Cargando…
Case Report: Pulmonary hemorrhage as a rare cause of lung ultrasound A/B-profile
When using lung ultrasound to determine the cause of acute respiratory failure, the BLUE protocol is often used. In a 65-year old patient, an A/B-profile was found, suggesting pneumonia, following the flowchart of this protocol. In this case, however, pulmonary hemorrhage confirmed by bronchoscopy w...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
F1000 Research Limited
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6720040/ https://www.ncbi.nlm.nih.gov/pubmed/31508213 http://dx.doi.org/10.12688/f1000research.19329.2 |
Sumario: | When using lung ultrasound to determine the cause of acute respiratory failure, the BLUE protocol is often used. In a 65-year old patient, an A/B-profile was found, suggesting pneumonia, following the flowchart of this protocol. In this case, however, pulmonary hemorrhage confirmed by bronchoscopy was the final diagnosis. This case report outlines the importance of understanding the limitations of the BLUE protocol and that lung ultrasound findings should always be used in the context of the patient’s history and physical exam. In addition, pulmonary hemorrhage should be considered in patients with no clinical signs of pneumonia and/or presence of risk factors for lung bleeding as a rare cause of lung ultrasound A/B-profile. |
---|