Cargando…

Finite Element- and Design of Experiment-Derived Optimization of Screw Configurations and a Locking Plate for Internal Fixation System

OBJECTIVES: The optimization for the screw configurations and bone plate parameters was studied to improve the biomechanical performances such as reliable internal fixation and beneficial callus growth for the clinical treatment of femoral shaft fracture. METHODS: The finite element analysis (FEA) o...

Descripción completa

Detalles Bibliográficos
Autores principales: Sheng, Wei, Ji, Aimin, Fang, Runxin, He, Gang, Chen, Changsheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6721095/
https://www.ncbi.nlm.nih.gov/pubmed/31531124
http://dx.doi.org/10.1155/2019/5636528
_version_ 1783448269547896832
author Sheng, Wei
Ji, Aimin
Fang, Runxin
He, Gang
Chen, Changsheng
author_facet Sheng, Wei
Ji, Aimin
Fang, Runxin
He, Gang
Chen, Changsheng
author_sort Sheng, Wei
collection PubMed
description OBJECTIVES: The optimization for the screw configurations and bone plate parameters was studied to improve the biomechanical performances such as reliable internal fixation and beneficial callus growth for the clinical treatment of femoral shaft fracture. METHODS: The finite element analysis (FEA) of internal fixation system under different screw configurations based on the orthogonal design was performed and so was for the different structural parameters of the locking plate based on the combination of uniform and orthogonal design. Moreover, orthogonal experiment weight matrixes for four evaluation indexes with FEA were analyzed. RESULTS: The analytical results showed the optimal scheme of screw configuration was that screws are omitted in the thread holes near the fracture site, and single cortical screws are used in the following holes to the distal end, while the double cortical screws are fixed in thread holes that are distal to the fracture; in the other words, the length of the screws showed an increasing trend from the fracture site to the distal end in the optimized configuration. The plate structure was optimized when thread holes gap reached 13 mm, with a width of 11 mm and 4.6 mm and 5 mm for thickness and diameter of the screw, respectively. The biomechanical performance of the internal fixation construct was further improved by about 10% based on the optimal strain range and lower stress in the internal fixation system. CONCLUSIONS: The proposed orthogonal design and uniform design can be used in a more efficient way for the optimization of internal fixation system, which can reduce the simulation runs to about 10% compared with comprehensive test, and the methodology can be also used for other types of fractures to achieve better internal fixation stability and optimal healing efficiency, which may provide a method for an orthopedist in choosing the screw configurations and parameters for internal fixation system in a more efficient way.
format Online
Article
Text
id pubmed-6721095
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-67210952019-09-17 Finite Element- and Design of Experiment-Derived Optimization of Screw Configurations and a Locking Plate for Internal Fixation System Sheng, Wei Ji, Aimin Fang, Runxin He, Gang Chen, Changsheng Comput Math Methods Med Research Article OBJECTIVES: The optimization for the screw configurations and bone plate parameters was studied to improve the biomechanical performances such as reliable internal fixation and beneficial callus growth for the clinical treatment of femoral shaft fracture. METHODS: The finite element analysis (FEA) of internal fixation system under different screw configurations based on the orthogonal design was performed and so was for the different structural parameters of the locking plate based on the combination of uniform and orthogonal design. Moreover, orthogonal experiment weight matrixes for four evaluation indexes with FEA were analyzed. RESULTS: The analytical results showed the optimal scheme of screw configuration was that screws are omitted in the thread holes near the fracture site, and single cortical screws are used in the following holes to the distal end, while the double cortical screws are fixed in thread holes that are distal to the fracture; in the other words, the length of the screws showed an increasing trend from the fracture site to the distal end in the optimized configuration. The plate structure was optimized when thread holes gap reached 13 mm, with a width of 11 mm and 4.6 mm and 5 mm for thickness and diameter of the screw, respectively. The biomechanical performance of the internal fixation construct was further improved by about 10% based on the optimal strain range and lower stress in the internal fixation system. CONCLUSIONS: The proposed orthogonal design and uniform design can be used in a more efficient way for the optimization of internal fixation system, which can reduce the simulation runs to about 10% compared with comprehensive test, and the methodology can be also used for other types of fractures to achieve better internal fixation stability and optimal healing efficiency, which may provide a method for an orthopedist in choosing the screw configurations and parameters for internal fixation system in a more efficient way. Hindawi 2019-08-21 /pmc/articles/PMC6721095/ /pubmed/31531124 http://dx.doi.org/10.1155/2019/5636528 Text en Copyright © 2019 Wei Sheng et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Sheng, Wei
Ji, Aimin
Fang, Runxin
He, Gang
Chen, Changsheng
Finite Element- and Design of Experiment-Derived Optimization of Screw Configurations and a Locking Plate for Internal Fixation System
title Finite Element- and Design of Experiment-Derived Optimization of Screw Configurations and a Locking Plate for Internal Fixation System
title_full Finite Element- and Design of Experiment-Derived Optimization of Screw Configurations and a Locking Plate for Internal Fixation System
title_fullStr Finite Element- and Design of Experiment-Derived Optimization of Screw Configurations and a Locking Plate for Internal Fixation System
title_full_unstemmed Finite Element- and Design of Experiment-Derived Optimization of Screw Configurations and a Locking Plate for Internal Fixation System
title_short Finite Element- and Design of Experiment-Derived Optimization of Screw Configurations and a Locking Plate for Internal Fixation System
title_sort finite element- and design of experiment-derived optimization of screw configurations and a locking plate for internal fixation system
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6721095/
https://www.ncbi.nlm.nih.gov/pubmed/31531124
http://dx.doi.org/10.1155/2019/5636528
work_keys_str_mv AT shengwei finiteelementanddesignofexperimentderivedoptimizationofscrewconfigurationsandalockingplateforinternalfixationsystem
AT jiaimin finiteelementanddesignofexperimentderivedoptimizationofscrewconfigurationsandalockingplateforinternalfixationsystem
AT fangrunxin finiteelementanddesignofexperimentderivedoptimizationofscrewconfigurationsandalockingplateforinternalfixationsystem
AT hegang finiteelementanddesignofexperimentderivedoptimizationofscrewconfigurationsandalockingplateforinternalfixationsystem
AT chenchangsheng finiteelementanddesignofexperimentderivedoptimizationofscrewconfigurationsandalockingplateforinternalfixationsystem