Cargando…

Handheld ultrasound to reduce requests for inappropriate echocardiogram (HURRIE)

BACKGROUND: Handheld ultrasound could provide sufficient information to satisfy the clinical questions underlying ‘rarely appropriate’ echo requests, but there are limited data about its use as a gatekeeper to standard echocardiography. We sought to determine whether the use of handheld ultrasound c...

Descripción completa

Detalles Bibliográficos
Autores principales: Haji, Kawa, Wong, Chiew, Neil, Christopher, Cox, Nicholas, Mulligan, Andrew, Wright, Leah, Vogrin, Sara, Marwick, Thomas H
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bioscientifica Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6733360/
https://www.ncbi.nlm.nih.gov/pubmed/31516721
http://dx.doi.org/10.1530/ERP-19-0016
_version_ 1783449969638768640
author Haji, Kawa
Wong, Chiew
Neil, Christopher
Cox, Nicholas
Mulligan, Andrew
Wright, Leah
Vogrin, Sara
Marwick, Thomas H
author_facet Haji, Kawa
Wong, Chiew
Neil, Christopher
Cox, Nicholas
Mulligan, Andrew
Wright, Leah
Vogrin, Sara
Marwick, Thomas H
author_sort Haji, Kawa
collection PubMed
description BACKGROUND: Handheld ultrasound could provide sufficient information to satisfy the clinical questions underlying ‘rarely appropriate’ echo requests, but there are limited data about its use as a gatekeeper to standard echocardiography. We sought to determine whether the use of handheld ultrasound could improve the appropriate use of echocardiography. METHOD: A prospective study comparing handheld ultrasound strategy to standard echocardiography for studies deemed rarely appropriate, using a questionnaire based on appropriate use criteria was conducted across two hospitals, from October 2017 to April 2018. RESULTS: Groups undergoing Handheld ultrasound (n = 76, 58 (46.5–72.5) years, 53 males, 78% outpatients) and standard echocardiography (n = 72, 61 (49.0–71.5) years, 42 males, 76% outpatients) were comparable. There was a significant decrease in the time to scan from just over 1 month in standard group to a median of 12 days in handheld ultrasound group (P < 0.001). This difference was small for inpatients (from 1 day to a median of 10 min in handheld ultrasound, P = 0.014), but prominent in outpatients (from 1.5 months in the standard group to median of 2 weeks in the handheld ultrasound group, P < 0.001). There was no increase in the need for follow-up scan within 6 months and no significant differences in length of hospital stay for inpatients. CONCLUSION: Handheld ultrasound can be an effective gatekeeper to standard echocardiography for requests deemed rarely appropriate, reducing time to echocardiography significantly and potentially decreasing the need for standard echocardiography by up to 20%.
format Online
Article
Text
id pubmed-6733360
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Bioscientifica Ltd
record_format MEDLINE/PubMed
spelling pubmed-67333602019-09-12 Handheld ultrasound to reduce requests for inappropriate echocardiogram (HURRIE) Haji, Kawa Wong, Chiew Neil, Christopher Cox, Nicholas Mulligan, Andrew Wright, Leah Vogrin, Sara Marwick, Thomas H Echo Res Pract Research BACKGROUND: Handheld ultrasound could provide sufficient information to satisfy the clinical questions underlying ‘rarely appropriate’ echo requests, but there are limited data about its use as a gatekeeper to standard echocardiography. We sought to determine whether the use of handheld ultrasound could improve the appropriate use of echocardiography. METHOD: A prospective study comparing handheld ultrasound strategy to standard echocardiography for studies deemed rarely appropriate, using a questionnaire based on appropriate use criteria was conducted across two hospitals, from October 2017 to April 2018. RESULTS: Groups undergoing Handheld ultrasound (n = 76, 58 (46.5–72.5) years, 53 males, 78% outpatients) and standard echocardiography (n = 72, 61 (49.0–71.5) years, 42 males, 76% outpatients) were comparable. There was a significant decrease in the time to scan from just over 1 month in standard group to a median of 12 days in handheld ultrasound group (P < 0.001). This difference was small for inpatients (from 1 day to a median of 10 min in handheld ultrasound, P = 0.014), but prominent in outpatients (from 1.5 months in the standard group to median of 2 weeks in the handheld ultrasound group, P < 0.001). There was no increase in the need for follow-up scan within 6 months and no significant differences in length of hospital stay for inpatients. CONCLUSION: Handheld ultrasound can be an effective gatekeeper to standard echocardiography for requests deemed rarely appropriate, reducing time to echocardiography significantly and potentially decreasing the need for standard echocardiography by up to 20%. Bioscientifica Ltd 2019-08-07 /pmc/articles/PMC6733360/ /pubmed/31516721 http://dx.doi.org/10.1530/ERP-19-0016 Text en © 2019 The authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (http://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Research
Haji, Kawa
Wong, Chiew
Neil, Christopher
Cox, Nicholas
Mulligan, Andrew
Wright, Leah
Vogrin, Sara
Marwick, Thomas H
Handheld ultrasound to reduce requests for inappropriate echocardiogram (HURRIE)
title Handheld ultrasound to reduce requests for inappropriate echocardiogram (HURRIE)
title_full Handheld ultrasound to reduce requests for inappropriate echocardiogram (HURRIE)
title_fullStr Handheld ultrasound to reduce requests for inappropriate echocardiogram (HURRIE)
title_full_unstemmed Handheld ultrasound to reduce requests for inappropriate echocardiogram (HURRIE)
title_short Handheld ultrasound to reduce requests for inappropriate echocardiogram (HURRIE)
title_sort handheld ultrasound to reduce requests for inappropriate echocardiogram (hurrie)
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6733360/
https://www.ncbi.nlm.nih.gov/pubmed/31516721
http://dx.doi.org/10.1530/ERP-19-0016
work_keys_str_mv AT hajikawa handheldultrasoundtoreducerequestsforinappropriateechocardiogramhurrie
AT wongchiew handheldultrasoundtoreducerequestsforinappropriateechocardiogramhurrie
AT neilchristopher handheldultrasoundtoreducerequestsforinappropriateechocardiogramhurrie
AT coxnicholas handheldultrasoundtoreducerequestsforinappropriateechocardiogramhurrie
AT mulliganandrew handheldultrasoundtoreducerequestsforinappropriateechocardiogramhurrie
AT wrightleah handheldultrasoundtoreducerequestsforinappropriateechocardiogramhurrie
AT vogrinsara handheldultrasoundtoreducerequestsforinappropriateechocardiogramhurrie
AT marwickthomash handheldultrasoundtoreducerequestsforinappropriateechocardiogramhurrie