Cargando…

Liquid Refractive Index Measurement System Based on Electrowetting Lens

In this paper, a liquid refractive index (LRI) measurement system based on an electrowetting lens was proposed. The system is composed of a light source, a collimating lens, a liquid measurement chamber (LMC), an electrowetting lens and an image sensor, which is integrated into a cylindrical cavity....

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Shi-Long, Nie, Zhong-Quan, Tian, Yan-Ting, Liu, Chao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6723905/
https://www.ncbi.nlm.nih.gov/pubmed/31374816
http://dx.doi.org/10.3390/mi10080515
_version_ 1783448879318958080
author Li, Shi-Long
Nie, Zhong-Quan
Tian, Yan-Ting
Liu, Chao
author_facet Li, Shi-Long
Nie, Zhong-Quan
Tian, Yan-Ting
Liu, Chao
author_sort Li, Shi-Long
collection PubMed
description In this paper, a liquid refractive index (LRI) measurement system based on an electrowetting lens was proposed. The system is composed of a light source, a collimating lens, a liquid measurement chamber (LMC), an electrowetting lens and an image sensor, which is integrated into a cylindrical cavity. The refractive index of the LMC changes with the addition of the measured liquid, and the incident light cannot be focused on the image plane. By adjusting the driving voltage of the electrowetting lens, the curvature of the liquid-liquid interface changes to focus the incident light onto the image plane. The refractive index of the liquid could be measured according to the voltage value. The proposed LRI measurement system has no mechanical moving parts, and the imaging surface remains stationary, which can make the measurement simply and correctly. The experiments show that the refractive index measurement range of the system can be turned from ~1.3300 to ~1.4040, and the measurement accuracy is 10(−4). The system can be used to measure the optical properties of liquids and has broad potential applications in chemical reagent detection and pharmaceutical testing.
format Online
Article
Text
id pubmed-6723905
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-67239052019-09-10 Liquid Refractive Index Measurement System Based on Electrowetting Lens Li, Shi-Long Nie, Zhong-Quan Tian, Yan-Ting Liu, Chao Micromachines (Basel) Article In this paper, a liquid refractive index (LRI) measurement system based on an electrowetting lens was proposed. The system is composed of a light source, a collimating lens, a liquid measurement chamber (LMC), an electrowetting lens and an image sensor, which is integrated into a cylindrical cavity. The refractive index of the LMC changes with the addition of the measured liquid, and the incident light cannot be focused on the image plane. By adjusting the driving voltage of the electrowetting lens, the curvature of the liquid-liquid interface changes to focus the incident light onto the image plane. The refractive index of the liquid could be measured according to the voltage value. The proposed LRI measurement system has no mechanical moving parts, and the imaging surface remains stationary, which can make the measurement simply and correctly. The experiments show that the refractive index measurement range of the system can be turned from ~1.3300 to ~1.4040, and the measurement accuracy is 10(−4). The system can be used to measure the optical properties of liquids and has broad potential applications in chemical reagent detection and pharmaceutical testing. MDPI 2019-08-01 /pmc/articles/PMC6723905/ /pubmed/31374816 http://dx.doi.org/10.3390/mi10080515 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Li, Shi-Long
Nie, Zhong-Quan
Tian, Yan-Ting
Liu, Chao
Liquid Refractive Index Measurement System Based on Electrowetting Lens
title Liquid Refractive Index Measurement System Based on Electrowetting Lens
title_full Liquid Refractive Index Measurement System Based on Electrowetting Lens
title_fullStr Liquid Refractive Index Measurement System Based on Electrowetting Lens
title_full_unstemmed Liquid Refractive Index Measurement System Based on Electrowetting Lens
title_short Liquid Refractive Index Measurement System Based on Electrowetting Lens
title_sort liquid refractive index measurement system based on electrowetting lens
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6723905/
https://www.ncbi.nlm.nih.gov/pubmed/31374816
http://dx.doi.org/10.3390/mi10080515
work_keys_str_mv AT lishilong liquidrefractiveindexmeasurementsystembasedonelectrowettinglens
AT niezhongquan liquidrefractiveindexmeasurementsystembasedonelectrowettinglens
AT tianyanting liquidrefractiveindexmeasurementsystembasedonelectrowettinglens
AT liuchao liquidrefractiveindexmeasurementsystembasedonelectrowettinglens