Cargando…

Determination of Odor Intensity of Binary Gas Mixtures Using Perceptual Models and an Electronic Nose Combined with Fuzzy Logic

Measurement and monitoring of air quality in terms of odor nuisance is an important problem. From a practical point of view, it would be most valuable to directly link the odor intensity with the results of analytical air monitoring. Such a solution is offered by electronic noses, which thanks to th...

Descripción completa

Detalles Bibliográficos
Autores principales: Szulczyński, Bartosz, Gębicki, Jacek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6720763/
https://www.ncbi.nlm.nih.gov/pubmed/31398955
http://dx.doi.org/10.3390/s19163473
_version_ 1783448200338735104
author Szulczyński, Bartosz
Gębicki, Jacek
author_facet Szulczyński, Bartosz
Gębicki, Jacek
author_sort Szulczyński, Bartosz
collection PubMed
description Measurement and monitoring of air quality in terms of odor nuisance is an important problem. From a practical point of view, it would be most valuable to directly link the odor intensity with the results of analytical air monitoring. Such a solution is offered by electronic noses, which thanks to the possibility of holistic analysis of the gas sample, allow estimation of the odor intensity of the gas mixture. The biggest problem is the occurrence of odor interactions between the mixture components. For this reason, methods that can take into account the interaction between components of the mixture are used to analyze data from the e-nose. In the presented study, the fuzzy logic algorithm was proposed for determination of odor intensity of binary mixtures of eight odorants: n-Hexane, cyclohexane, toluene, o-xylene, trimethylamine, triethylamine, α-pinene, and β-pinene. The proposed algorithm was compared with four theoretical perceptual models: Euclidean additivity, vectorial additivity, U model, and UPL model.
format Online
Article
Text
id pubmed-6720763
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-67207632019-09-10 Determination of Odor Intensity of Binary Gas Mixtures Using Perceptual Models and an Electronic Nose Combined with Fuzzy Logic Szulczyński, Bartosz Gębicki, Jacek Sensors (Basel) Article Measurement and monitoring of air quality in terms of odor nuisance is an important problem. From a practical point of view, it would be most valuable to directly link the odor intensity with the results of analytical air monitoring. Such a solution is offered by electronic noses, which thanks to the possibility of holistic analysis of the gas sample, allow estimation of the odor intensity of the gas mixture. The biggest problem is the occurrence of odor interactions between the mixture components. For this reason, methods that can take into account the interaction between components of the mixture are used to analyze data from the e-nose. In the presented study, the fuzzy logic algorithm was proposed for determination of odor intensity of binary mixtures of eight odorants: n-Hexane, cyclohexane, toluene, o-xylene, trimethylamine, triethylamine, α-pinene, and β-pinene. The proposed algorithm was compared with four theoretical perceptual models: Euclidean additivity, vectorial additivity, U model, and UPL model. MDPI 2019-08-08 /pmc/articles/PMC6720763/ /pubmed/31398955 http://dx.doi.org/10.3390/s19163473 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Szulczyński, Bartosz
Gębicki, Jacek
Determination of Odor Intensity of Binary Gas Mixtures Using Perceptual Models and an Electronic Nose Combined with Fuzzy Logic
title Determination of Odor Intensity of Binary Gas Mixtures Using Perceptual Models and an Electronic Nose Combined with Fuzzy Logic
title_full Determination of Odor Intensity of Binary Gas Mixtures Using Perceptual Models and an Electronic Nose Combined with Fuzzy Logic
title_fullStr Determination of Odor Intensity of Binary Gas Mixtures Using Perceptual Models and an Electronic Nose Combined with Fuzzy Logic
title_full_unstemmed Determination of Odor Intensity of Binary Gas Mixtures Using Perceptual Models and an Electronic Nose Combined with Fuzzy Logic
title_short Determination of Odor Intensity of Binary Gas Mixtures Using Perceptual Models and an Electronic Nose Combined with Fuzzy Logic
title_sort determination of odor intensity of binary gas mixtures using perceptual models and an electronic nose combined with fuzzy logic
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6720763/
https://www.ncbi.nlm.nih.gov/pubmed/31398955
http://dx.doi.org/10.3390/s19163473
work_keys_str_mv AT szulczynskibartosz determinationofodorintensityofbinarygasmixturesusingperceptualmodelsandanelectronicnosecombinedwithfuzzylogic
AT gebickijacek determinationofodorintensityofbinarygasmixturesusingperceptualmodelsandanelectronicnosecombinedwithfuzzylogic