Cargando…
Comparison of Active Electrode Materials for Non-Contact ECG Measurement
For long-term and more convenience electrocardiograph (ECG) monitoring, an active- electrode-based ECG monitoring system, which can measure ECG through clothes, is proposed in this paper. The hardware of the system includes active electrodes, signal processing and data transmission modules and the s...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6720752/ https://www.ncbi.nlm.nih.gov/pubmed/31426518 http://dx.doi.org/10.3390/s19163585 |
_version_ | 1783448197961613312 |
---|---|
author | Peng, Shun Xu, Ke Chen, Wei |
author_facet | Peng, Shun Xu, Ke Chen, Wei |
author_sort | Peng, Shun |
collection | PubMed |
description | For long-term and more convenience electrocardiograph (ECG) monitoring, an active- electrode-based ECG monitoring system, which can measure ECG through clothes, is proposed in this paper. The hardware of the system includes active electrodes, signal processing and data transmission modules and the software mainly includes a denoising algorithm based on empirical mode decomposition (EMD). Then the proposed system was verified using the comparison of the ECG signals measured synchronously by active electrodes and Ag/AgCl electrodes. In addition, three flexible materials, including conductive textile, copper foil tape and a flexible printed circuit (FPC) are developed for the sensing layer with active electrodes. To compare the performance of these three materials for the sensing layer, the ECG signals of 10 subjects were measured by different materials in three postures and several indexes for quality evaluation were calculated. Results show that effective and clear ECG waveforms can be measured by all three kinds of materials and the quality of ECG signals measured by FPC is the best by conducting a significant t-test for signal quality indexes of three materials. |
format | Online Article Text |
id | pubmed-6720752 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-67207522019-09-10 Comparison of Active Electrode Materials for Non-Contact ECG Measurement Peng, Shun Xu, Ke Chen, Wei Sensors (Basel) Article For long-term and more convenience electrocardiograph (ECG) monitoring, an active- electrode-based ECG monitoring system, which can measure ECG through clothes, is proposed in this paper. The hardware of the system includes active electrodes, signal processing and data transmission modules and the software mainly includes a denoising algorithm based on empirical mode decomposition (EMD). Then the proposed system was verified using the comparison of the ECG signals measured synchronously by active electrodes and Ag/AgCl electrodes. In addition, three flexible materials, including conductive textile, copper foil tape and a flexible printed circuit (FPC) are developed for the sensing layer with active electrodes. To compare the performance of these three materials for the sensing layer, the ECG signals of 10 subjects were measured by different materials in three postures and several indexes for quality evaluation were calculated. Results show that effective and clear ECG waveforms can be measured by all three kinds of materials and the quality of ECG signals measured by FPC is the best by conducting a significant t-test for signal quality indexes of three materials. MDPI 2019-08-17 /pmc/articles/PMC6720752/ /pubmed/31426518 http://dx.doi.org/10.3390/s19163585 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Peng, Shun Xu, Ke Chen, Wei Comparison of Active Electrode Materials for Non-Contact ECG Measurement |
title | Comparison of Active Electrode Materials for Non-Contact ECG Measurement |
title_full | Comparison of Active Electrode Materials for Non-Contact ECG Measurement |
title_fullStr | Comparison of Active Electrode Materials for Non-Contact ECG Measurement |
title_full_unstemmed | Comparison of Active Electrode Materials for Non-Contact ECG Measurement |
title_short | Comparison of Active Electrode Materials for Non-Contact ECG Measurement |
title_sort | comparison of active electrode materials for non-contact ecg measurement |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6720752/ https://www.ncbi.nlm.nih.gov/pubmed/31426518 http://dx.doi.org/10.3390/s19163585 |
work_keys_str_mv | AT pengshun comparisonofactiveelectrodematerialsfornoncontactecgmeasurement AT xuke comparisonofactiveelectrodematerialsfornoncontactecgmeasurement AT chenwei comparisonofactiveelectrodematerialsfornoncontactecgmeasurement |