Non-Equilibrium Potential Responses towards Neutral Orcinol Using All-Solid-State Potentiometric Sensors Integrated with Molecularly Imprinted Polymers

Molecularly imprinted polymer (MIP) receptors have been synthesized, characterized, and applied as new selective receptors in solid-contact ion selective electrodes (ISEs) towards non-dissociated 3,5-dihydroxytoluene (orcinol). Two monomers, namely methacrylic acid (MAA) and acrylamide (AA), were us...

Descripción completa

Detalles Bibliográficos
Autores principales: S. M. Hassan, Saad, E. Amr, Abd El-Galil, H. A. Elbehery, Nada, A. Al-Omar, Mohamed, H. Kamel, Ayman
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6723434/
https://www.ncbi.nlm.nih.gov/pubmed/31349581
http://dx.doi.org/10.3390/polym11081232
_version_ 1783448767015419904
author S. M. Hassan, Saad
E. Amr, Abd El-Galil
H. A. Elbehery, Nada
A. Al-Omar, Mohamed
H. Kamel, Ayman
author_facet S. M. Hassan, Saad
E. Amr, Abd El-Galil
H. A. Elbehery, Nada
A. Al-Omar, Mohamed
H. Kamel, Ayman
author_sort S. M. Hassan, Saad
collection PubMed
description Molecularly imprinted polymer (MIP) receptors have been synthesized, characterized, and applied as new selective receptors in solid-contact ion selective electrodes (ISEs) towards non-dissociated 3,5-dihydroxytoluene (orcinol). Two monomers, namely methacrylic acid (MAA) and acrylamide (AA), were used in the preparation of MIP receptors. Graphene (Gr) was used as the solid contact material between the sensing membrane and the electrical contact substrate. Based on non-equilibrium sensing mechanism, the proposed sensors reveal observably enhanced detection sensitivity towards orcinol with detection limits 1.7 × 10(−5) and 3.3 × 10(−6) M for sensors based on MIP/MAA and MIP/AA, respectively. The selectivity coefficients measured by the modified separate solution method (MSSM) for the proposed sensors showed good selectivity towards orcinol over most common other phenols and inorganic anions. All measurements were made in the presence of 30 mM phosphate buffer solution (PBS) with a pH of 7.0. Potential stability for the proposed sensors was tested by constant-current chronopotentiometry. No water films were formed between the sensing membrane and the electron conductor substrate. The applicability of MIP/MAA incorporated ISE has been checked by recovery test of orcinol in the presence of soil matrix and by standard addition method.
format Online
Article
Text
id pubmed-6723434
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-67234342019-09-10 Non-Equilibrium Potential Responses towards Neutral Orcinol Using All-Solid-State Potentiometric Sensors Integrated with Molecularly Imprinted Polymers S. M. Hassan, Saad E. Amr, Abd El-Galil H. A. Elbehery, Nada A. Al-Omar, Mohamed H. Kamel, Ayman Polymers (Basel) Article Molecularly imprinted polymer (MIP) receptors have been synthesized, characterized, and applied as new selective receptors in solid-contact ion selective electrodes (ISEs) towards non-dissociated 3,5-dihydroxytoluene (orcinol). Two monomers, namely methacrylic acid (MAA) and acrylamide (AA), were used in the preparation of MIP receptors. Graphene (Gr) was used as the solid contact material between the sensing membrane and the electrical contact substrate. Based on non-equilibrium sensing mechanism, the proposed sensors reveal observably enhanced detection sensitivity towards orcinol with detection limits 1.7 × 10(−5) and 3.3 × 10(−6) M for sensors based on MIP/MAA and MIP/AA, respectively. The selectivity coefficients measured by the modified separate solution method (MSSM) for the proposed sensors showed good selectivity towards orcinol over most common other phenols and inorganic anions. All measurements were made in the presence of 30 mM phosphate buffer solution (PBS) with a pH of 7.0. Potential stability for the proposed sensors was tested by constant-current chronopotentiometry. No water films were formed between the sensing membrane and the electron conductor substrate. The applicability of MIP/MAA incorporated ISE has been checked by recovery test of orcinol in the presence of soil matrix and by standard addition method. MDPI 2019-07-25 /pmc/articles/PMC6723434/ /pubmed/31349581 http://dx.doi.org/10.3390/polym11081232 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
S. M. Hassan, Saad
E. Amr, Abd El-Galil
H. A. Elbehery, Nada
A. Al-Omar, Mohamed
H. Kamel, Ayman
Non-Equilibrium Potential Responses towards Neutral Orcinol Using All-Solid-State Potentiometric Sensors Integrated with Molecularly Imprinted Polymers
title Non-Equilibrium Potential Responses towards Neutral Orcinol Using All-Solid-State Potentiometric Sensors Integrated with Molecularly Imprinted Polymers
title_full Non-Equilibrium Potential Responses towards Neutral Orcinol Using All-Solid-State Potentiometric Sensors Integrated with Molecularly Imprinted Polymers
title_fullStr Non-Equilibrium Potential Responses towards Neutral Orcinol Using All-Solid-State Potentiometric Sensors Integrated with Molecularly Imprinted Polymers
title_full_unstemmed Non-Equilibrium Potential Responses towards Neutral Orcinol Using All-Solid-State Potentiometric Sensors Integrated with Molecularly Imprinted Polymers
title_short Non-Equilibrium Potential Responses towards Neutral Orcinol Using All-Solid-State Potentiometric Sensors Integrated with Molecularly Imprinted Polymers
title_sort non-equilibrium potential responses towards neutral orcinol using all-solid-state potentiometric sensors integrated with molecularly imprinted polymers
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6723434/
https://www.ncbi.nlm.nih.gov/pubmed/31349581
http://dx.doi.org/10.3390/polym11081232
work_keys_str_mv AT smhassansaad nonequilibriumpotentialresponsestowardsneutralorcinolusingallsolidstatepotentiometricsensorsintegratedwithmolecularlyimprintedpolymers
AT eamrabdelgalil nonequilibriumpotentialresponsestowardsneutralorcinolusingallsolidstatepotentiometricsensorsintegratedwithmolecularlyimprintedpolymers
AT haelbeherynada nonequilibriumpotentialresponsestowardsneutralorcinolusingallsolidstatepotentiometricsensorsintegratedwithmolecularlyimprintedpolymers
AT aalomarmohamed nonequilibriumpotentialresponsestowardsneutralorcinolusingallsolidstatepotentiometricsensorsintegratedwithmolecularlyimprintedpolymers
AT hkamelayman nonequilibriumpotentialresponsestowardsneutralorcinolusingallsolidstatepotentiometricsensorsintegratedwithmolecularlyimprintedpolymers