testing of the prototypes must also be taken into consideration for possible commercialization. Finally, it was noted that publications regarding the assessment of the performance of phlebotomists using vein finders were limited. MDPI 2019-08-16 /pmc/articles/PMC6719195/ /pubmed/31426370 http://dx.doi.org/10.3390/s19163573 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Pan, Cheng-Tang
Francisco, Mark D.
Yen, Chung-Kun
Wang, Shao-Yu
Shiue, Yow-Ling
Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy
title Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy
title_full Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy
title_fullStr Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy
title_full_unstemmed Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy
title_short Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy
title_sort vein pattern locating technology for cannulation: a review of the low-cost vein finder prototypes utilizing near infrared (nir) light to improve peripheral subcutaneous vein selection for phlebotomy
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6719195/
https://www.ncbi.nlm.nih.gov/pubmed/31426370
http://dx.doi.org/10.3390/s19163573
work_keys_str_mv AT panchengtang veinpatternlocatingtechnologyforcannulationareviewofthelowcostveinfinderprototypesutilizingnearinfrarednirlighttoimproveperipheralsubcutaneousveinselectionforphlebotomy
AT franciscomarkd veinpatternlocatingtechnologyforcannulationareviewofthelowcostveinfinderprototypesutilizingnearinfrarednirlighttoimproveperipheralsubcutaneousveinselectionforphlebotomy
AT yenchungkun veinpatternlocatingtechnologyforcannulationareviewofthelowcostveinfinderprototypesutilizingnearinfrarednirlighttoimproveperipheralsubcutaneousveinselectionforphlebotomy
AT wangshaoyu veinpatternlocatingtechnologyforcannulationareviewofthelowcostveinfinderprototypesutilizingnearinfrarednirlighttoimproveperipheralsubcutaneousveinselectionforphlebotomy
AT shiueyowling veinpatternlocatingtechnologyforcannulationareviewofthelowcostveinfinderprototypesutilizingnearinfrarednirlighttoimproveperipheralsubcutaneousveinselectionforphlebotomy