Cargando…

Short-term stent coverage of second-generation zotarolimus-eluting durable polymer stents: Onyx one-month optical coherence tomography study

INTRODUCTION: To date the early strut coverage with the second-generation durable-polymer ONYX zotarolimus-eluting stent (O-ZES) is unknown. AIM: Optical coherence tomography (OCT) assessed the strut coverage of O-ZES at thirty-day follow-up. MATERIAL AND METHODS: OCT was performed after implantatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Roleder, Tomasz, Kedhi, Elvin, Berta, Balazs, Gasior, Pawel, Wanha, Wojciech, Roleder, Magda, Fluder, Joanna, Smolka, Grzegorz, Ochala, Andrzej, Wojakowski, Wojciech
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6727229/
https://www.ncbi.nlm.nih.gov/pubmed/31497046
http://dx.doi.org/10.5114/aic.2019.86009
_version_ 1783449218945384448
author Roleder, Tomasz
Kedhi, Elvin
Berta, Balazs
Gasior, Pawel
Wanha, Wojciech
Roleder, Magda
Fluder, Joanna
Smolka, Grzegorz
Ochala, Andrzej
Wojakowski, Wojciech
author_facet Roleder, Tomasz
Kedhi, Elvin
Berta, Balazs
Gasior, Pawel
Wanha, Wojciech
Roleder, Magda
Fluder, Joanna
Smolka, Grzegorz
Ochala, Andrzej
Wojakowski, Wojciech
author_sort Roleder, Tomasz
collection PubMed
description INTRODUCTION: To date the early strut coverage with the second-generation durable-polymer ONYX zotarolimus-eluting stent (O-ZES) is unknown. AIM: Optical coherence tomography (OCT) assessed the strut coverage of O-ZES at thirty-day follow-up. MATERIAL AND METHODS: OCT was performed after implantation and at 1-month follow-up in 15 patients treated with O-ZES. RESULTS: Mean patient age was 67 ±7 years (73% males). The clinical presentation consisted of acute coronary syndromes (n = 13) and stable coronary disease (n = 2). Four (26%) patients had diabetes. OCT analysis was performed at baseline and 1-month follow-up in all stents. 378 cross-sections with 3582 struts were assessed at baseline and 3661 at follow-up. At follow-up, 88% struts were covered by tissue with a median thickness 37.91 μm (IQR: 22.32–64.15). Median in-stent area obstruction by neointima was 2.64% (IQR: 1.70–4.84). From the total stent covered area, 92.3% showed complete strut coverage. Homogeneous tissue was observed in 74% of cases. There were no differences in minimal lumen area (5.07 ±1.08 mm(2) vs. 4.81 ±0.94 mm(2), p = 0.125) or minimal stent area (4.95 ±1.22 mm(2) vs. 4.92 ±0.99 mm(2)) at baseline and at follow-up. There were no differences in the rate of strut malapposition (4.3% vs. 5.7%, p = 0.417). For all stents, malapposition volume was 47.9 mm(3) at baseline and 51.7 mm(3) at follow-up, giving the late acquired stent malapposition volume of 3.8 mm(3). CONCLUSIONS: The second-generation durable polymer O-ZES showed favorable vessel healing at 30-day OCT follow-up.
format Online
Article
Text
id pubmed-6727229
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-67272292019-09-06 Short-term stent coverage of second-generation zotarolimus-eluting durable polymer stents: Onyx one-month optical coherence tomography study Roleder, Tomasz Kedhi, Elvin Berta, Balazs Gasior, Pawel Wanha, Wojciech Roleder, Magda Fluder, Joanna Smolka, Grzegorz Ochala, Andrzej Wojakowski, Wojciech Postepy Kardiol Interwencyjnej Original Paper INTRODUCTION: To date the early strut coverage with the second-generation durable-polymer ONYX zotarolimus-eluting stent (O-ZES) is unknown. AIM: Optical coherence tomography (OCT) assessed the strut coverage of O-ZES at thirty-day follow-up. MATERIAL AND METHODS: OCT was performed after implantation and at 1-month follow-up in 15 patients treated with O-ZES. RESULTS: Mean patient age was 67 ±7 years (73% males). The clinical presentation consisted of acute coronary syndromes (n = 13) and stable coronary disease (n = 2). Four (26%) patients had diabetes. OCT analysis was performed at baseline and 1-month follow-up in all stents. 378 cross-sections with 3582 struts were assessed at baseline and 3661 at follow-up. At follow-up, 88% struts were covered by tissue with a median thickness 37.91 μm (IQR: 22.32–64.15). Median in-stent area obstruction by neointima was 2.64% (IQR: 1.70–4.84). From the total stent covered area, 92.3% showed complete strut coverage. Homogeneous tissue was observed in 74% of cases. There were no differences in minimal lumen area (5.07 ±1.08 mm(2) vs. 4.81 ±0.94 mm(2), p = 0.125) or minimal stent area (4.95 ±1.22 mm(2) vs. 4.92 ±0.99 mm(2)) at baseline and at follow-up. There were no differences in the rate of strut malapposition (4.3% vs. 5.7%, p = 0.417). For all stents, malapposition volume was 47.9 mm(3) at baseline and 51.7 mm(3) at follow-up, giving the late acquired stent malapposition volume of 3.8 mm(3). CONCLUSIONS: The second-generation durable polymer O-ZES showed favorable vessel healing at 30-day OCT follow-up. Termedia Publishing House 2019-06-26 2019 /pmc/articles/PMC6727229/ /pubmed/31497046 http://dx.doi.org/10.5114/aic.2019.86009 Text en Copyright: © 2019 Termedia Sp. z o. o. http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
spellingShingle Original Paper
Roleder, Tomasz
Kedhi, Elvin
Berta, Balazs
Gasior, Pawel
Wanha, Wojciech
Roleder, Magda
Fluder, Joanna
Smolka, Grzegorz
Ochala, Andrzej
Wojakowski, Wojciech
Short-term stent coverage of second-generation zotarolimus-eluting durable polymer stents: Onyx one-month optical coherence tomography study
title Short-term stent coverage of second-generation zotarolimus-eluting durable polymer stents: Onyx one-month optical coherence tomography study
title_full Short-term stent coverage of second-generation zotarolimus-eluting durable polymer stents: Onyx one-month optical coherence tomography study
title_fullStr Short-term stent coverage of second-generation zotarolimus-eluting durable polymer stents: Onyx one-month optical coherence tomography study
title_full_unstemmed Short-term stent coverage of second-generation zotarolimus-eluting durable polymer stents: Onyx one-month optical coherence tomography study
title_short Short-term stent coverage of second-generation zotarolimus-eluting durable polymer stents: Onyx one-month optical coherence tomography study
title_sort short-term stent coverage of second-generation zotarolimus-eluting durable polymer stents: onyx one-month optical coherence tomography study
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6727229/
https://www.ncbi.nlm.nih.gov/pubmed/31497046
http://dx.doi.org/10.5114/aic.2019.86009
work_keys_str_mv AT roledertomasz shorttermstentcoverageofsecondgenerationzotarolimuselutingdurablepolymerstentsonyxonemonthopticalcoherencetomographystudy
AT kedhielvin shorttermstentcoverageofsecondgenerationzotarolimuselutingdurablepolymerstentsonyxonemonthopticalcoherencetomographystudy
AT bertabalazs shorttermstentcoverageofsecondgenerationzotarolimuselutingdurablepolymerstentsonyxonemonthopticalcoherencetomographystudy
AT gasiorpawel shorttermstentcoverageofsecondgenerationzotarolimuselutingdurablepolymerstentsonyxonemonthopticalcoherencetomographystudy
AT wanhawojciech shorttermstentcoverageofsecondgenerationzotarolimuselutingdurablepolymerstentsonyxonemonthopticalcoherencetomographystudy
AT roledermagda shorttermstentcoverageofsecondgenerationzotarolimuselutingdurablepolymerstentsonyxonemonthopticalcoherencetomographystudy
AT fluderjoanna shorttermstentcoverageofsecondgenerationzotarolimuselutingdurablepolymerstentsonyxonemonthopticalcoherencetomographystudy
AT smolkagrzegorz shorttermstentcoverageofsecondgenerationzotarolimuselutingdurablepolymerstentsonyxonemonthopticalcoherencetomographystudy
AT ochalaandrzej shorttermstentcoverageofsecondgenerationzotarolimuselutingdurablepolymerstentsonyxonemonthopticalcoherencetomographystudy
AT wojakowskiwojciech shorttermstentcoverageofsecondgenerationzotarolimuselutingdurablepolymerstentsonyxonemonthopticalcoherencetomographystudy