Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical study
BACKGROUND: Clear aligners (CA) are among the most chosen orthodontic therapies for patients who require an invisible treatment. Previous studies showed that the thermoforming process and the complexity of the intraoral environment might alter the properties of these devices. The aim of the current...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6732265/ https://www.ncbi.nlm.nih.gov/pubmed/31495908 http://dx.doi.org/10.1186/s40510-019-0289-6 |
_version_ | 1783449789533257728 |
---|---|
author | Bucci, Rosaria Rongo, Roberto Levatè, Carmine Michelotti, Ambrosina Barone, Sandro Razionale, Armando Viviano D’Antò, Vincenzo |
author_facet | Bucci, Rosaria Rongo, Roberto Levatè, Carmine Michelotti, Ambrosina Barone, Sandro Razionale, Armando Viviano D’Antò, Vincenzo |
author_sort | Bucci, Rosaria |
collection | PubMed |
description | BACKGROUND: Clear aligners (CA) are among the most chosen orthodontic therapies for patients who require an invisible treatment. Previous studies showed that the thermoforming process and the complexity of the intraoral environment might alter the properties of these devices. The aim of the current prospective clinical study was to assess the thickness changes of the CA after 10 days of intraoral use. The secondary aim was to assess the reproducibility of the thermoforming process, in terms of aligner thickness. MATERIALS AND METHODS: CA from 18 consecutive patients (13 women, 5 men, mean age 28.8 ± 9.6 years) were investigated. Before intraoral exposure (T0), the thickness of the unused CA was measured at different occlusal points on a 3D model with a dedicated software (Geomagic Qualify 2013; 3D Systems, Rock Hill, SC, USA). Two CA configurations were studied: passive maxillary aligner (P—no tooth movement; no shape for attachments) and active maxillary aligner (A—tooth movement; shape for attachments and divot). The used aligners were returned after 10 days (T1) and the thickness measurements were repeated. A Student’s t test for paired data (T1 vs. T0) was applied to compare the thicknesses of used and unused devices (significance level after Bonferroni correction for multiple comparison was set at p < 0.0014). Furthermore, to study the reproducibility of the thermoforming process, P and A aligners were thermoformed twice, and the thicknesses of the two unused thermoformed devices were compared by means of Student’s t test for paired data (significance level after Bonferroni correction for multiple comparison was set at p < 0.0014) and Dahlberg’s error. RESULTS: The thermoforming process showed good reproducibility for both aligner configurations, with a maximum Dahlberg’s error of 0.13 mm. After intraoral use, the thickness of P showed some statistically significant, but not clinically relevant, thickness changes as compared to the unused aligners, while A did not show any significant changes. CONCLUSION: Considering the thickness changes, the thermoforming process is reliable both with active and passive aligner configurations. Also, the CA examined show good thickness stability after physiological intraoral ageing in a population of healthy adults. |
format | Online Article Text |
id | pubmed-6732265 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-67322652019-09-22 Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical study Bucci, Rosaria Rongo, Roberto Levatè, Carmine Michelotti, Ambrosina Barone, Sandro Razionale, Armando Viviano D’Antò, Vincenzo Prog Orthod Research BACKGROUND: Clear aligners (CA) are among the most chosen orthodontic therapies for patients who require an invisible treatment. Previous studies showed that the thermoforming process and the complexity of the intraoral environment might alter the properties of these devices. The aim of the current prospective clinical study was to assess the thickness changes of the CA after 10 days of intraoral use. The secondary aim was to assess the reproducibility of the thermoforming process, in terms of aligner thickness. MATERIALS AND METHODS: CA from 18 consecutive patients (13 women, 5 men, mean age 28.8 ± 9.6 years) were investigated. Before intraoral exposure (T0), the thickness of the unused CA was measured at different occlusal points on a 3D model with a dedicated software (Geomagic Qualify 2013; 3D Systems, Rock Hill, SC, USA). Two CA configurations were studied: passive maxillary aligner (P—no tooth movement; no shape for attachments) and active maxillary aligner (A—tooth movement; shape for attachments and divot). The used aligners were returned after 10 days (T1) and the thickness measurements were repeated. A Student’s t test for paired data (T1 vs. T0) was applied to compare the thicknesses of used and unused devices (significance level after Bonferroni correction for multiple comparison was set at p < 0.0014). Furthermore, to study the reproducibility of the thermoforming process, P and A aligners were thermoformed twice, and the thicknesses of the two unused thermoformed devices were compared by means of Student’s t test for paired data (significance level after Bonferroni correction for multiple comparison was set at p < 0.0014) and Dahlberg’s error. RESULTS: The thermoforming process showed good reproducibility for both aligner configurations, with a maximum Dahlberg’s error of 0.13 mm. After intraoral use, the thickness of P showed some statistically significant, but not clinically relevant, thickness changes as compared to the unused aligners, while A did not show any significant changes. CONCLUSION: Considering the thickness changes, the thermoforming process is reliable both with active and passive aligner configurations. Also, the CA examined show good thickness stability after physiological intraoral ageing in a population of healthy adults. Springer Berlin Heidelberg 2019-09-09 /pmc/articles/PMC6732265/ /pubmed/31495908 http://dx.doi.org/10.1186/s40510-019-0289-6 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Research Bucci, Rosaria Rongo, Roberto Levatè, Carmine Michelotti, Ambrosina Barone, Sandro Razionale, Armando Viviano D’Antò, Vincenzo Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical study |
title | Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical study |
title_full | Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical study |
title_fullStr | Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical study |
title_full_unstemmed | Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical study |
title_short | Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical study |
title_sort | thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6732265/ https://www.ncbi.nlm.nih.gov/pubmed/31495908 http://dx.doi.org/10.1186/s40510-019-0289-6 |
work_keys_str_mv | AT buccirosaria thicknessoforthodonticclearalignersafterthermoformingandafter10daysofintraoralexposureaprospectiveclinicalstudy AT rongoroberto thicknessoforthodonticclearalignersafterthermoformingandafter10daysofintraoralexposureaprospectiveclinicalstudy AT levatecarmine thicknessoforthodonticclearalignersafterthermoformingandafter10daysofintraoralexposureaprospectiveclinicalstudy AT michelottiambrosina thicknessoforthodonticclearalignersafterthermoformingandafter10daysofintraoralexposureaprospectiveclinicalstudy AT baronesandro thicknessoforthodonticclearalignersafterthermoformingandafter10daysofintraoralexposureaprospectiveclinicalstudy AT razionalearmandoviviano thicknessoforthodonticclearalignersafterthermoformingandafter10daysofintraoralexposureaprospectiveclinicalstudy AT dantovincenzo thicknessoforthodonticclearalignersafterthermoformingandafter10daysofintraoralexposureaprospectiveclinicalstudy |