Cargando…
Endoscopic Optical Coherence Tomography for Assessing Inhalation Airway Injury: A Technical Review
Diagnosis of inhalation injury has been clinically challenging. Currently, assessment of inhalation injury relies on subjective clinical exams and bronchoscopy, which provides little understanding of tissue conditions and results in limited prognostics. Endoscopic Optical coherence tomography (OCT)...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6731096/ https://www.ncbi.nlm.nih.gov/pubmed/31497378 http://dx.doi.org/10.4172/2161-119X.1000366 |
_version_ | 1783449631618760704 |
---|---|
author | Miao, Yusi Brenner, Matthew Chen, Zhongping |
author_facet | Miao, Yusi Brenner, Matthew Chen, Zhongping |
author_sort | Miao, Yusi |
collection | PubMed |
description | Diagnosis of inhalation injury has been clinically challenging. Currently, assessment of inhalation injury relies on subjective clinical exams and bronchoscopy, which provides little understanding of tissue conditions and results in limited prognostics. Endoscopic Optical coherence tomography (OCT) technology has been recently utilized in the airway for direct assessment of respiratory tract disorders and injuries. Endoscopic OCT is capable of capturing high-resolution images of tissue morphology 1-3 mm beneath the surface as well as the complex 3D anatomical shape. Previous studies indicate that changes in airway histopathology can be found in the OCT image almost immediately after inhalation of smoke and other toxic chemicals, which correlates well with histology and pulmonary function tests. This review summarizes the recent development of endoscopic OCT technology for airway imaging, current uses of OCT for inhalation injury, and possible future directions. |
format | Online Article Text |
id | pubmed-6731096 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
record_format | MEDLINE/PubMed |
spelling | pubmed-67310962020-04-04 Endoscopic Optical Coherence Tomography for Assessing Inhalation Airway Injury: A Technical Review Miao, Yusi Brenner, Matthew Chen, Zhongping Otolaryngol (Sunnyvale) Article Diagnosis of inhalation injury has been clinically challenging. Currently, assessment of inhalation injury relies on subjective clinical exams and bronchoscopy, which provides little understanding of tissue conditions and results in limited prognostics. Endoscopic Optical coherence tomography (OCT) technology has been recently utilized in the airway for direct assessment of respiratory tract disorders and injuries. Endoscopic OCT is capable of capturing high-resolution images of tissue morphology 1-3 mm beneath the surface as well as the complex 3D anatomical shape. Previous studies indicate that changes in airway histopathology can be found in the OCT image almost immediately after inhalation of smoke and other toxic chemicals, which correlates well with histology and pulmonary function tests. This review summarizes the recent development of endoscopic OCT technology for airway imaging, current uses of OCT for inhalation injury, and possible future directions. 2019-04-04 2019 /pmc/articles/PMC6731096/ /pubmed/31497378 http://dx.doi.org/10.4172/2161-119X.1000366 Text en This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Miao, Yusi Brenner, Matthew Chen, Zhongping Endoscopic Optical Coherence Tomography for Assessing Inhalation Airway Injury: A Technical Review |
title | Endoscopic Optical Coherence Tomography for Assessing Inhalation Airway Injury: A Technical Review |
title_full | Endoscopic Optical Coherence Tomography for Assessing Inhalation Airway Injury: A Technical Review |
title_fullStr | Endoscopic Optical Coherence Tomography for Assessing Inhalation Airway Injury: A Technical Review |
title_full_unstemmed | Endoscopic Optical Coherence Tomography for Assessing Inhalation Airway Injury: A Technical Review |
title_short | Endoscopic Optical Coherence Tomography for Assessing Inhalation Airway Injury: A Technical Review |
title_sort | endoscopic optical coherence tomography for assessing inhalation airway injury: a technical review |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6731096/ https://www.ncbi.nlm.nih.gov/pubmed/31497378 http://dx.doi.org/10.4172/2161-119X.1000366 |
work_keys_str_mv | AT miaoyusi endoscopicopticalcoherencetomographyforassessinginhalationairwayinjuryatechnicalreview AT brennermatthew endoscopicopticalcoherencetomographyforassessinginhalationairwayinjuryatechnicalreview AT chenzhongping endoscopicopticalcoherencetomographyforassessinginhalationairwayinjuryatechnicalreview |