Cargando…

Intraosseous Temperature Change during Installation of Dental Implants with Two Different Surfaces and Different Drilling Protocols: An In Vivo Study in Sheep

Background: The intraosseous temperature during implant installation has never been evaluated in an in vivo controlled setup. The aims were to investigate the influence of a drilling protocol and implant surface on the intraosseous temperature during implant installation, to evaluate the influence o...

Descripción completa

Detalles Bibliográficos
Autores principales: Stocchero, Michele, Jinno, Yohei, Toia, Marco, Ahmad, Marianne, Papia, Evaggelia, Yamaguchi, Satoshi, Becktor, Jonas P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6723378/
https://www.ncbi.nlm.nih.gov/pubmed/31405207
http://dx.doi.org/10.3390/jcm8081198
_version_ 1783448754107449344
author Stocchero, Michele
Jinno, Yohei
Toia, Marco
Ahmad, Marianne
Papia, Evaggelia
Yamaguchi, Satoshi
Becktor, Jonas P.
author_facet Stocchero, Michele
Jinno, Yohei
Toia, Marco
Ahmad, Marianne
Papia, Evaggelia
Yamaguchi, Satoshi
Becktor, Jonas P.
author_sort Stocchero, Michele
collection PubMed
description Background: The intraosseous temperature during implant installation has never been evaluated in an in vivo controlled setup. The aims were to investigate the influence of a drilling protocol and implant surface on the intraosseous temperature during implant installation, to evaluate the influence of temperature increase on osseointegration and to calculate the heat distribution in cortical bone. Methods: Forty Brånemark implants were installed into the metatarsal bone of Finnish Dorset crossbred sheep according to two different drilling protocols (undersized/non-undersized) and two surfaces (moderately rough/turned). The intraosseous temperature was recorded, and Finite Element Model (FEM) was generated to understand the thermal behavior. Non-decalcified histology was carried out after five weeks of healing. The following osseointegration parameters were calculated: Bone-to-implant contact (BIC), Bone Area Fraction Occupancy (BAFO), and Bone Area Fraction Occupancy up to 1.5 mm (BA1.5). A multiple regression model was used to identify the influencing variables on the histomorphometric parameters. Results: The temperature was affected by the drilling protocol, while no influence was demonstrated by the implant surface. BIC was positively influenced by the undersized drilling protocol and rough surface, BAFO was negatively influenced by the temperature rise, and BA1.5 was negatively influenced by the undersized drilling protocol. FEM showed that the temperature at the implant interface might exceed the limit for bone necrosis. Conclusion: The intraosseous temperature is greatly increased by an undersized drilling protocol but not from the implant surface. The temperature increase negatively affects the bone healing in the proximity of the implant. The undersized drilling protocol for Brånemark implant systems increases the amount of bone at the interface, but it negatively impacts the bone far from the implant.
format Online
Article
Text
id pubmed-6723378
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-67233782019-09-10 Intraosseous Temperature Change during Installation of Dental Implants with Two Different Surfaces and Different Drilling Protocols: An In Vivo Study in Sheep Stocchero, Michele Jinno, Yohei Toia, Marco Ahmad, Marianne Papia, Evaggelia Yamaguchi, Satoshi Becktor, Jonas P. J Clin Med Article Background: The intraosseous temperature during implant installation has never been evaluated in an in vivo controlled setup. The aims were to investigate the influence of a drilling protocol and implant surface on the intraosseous temperature during implant installation, to evaluate the influence of temperature increase on osseointegration and to calculate the heat distribution in cortical bone. Methods: Forty Brånemark implants were installed into the metatarsal bone of Finnish Dorset crossbred sheep according to two different drilling protocols (undersized/non-undersized) and two surfaces (moderately rough/turned). The intraosseous temperature was recorded, and Finite Element Model (FEM) was generated to understand the thermal behavior. Non-decalcified histology was carried out after five weeks of healing. The following osseointegration parameters were calculated: Bone-to-implant contact (BIC), Bone Area Fraction Occupancy (BAFO), and Bone Area Fraction Occupancy up to 1.5 mm (BA1.5). A multiple regression model was used to identify the influencing variables on the histomorphometric parameters. Results: The temperature was affected by the drilling protocol, while no influence was demonstrated by the implant surface. BIC was positively influenced by the undersized drilling protocol and rough surface, BAFO was negatively influenced by the temperature rise, and BA1.5 was negatively influenced by the undersized drilling protocol. FEM showed that the temperature at the implant interface might exceed the limit for bone necrosis. Conclusion: The intraosseous temperature is greatly increased by an undersized drilling protocol but not from the implant surface. The temperature increase negatively affects the bone healing in the proximity of the implant. The undersized drilling protocol for Brånemark implant systems increases the amount of bone at the interface, but it negatively impacts the bone far from the implant. MDPI 2019-08-11 /pmc/articles/PMC6723378/ /pubmed/31405207 http://dx.doi.org/10.3390/jcm8081198 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Stocchero, Michele
Jinno, Yohei
Toia, Marco
Ahmad, Marianne
Papia, Evaggelia
Yamaguchi, Satoshi
Becktor, Jonas P.
Intraosseous Temperature Change during Installation of Dental Implants with Two Different Surfaces and Different Drilling Protocols: An In Vivo Study in Sheep
title Intraosseous Temperature Change during Installation of Dental Implants with Two Different Surfaces and Different Drilling Protocols: An In Vivo Study in Sheep
title_full Intraosseous Temperature Change during Installation of Dental Implants with Two Different Surfaces and Different Drilling Protocols: An In Vivo Study in Sheep
title_fullStr Intraosseous Temperature Change during Installation of Dental Implants with Two Different Surfaces and Different Drilling Protocols: An In Vivo Study in Sheep
title_full_unstemmed Intraosseous Temperature Change during Installation of Dental Implants with Two Different Surfaces and Different Drilling Protocols: An In Vivo Study in Sheep
title_short Intraosseous Temperature Change during Installation of Dental Implants with Two Different Surfaces and Different Drilling Protocols: An In Vivo Study in Sheep
title_sort intraosseous temperature change during installation of dental implants with two different surfaces and different drilling protocols: an in vivo study in sheep
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6723378/
https://www.ncbi.nlm.nih.gov/pubmed/31405207
http://dx.doi.org/10.3390/jcm8081198
work_keys_str_mv AT stoccheromichele intraosseoustemperaturechangeduringinstallationofdentalimplantswithtwodifferentsurfacesanddifferentdrillingprotocolsaninvivostudyinsheep
AT jinnoyohei intraosseoustemperaturechangeduringinstallationofdentalimplantswithtwodifferentsurfacesanddifferentdrillingprotocolsaninvivostudyinsheep
AT toiamarco intraosseoustemperaturechangeduringinstallationofdentalimplantswithtwodifferentsurfacesanddifferentdrillingprotocolsaninvivostudyinsheep
AT ahmadmarianne intraosseoustemperaturechangeduringinstallationofdentalimplantswithtwodifferentsurfacesanddifferentdrillingprotocolsaninvivostudyinsheep
AT papiaevaggelia intraosseoustemperaturechangeduringinstallationofdentalimplantswithtwodifferentsurfacesanddifferentdrillingprotocolsaninvivostudyinsheep
AT yamaguchisatoshi intraosseoustemperaturechangeduringinstallationofdentalimplantswithtwodifferentsurfacesanddifferentdrillingprotocolsaninvivostudyinsheep
AT becktorjonasp intraosseoustemperaturechangeduringinstallationofdentalimplantswithtwodifferentsurfacesanddifferentdrillingprotocolsaninvivostudyinsheep