Serum albumin-fatty acid saturation test
Circulating non-esterified fatty acids (NEFA) are toxic to mammalian cells. They increase in diseases such as diabetes and sepsis. Herein we propose a serum albumin-fatty acid saturation test. • We based our test on three methodologies: isoelectric focusing (IF) of human plasma albumin, staining pro...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6726920/ https://www.ncbi.nlm.nih.gov/pubmed/31508324 http://dx.doi.org/10.1016/j.mex.2019.08.004 |
_version_ | 1783449175767121920 |
---|---|
author | Gonçalves-de-Albuquerque, Cassiano Felippe Barnese, Marcos Roberto Colombo Soares, Mariana Alves Castro Faria, Mauro Velho Silva, Adriana Ribeiro Castro Faria Neto, Hugo Caire Burth, Patrícia Younes-Ibrahim, Mauricio |
author_facet | Gonçalves-de-Albuquerque, Cassiano Felippe Barnese, Marcos Roberto Colombo Soares, Mariana Alves Castro Faria, Mauro Velho Silva, Adriana Ribeiro Castro Faria Neto, Hugo Caire Burth, Patrícia Younes-Ibrahim, Mauricio |
author_sort | Gonçalves-de-Albuquerque, Cassiano Felippe |
collection | PubMed |
description | Circulating non-esterified fatty acids (NEFA) are toxic to mammalian cells. They increase in diseases such as diabetes and sepsis. Herein we propose a serum albumin-fatty acid saturation test. • We based our test on three methodologies: isoelectric focusing (IF) of human plasma albumin, staining proteins after isoelectric focusing in gels with Coomassie Brilliant Blue, and serum albumin measurement with bromocresol green. • The test consists in the determination of albumin IF and staining with bromocresol green. If albumin is saturated with NEFA, it focuses on lower pH, meaning it is the threshold to bind to them. Excessive NEFA is free and toxic. Many other tests are available for NEFA quantification as NEFA kit assay. All colorimetric assays are used for quantification of NEFA and other tests need expensive equipment to read out the results, and they do not measure albumin levels. • Our method focused on albumin-NEFA saturation instead of just NEFA quantification. Critically ill patients have an alteration in both albumin and NEFA. Therefore, our test undergoes less daytime variation compared to assays that measure absolute NEFA values, allowing a more reliable use as an indicator of albumin-fatty acid saturation and NEFA toxicity. |
format | Online Article Text |
id | pubmed-6726920 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-67269202019-09-10 Serum albumin-fatty acid saturation test Gonçalves-de-Albuquerque, Cassiano Felippe Barnese, Marcos Roberto Colombo Soares, Mariana Alves Castro Faria, Mauro Velho Silva, Adriana Ribeiro Castro Faria Neto, Hugo Caire Burth, Patrícia Younes-Ibrahim, Mauricio MethodsX Medicine and Dentistry Circulating non-esterified fatty acids (NEFA) are toxic to mammalian cells. They increase in diseases such as diabetes and sepsis. Herein we propose a serum albumin-fatty acid saturation test. • We based our test on three methodologies: isoelectric focusing (IF) of human plasma albumin, staining proteins after isoelectric focusing in gels with Coomassie Brilliant Blue, and serum albumin measurement with bromocresol green. • The test consists in the determination of albumin IF and staining with bromocresol green. If albumin is saturated with NEFA, it focuses on lower pH, meaning it is the threshold to bind to them. Excessive NEFA is free and toxic. Many other tests are available for NEFA quantification as NEFA kit assay. All colorimetric assays are used for quantification of NEFA and other tests need expensive equipment to read out the results, and they do not measure albumin levels. • Our method focused on albumin-NEFA saturation instead of just NEFA quantification. Critically ill patients have an alteration in both albumin and NEFA. Therefore, our test undergoes less daytime variation compared to assays that measure absolute NEFA values, allowing a more reliable use as an indicator of albumin-fatty acid saturation and NEFA toxicity. Elsevier 2019-08-24 /pmc/articles/PMC6726920/ /pubmed/31508324 http://dx.doi.org/10.1016/j.mex.2019.08.004 Text en © 2019 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Medicine and Dentistry Gonçalves-de-Albuquerque, Cassiano Felippe Barnese, Marcos Roberto Colombo Soares, Mariana Alves Castro Faria, Mauro Velho Silva, Adriana Ribeiro Castro Faria Neto, Hugo Caire Burth, Patrícia Younes-Ibrahim, Mauricio Serum albumin-fatty acid saturation test |
title | Serum albumin-fatty acid saturation test |
title_full | Serum albumin-fatty acid saturation test |
title_fullStr | Serum albumin-fatty acid saturation test |
title_full_unstemmed | Serum albumin-fatty acid saturation test |
title_short | Serum albumin-fatty acid saturation test |
title_sort | serum albumin-fatty acid saturation test |
topic | Medicine and Dentistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6726920/ https://www.ncbi.nlm.nih.gov/pubmed/31508324 http://dx.doi.org/10.1016/j.mex.2019.08.004 |
work_keys_str_mv | AT goncalvesdealbuquerquecassianofelippe serumalbuminfattyacidsaturationtest AT barnesemarcosrobertocolombo serumalbuminfattyacidsaturationtest AT soaresmarianaalves serumalbuminfattyacidsaturationtest AT castrofariamaurovelho serumalbuminfattyacidsaturationtest AT silvaadrianaribeiro serumalbuminfattyacidsaturationtest AT castrofarianetohugocaire serumalbuminfattyacidsaturationtest AT burthpatricia serumalbuminfattyacidsaturationtest AT younesibrahimmauricio serumalbuminfattyacidsaturationtest |