Cargando…

PIV investigation of the flow fields in subject-specific vertebro-basilar (VA-BA) junction

BACKGROUND: As the only arterial structure of which two main arteries merged into one, the vertebro-basilar (VA-BA) system is one of the favorite sites of cerebral atherosclerotic plaques. The aim of this study was to investigate the detailed hemodynamics characteristics in the VA-BA system. METHODS...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Guangyu, Wei, Yuan, Yuan, Qi, Yang, Jian, Yeo, Joon Hock
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6731569/
https://www.ncbi.nlm.nih.gov/pubmed/31492145
http://dx.doi.org/10.1186/s12938-019-0711-9
_version_ 1783449695147786240
author Zhu, Guangyu
Wei, Yuan
Yuan, Qi
Yang, Jian
Yeo, Joon Hock
author_facet Zhu, Guangyu
Wei, Yuan
Yuan, Qi
Yang, Jian
Yeo, Joon Hock
author_sort Zhu, Guangyu
collection PubMed
description BACKGROUND: As the only arterial structure of which two main arteries merged into one, the vertebro-basilar (VA-BA) system is one of the favorite sites of cerebral atherosclerotic plaques. The aim of this study was to investigate the detailed hemodynamics characteristics in the VA-BA system. METHODS: A scale-up subject-specific flow phantom of VA-BA system was fabricated based on the computed tomography angiography (CTA) scanning images of a healthy adult. Flow fields in eight axial planes and six radial planes were measured and analyzed by using particle image velocimetry (PIV) under steady flow conditions of [Formula: see text] , [Formula: see text] . A water–glycerin mixture was used as the working fluid. RESULTS: The flow in the current model exhibited highly three-dimensional characteristics. The confluence of VAs flow formed bimodal velocity distribution near the confluence apex. Due to the asymmetrical structural configuration, the bimodal velocity profile skewed towards left, and sharper peaks were observed under higher Reynolds condition. Secondary flow characterized by two vortices formed in the radial planes where 10 mm downstream the confluence apex and persists along the BA under both Reynolds numbers. The strength of secondary flow under [Formula: see text] is around 8% higher than that under [Formula: see text] , and decayed nonlinearly along the flow direction. In addition, a low momentum recirculation region induced by boundary layer separation was observed near the confluence apex. The wall shear stress (WSS) in the recirculation area was found to be lower than 0.4 Pa. This region coincides well with the preferential site of vascular lesions in the VA-BA system. CONCLUSIONS: This preliminary study verified that the subject-specific in-vitro experiment is capable of reflecting the detailed flow features in the VA-BA system. The findings from this study may help to expand the understanding of the hemodynamics in the VA-BA system, and further clarifying the mechanism that underlying the localization of vascular lesions.
format Online
Article
Text
id pubmed-6731569
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-67315692019-09-12 PIV investigation of the flow fields in subject-specific vertebro-basilar (VA-BA) junction Zhu, Guangyu Wei, Yuan Yuan, Qi Yang, Jian Yeo, Joon Hock Biomed Eng Online Research BACKGROUND: As the only arterial structure of which two main arteries merged into one, the vertebro-basilar (VA-BA) system is one of the favorite sites of cerebral atherosclerotic plaques. The aim of this study was to investigate the detailed hemodynamics characteristics in the VA-BA system. METHODS: A scale-up subject-specific flow phantom of VA-BA system was fabricated based on the computed tomography angiography (CTA) scanning images of a healthy adult. Flow fields in eight axial planes and six radial planes were measured and analyzed by using particle image velocimetry (PIV) under steady flow conditions of [Formula: see text] , [Formula: see text] . A water–glycerin mixture was used as the working fluid. RESULTS: The flow in the current model exhibited highly three-dimensional characteristics. The confluence of VAs flow formed bimodal velocity distribution near the confluence apex. Due to the asymmetrical structural configuration, the bimodal velocity profile skewed towards left, and sharper peaks were observed under higher Reynolds condition. Secondary flow characterized by two vortices formed in the radial planes where 10 mm downstream the confluence apex and persists along the BA under both Reynolds numbers. The strength of secondary flow under [Formula: see text] is around 8% higher than that under [Formula: see text] , and decayed nonlinearly along the flow direction. In addition, a low momentum recirculation region induced by boundary layer separation was observed near the confluence apex. The wall shear stress (WSS) in the recirculation area was found to be lower than 0.4 Pa. This region coincides well with the preferential site of vascular lesions in the VA-BA system. CONCLUSIONS: This preliminary study verified that the subject-specific in-vitro experiment is capable of reflecting the detailed flow features in the VA-BA system. The findings from this study may help to expand the understanding of the hemodynamics in the VA-BA system, and further clarifying the mechanism that underlying the localization of vascular lesions. BioMed Central 2019-09-06 /pmc/articles/PMC6731569/ /pubmed/31492145 http://dx.doi.org/10.1186/s12938-019-0711-9 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Zhu, Guangyu
Wei, Yuan
Yuan, Qi
Yang, Jian
Yeo, Joon Hock
PIV investigation of the flow fields in subject-specific vertebro-basilar (VA-BA) junction
title PIV investigation of the flow fields in subject-specific vertebro-basilar (VA-BA) junction
title_full PIV investigation of the flow fields in subject-specific vertebro-basilar (VA-BA) junction
title_fullStr PIV investigation of the flow fields in subject-specific vertebro-basilar (VA-BA) junction
title_full_unstemmed PIV investigation of the flow fields in subject-specific vertebro-basilar (VA-BA) junction
title_short PIV investigation of the flow fields in subject-specific vertebro-basilar (VA-BA) junction
title_sort piv investigation of the flow fields in subject-specific vertebro-basilar (va-ba) junction
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6731569/
https://www.ncbi.nlm.nih.gov/pubmed/31492145
http://dx.doi.org/10.1186/s12938-019-0711-9
work_keys_str_mv AT zhuguangyu pivinvestigationoftheflowfieldsinsubjectspecificvertebrobasilarvabajunction
AT weiyuan pivinvestigationoftheflowfieldsinsubjectspecificvertebrobasilarvabajunction
AT yuanqi pivinvestigationoftheflowfieldsinsubjectspecificvertebrobasilarvabajunction
AT yangjian pivinvestigationoftheflowfieldsinsubjectspecificvertebrobasilarvabajunction
AT yeojoonhock pivinvestigationoftheflowfieldsinsubjectspecificvertebrobasilarvabajunction