Cargando…
The road from intermittently scanned continuous glucose monitoring to hybrid closed-loop systems. Part B: results from randomized controlled trials
BACKGROUND: Advances in diabetes technology have been exponential in the last few decades. With evolution in continuous glucose monitoring (CGM) systems and its progressive automation in control of insulin delivery, these advances have changed type 1 diabetes mellitus (T1DM) management. These novel...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6719474/ https://www.ncbi.nlm.nih.gov/pubmed/31516690 http://dx.doi.org/10.1177/2042018819871903 |
_version_ | 1783447942781206528 |
---|---|
author | De Ridder, Francesca den Brinker, Marieke De Block, Christophe |
author_facet | De Ridder, Francesca den Brinker, Marieke De Block, Christophe |
author_sort | De Ridder, Francesca |
collection | PubMed |
description | BACKGROUND: Advances in diabetes technology have been exponential in the last few decades. With evolution in continuous glucose monitoring (CGM) systems and its progressive automation in control of insulin delivery, these advances have changed type 1 diabetes mellitus (T1DM) management. These novel technologies have the potential to improve glycated haemoglobin (HbA1c), reduce hypoglycaemic events, increase time spent in range and improve quality of life (QoL). Our aim was to evaluate the sustained effects in free-living unsupervised conditions of CGM systems (intermittently scanned and real time) and insulin delivery [from multiple daily injections, via sensor-augmented pump therapy and (predictive) low-glucose insulin suspension to hybrid closed-loop systems] on glucose control and QoL in adults and children with T1DM. METHODS: We performed a systematic review of randomized controlled trials (RCTs), using PubMed and the Cochrane library up to 30 May 2019. Inclusion of RCTs was based on type of intervention (comparing glucose-monitoring devices and insulin-delivery devices), population (nonpregnant adults and children with T1DM), follow-up (outpatient setting for at least 8 weeks) and relevant outcomes [HbA1c, time in range (TIR), time in target, time in hypoglycaemia and QoL]. Exclusion of RCTs was based on intervention (exercise, only overnight use). The Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines were used to score the quality of the papers and for the final selection of the articles. RESULTS: Our search resulted in 214 articles, of which 19 were eligible. Studies on advanced use in adults and children with T1DM reported increased TIR (all 9 studies); decreased time in hypoglycaemia (13 out of 15 studies); lowered HbA1c levels (5 out of 15 studies); improved QoL (10 of 16 studies) and treatment satisfaction (7 studies). CONCLUSIONS: Recent technologies have dramatically changed the course of T1DM. They are proving useful in controlling glycaemia in patients with T1DM, without increasing the treatment burden. |
format | Online Article Text |
id | pubmed-6719474 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-67194742019-09-12 The road from intermittently scanned continuous glucose monitoring to hybrid closed-loop systems. Part B: results from randomized controlled trials De Ridder, Francesca den Brinker, Marieke De Block, Christophe Ther Adv Endocrinol Metab Systematic Review BACKGROUND: Advances in diabetes technology have been exponential in the last few decades. With evolution in continuous glucose monitoring (CGM) systems and its progressive automation in control of insulin delivery, these advances have changed type 1 diabetes mellitus (T1DM) management. These novel technologies have the potential to improve glycated haemoglobin (HbA1c), reduce hypoglycaemic events, increase time spent in range and improve quality of life (QoL). Our aim was to evaluate the sustained effects in free-living unsupervised conditions of CGM systems (intermittently scanned and real time) and insulin delivery [from multiple daily injections, via sensor-augmented pump therapy and (predictive) low-glucose insulin suspension to hybrid closed-loop systems] on glucose control and QoL in adults and children with T1DM. METHODS: We performed a systematic review of randomized controlled trials (RCTs), using PubMed and the Cochrane library up to 30 May 2019. Inclusion of RCTs was based on type of intervention (comparing glucose-monitoring devices and insulin-delivery devices), population (nonpregnant adults and children with T1DM), follow-up (outpatient setting for at least 8 weeks) and relevant outcomes [HbA1c, time in range (TIR), time in target, time in hypoglycaemia and QoL]. Exclusion of RCTs was based on intervention (exercise, only overnight use). The Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines were used to score the quality of the papers and for the final selection of the articles. RESULTS: Our search resulted in 214 articles, of which 19 were eligible. Studies on advanced use in adults and children with T1DM reported increased TIR (all 9 studies); decreased time in hypoglycaemia (13 out of 15 studies); lowered HbA1c levels (5 out of 15 studies); improved QoL (10 of 16 studies) and treatment satisfaction (7 studies). CONCLUSIONS: Recent technologies have dramatically changed the course of T1DM. They are proving useful in controlling glycaemia in patients with T1DM, without increasing the treatment burden. SAGE Publications 2019-08-30 /pmc/articles/PMC6719474/ /pubmed/31516690 http://dx.doi.org/10.1177/2042018819871903 Text en © The Author(s), 2019 http://www.creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Systematic Review De Ridder, Francesca den Brinker, Marieke De Block, Christophe The road from intermittently scanned continuous glucose monitoring to hybrid closed-loop systems. Part B: results from randomized controlled trials |
title | The road from intermittently scanned continuous glucose monitoring to hybrid closed-loop systems. Part B: results from randomized controlled trials |
title_full | The road from intermittently scanned continuous glucose monitoring to hybrid closed-loop systems. Part B: results from randomized controlled trials |
title_fullStr | The road from intermittently scanned continuous glucose monitoring to hybrid closed-loop systems. Part B: results from randomized controlled trials |
title_full_unstemmed | The road from intermittently scanned continuous glucose monitoring to hybrid closed-loop systems. Part B: results from randomized controlled trials |
title_short | The road from intermittently scanned continuous glucose monitoring to hybrid closed-loop systems. Part B: results from randomized controlled trials |
title_sort | road from intermittently scanned continuous glucose monitoring to hybrid closed-loop systems. part b: results from randomized controlled trials |
topic | Systematic Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6719474/ https://www.ncbi.nlm.nih.gov/pubmed/31516690 http://dx.doi.org/10.1177/2042018819871903 |
work_keys_str_mv | AT deridderfrancesca theroadfromintermittentlyscannedcontinuousglucosemonitoringtohybridclosedloopsystemspartbresultsfromrandomizedcontrolledtrials AT denbrinkermarieke theroadfromintermittentlyscannedcontinuousglucosemonitoringtohybridclosedloopsystemspartbresultsfromrandomizedcontrolledtrials AT deblockchristophe theroadfromintermittentlyscannedcontinuousglucosemonitoringtohybridclosedloopsystemspartbresultsfromrandomizedcontrolledtrials AT deridderfrancesca roadfromintermittentlyscannedcontinuousglucosemonitoringtohybridclosedloopsystemspartbresultsfromrandomizedcontrolledtrials AT denbrinkermarieke roadfromintermittentlyscannedcontinuousglucosemonitoringtohybridclosedloopsystemspartbresultsfromrandomizedcontrolledtrials AT deblockchristophe roadfromintermittentlyscannedcontinuousglucosemonitoringtohybridclosedloopsystemspartbresultsfromrandomizedcontrolledtrials |