Cargando…

3D Printed Lab-on-a-Chip Platform for Chemical Stimulation and Parallel Analysis of Ion Channel Function

Functional imaging has been a widely established method for the assessment of ion channel function in vitro. Conventional infrastructure used for in vitro functional analysis of ion channels is typically proprietary, non-customizable, expensive, and requires a high level of skill to use and maintain...

Descripción completa

Detalles Bibliográficos
Autores principales: Aschenbrenner, Daniel, Friedrich, Oliver, Gilbert, Daniel F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6722671/
https://www.ncbi.nlm.nih.gov/pubmed/31430884
http://dx.doi.org/10.3390/mi10080548
_version_ 1783448592392912896
author Aschenbrenner, Daniel
Friedrich, Oliver
Gilbert, Daniel F.
author_facet Aschenbrenner, Daniel
Friedrich, Oliver
Gilbert, Daniel F.
author_sort Aschenbrenner, Daniel
collection PubMed
description Functional imaging has been a widely established method for the assessment of ion channel function in vitro. Conventional infrastructure used for in vitro functional analysis of ion channels is typically proprietary, non-customizable, expensive, and requires a high level of skill to use and maintain. 3D desktop printing, which is employed in the rapid prototyping field, allows for quick engineering of alternatives to conventional imaging infrastructure that are customizable, low cost, and user friendly. Here, we describe an ultra-low-cost microfluidic lab-on-a-chip (LOC) device manufactured using acrylonitrile butadiene styrene (ABS) for in vitro functional imaging of ion channels that can quickly and easily be reconstructed using three-dimensional (3D) desktop printing. The device is light weight (<5 g), small (20 mm × 49 mm), and extremely low cost (<EUR 1). We simulate fluidics within the printed channels and assess the suitability of the engineered chamber to generate homogeneous mixtures during solution exchange. We demonstrate the usability of the 3D printed microfluidic device in a case study using Fluo-4-loaded human embryonal kidney-derived (HEK293) cells, recombinantly expressing the capsaicin receptor, transient receptor potential vanilloid receptor type 1 (TRPV1), as a model system. In the case study, we confirm its applicability to solution exchange for chemical stimulation and parallel functional time-lapse fluorescence microscopy-based calcium imaging. We assess the suitability of ABS for culturing HEK293 cells inside the microfluidic LOC, based on qualitative analysis of microscopic transmission light images of ABS-exposed HEK293 cells and confirm the previously reported biocompatibility of ABS. To highlight the versatility of the 3D printed microfluidic device, we provide an example for multiplication of the shown concept within a 3D printed multichannel microfluidic LOC to be used, for example, in a higher throughput format for parallelized functional analysis of ion channels. While this work focusses on Ca(2+) imaging with TRPV1 channels, the device may also be useful for application with other ion channel types and in vitro models.
format Online
Article
Text
id pubmed-6722671
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-67226712019-09-10 3D Printed Lab-on-a-Chip Platform for Chemical Stimulation and Parallel Analysis of Ion Channel Function Aschenbrenner, Daniel Friedrich, Oliver Gilbert, Daniel F. Micromachines (Basel) Article Functional imaging has been a widely established method for the assessment of ion channel function in vitro. Conventional infrastructure used for in vitro functional analysis of ion channels is typically proprietary, non-customizable, expensive, and requires a high level of skill to use and maintain. 3D desktop printing, which is employed in the rapid prototyping field, allows for quick engineering of alternatives to conventional imaging infrastructure that are customizable, low cost, and user friendly. Here, we describe an ultra-low-cost microfluidic lab-on-a-chip (LOC) device manufactured using acrylonitrile butadiene styrene (ABS) for in vitro functional imaging of ion channels that can quickly and easily be reconstructed using three-dimensional (3D) desktop printing. The device is light weight (<5 g), small (20 mm × 49 mm), and extremely low cost (<EUR 1). We simulate fluidics within the printed channels and assess the suitability of the engineered chamber to generate homogeneous mixtures during solution exchange. We demonstrate the usability of the 3D printed microfluidic device in a case study using Fluo-4-loaded human embryonal kidney-derived (HEK293) cells, recombinantly expressing the capsaicin receptor, transient receptor potential vanilloid receptor type 1 (TRPV1), as a model system. In the case study, we confirm its applicability to solution exchange for chemical stimulation and parallel functional time-lapse fluorescence microscopy-based calcium imaging. We assess the suitability of ABS for culturing HEK293 cells inside the microfluidic LOC, based on qualitative analysis of microscopic transmission light images of ABS-exposed HEK293 cells and confirm the previously reported biocompatibility of ABS. To highlight the versatility of the 3D printed microfluidic device, we provide an example for multiplication of the shown concept within a 3D printed multichannel microfluidic LOC to be used, for example, in a higher throughput format for parallelized functional analysis of ion channels. While this work focusses on Ca(2+) imaging with TRPV1 channels, the device may also be useful for application with other ion channel types and in vitro models. MDPI 2019-08-19 /pmc/articles/PMC6722671/ /pubmed/31430884 http://dx.doi.org/10.3390/mi10080548 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Aschenbrenner, Daniel
Friedrich, Oliver
Gilbert, Daniel F.
3D Printed Lab-on-a-Chip Platform for Chemical Stimulation and Parallel Analysis of Ion Channel Function
title 3D Printed Lab-on-a-Chip Platform for Chemical Stimulation and Parallel Analysis of Ion Channel Function
title_full 3D Printed Lab-on-a-Chip Platform for Chemical Stimulation and Parallel Analysis of Ion Channel Function
title_fullStr 3D Printed Lab-on-a-Chip Platform for Chemical Stimulation and Parallel Analysis of Ion Channel Function
title_full_unstemmed 3D Printed Lab-on-a-Chip Platform for Chemical Stimulation and Parallel Analysis of Ion Channel Function
title_short 3D Printed Lab-on-a-Chip Platform for Chemical Stimulation and Parallel Analysis of Ion Channel Function
title_sort 3d printed lab-on-a-chip platform for chemical stimulation and parallel analysis of ion channel function
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6722671/
https://www.ncbi.nlm.nih.gov/pubmed/31430884
http://dx.doi.org/10.3390/mi10080548
work_keys_str_mv AT aschenbrennerdaniel 3dprintedlabonachipplatformforchemicalstimulationandparallelanalysisofionchannelfunction
AT friedricholiver 3dprintedlabonachipplatformforchemicalstimulationandparallelanalysisofionchannelfunction
AT gilbertdanielf 3dprintedlabonachipplatformforchemicalstimulationandparallelanalysisofionchannelfunction