BACKGROUND: Aim of this study is to investigate the cyclic fatigue resistance of the Gold treated WaveOne Gold and the Firewire treated EdgeOne Fire instruments. The null hypotesis was that there were no differences between the lifespan of Gold treated and FireWire treated instruments when subjected...

Descripción completa

Detalles Bibliográficos
Autores principales: Gambarini, Gianluca, Galli, Massimo, Di Nardo, Dario, Seracchiani, Marco, Donfrancesco, Orlando, Testarelli, Luca
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6731004/
https://www.ncbi.nlm.nih.gov/pubmed/31516658
http://dx.doi.org/10.4317/jced.55839
_version_ 1783449617850957824
author Gambarini, Gianluca
Galli, Massimo
Di Nardo, Dario
Seracchiani, Marco
Donfrancesco, Orlando
Testarelli, Luca
author_facet Gambarini, Gianluca
Galli, Massimo
Di Nardo, Dario
Seracchiani, Marco
Donfrancesco, Orlando
Testarelli, Luca
author_sort Gambarini, Gianluca
collection PubMed
description BACKGROUND: Aim of this study is to investigate the cyclic fatigue resistance of the Gold treated WaveOne Gold and the Firewire treated EdgeOne Fire instruments. The null hypotesis was that there were no differences between the lifespan of Gold treated and FireWire treated instruments when subjected to cyclic fatigue tests. MATERIAL AND METHODS: 40 new NiTi instruments with a length of 25 mm were tested: 20 Wave One Gold Medium (WOG), tip size 35 and variable taper (Dentsply Maillefer, Ballaigues, Switzerland) and 20 Edge One Fire (EOF) (EdgeEndo, Albuquerque, New Mexico) tip size 35 and the same variable taper. A mobile support for the electric handpiece and a stainless-steel block containing the artificial canals were used. The same artificial root canal with a 90 degrees angle of curvature and 2 mm radius of curvature was used for all the tested instruments and the WOG counter-clock wise reciprocating motion with an engaging angle of 150° and a disengaging angle of 30° at 300 rpm, was selected for the test. All instruments were inserted at the same length (18mm) and then rotated in the same reciprocating motion until fracture occurred: the time was stopped as soon as the fracture was visible and video-recorded with a 1/100 sec chronometer. Differences among groups were statistically evaluated with an analysis of variance test ANOVA (significance level was set at p<0.05). RESULTS: Mean values of time to fracture (TtF) for EOF instruments were 28,00 seconds (SD +/- 2,64) and for WOG instruments were 14,67 seconds (SD +/- 2,41). Statistical analysis found significant differences between the TtF of the two instruments (p<0,05). CONCLUSIONS: Firewire instruments resulted to be about two times more resistant to cyclic fatigue when compared with identical instruments made with Gold treatment. Key words:Endodontics, NiTi, Waveone Gold, EdgeOne Fire, Cyclic Fatigue.
format Online
Article
Text
id pubmed-6731004
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Medicina Oral S.L.
record_format MEDLINE/PubMed
spelling pubmed-67310042019-09-12 Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments: WaveOne Gold vs EdgeOne Fire Gambarini, Gianluca Galli, Massimo Di Nardo, Dario Seracchiani, Marco Donfrancesco, Orlando Testarelli, Luca J Clin Exp Dent Research BACKGROUND: Aim of this study is to investigate the cyclic fatigue resistance of the Gold treated WaveOne Gold and the Firewire treated EdgeOne Fire instruments. The null hypotesis was that there were no differences between the lifespan of Gold treated and FireWire treated instruments when subjected to cyclic fatigue tests. MATERIAL AND METHODS: 40 new NiTi instruments with a length of 25 mm were tested: 20 Wave One Gold Medium (WOG), tip size 35 and variable taper (Dentsply Maillefer, Ballaigues, Switzerland) and 20 Edge One Fire (EOF) (EdgeEndo, Albuquerque, New Mexico) tip size 35 and the same variable taper. A mobile support for the electric handpiece and a stainless-steel block containing the artificial canals were used. The same artificial root canal with a 90 degrees angle of curvature and 2 mm radius of curvature was used for all the tested instruments and the WOG counter-clock wise reciprocating motion with an engaging angle of 150° and a disengaging angle of 30° at 300 rpm, was selected for the test. All instruments were inserted at the same length (18mm) and then rotated in the same reciprocating motion until fracture occurred: the time was stopped as soon as the fracture was visible and video-recorded with a 1/100 sec chronometer. Differences among groups were statistically evaluated with an analysis of variance test ANOVA (significance level was set at p<0.05). RESULTS: Mean values of time to fracture (TtF) for EOF instruments were 28,00 seconds (SD +/- 2,64) and for WOG instruments were 14,67 seconds (SD +/- 2,41). Statistical analysis found significant differences between the TtF of the two instruments (p<0,05). CONCLUSIONS: Firewire instruments resulted to be about two times more resistant to cyclic fatigue when compared with identical instruments made with Gold treatment. Key words:Endodontics, NiTi, Waveone Gold, EdgeOne Fire, Cyclic Fatigue. Medicina Oral S.L. 2019-07-01 /pmc/articles/PMC6731004/ /pubmed/31516658 http://dx.doi.org/10.4317/jced.55839 Text en Copyright: © 2019 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Gambarini, Gianluca
Galli, Massimo
Di Nardo, Dario
Seracchiani, Marco
Donfrancesco, Orlando
Testarelli, Luca
Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments: WaveOne Gold vs EdgeOne Fire
title Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments: WaveOne Gold vs EdgeOne Fire
title_full Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments: WaveOne Gold vs EdgeOne Fire
title_fullStr Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments: WaveOne Gold vs EdgeOne Fire
title_full_unstemmed Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments: WaveOne Gold vs EdgeOne Fire
title_short Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments: WaveOne Gold vs EdgeOne Fire
title_sort differences in cyclic fatigue lifespan between two different heat treated niti endodontic rotary instruments: waveone gold vs edgeone fire
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6731004/
https://www.ncbi.nlm.nih.gov/pubmed/31516658
http://dx.doi.org/10.4317/jced.55839
work_keys_str_mv AT gambarinigianluca differencesincyclicfatiguelifespanbetweentwodifferentheattreatednitiendodonticrotaryinstrumentswaveonegoldvsedgeonefire
AT gallimassimo differencesincyclicfatiguelifespanbetweentwodifferentheattreatednitiendodonticrotaryinstrumentswaveonegoldvsedgeonefire
AT dinardodario differencesincyclicfatiguelifespanbetweentwodifferentheattreatednitiendodonticrotaryinstrumentswaveonegoldvsedgeonefire
AT seracchianimarco differencesincyclicfatiguelifespanbetweentwodifferentheattreatednitiendodonticrotaryinstrumentswaveonegoldvsedgeonefire
AT donfrancescoorlando differencesincyclicfatiguelifespanbetweentwodifferentheattreatednitiendodonticrotaryinstrumentswaveonegoldvsedgeonefire
AT testarelliluca differencesincyclicfatiguelifespanbetweentwodifferentheattreatednitiendodonticrotaryinstrumentswaveonegoldvsedgeonefire