Cargando…

Automatic Respiratory Gating Hepatic DCEUS-based Dual-phase Multi-parametric Functional Perfusion Imaging using a Derivative Principal Component Analysis

Purpose: Angiogenesis in liver cancers can be characterized by hepatic functional perfusion imaging (FPI) on the basis of dynamic contrast-enhanced ultrasound (DCEUS). However, accuracy is limited by breathing motion which results in out-of-plane image artifacts. Current hepatic FPI studies do not c...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Diya, Cloutier, Guy, Fan, Yan, Hou, Yanli, Su, Zhe, Su, Qiang, Wan, Mingxi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Ivyspring International Publisher 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6735512/
https://www.ncbi.nlm.nih.gov/pubmed/31534542
http://dx.doi.org/10.7150/thno.37284
_version_ 1783450364033368064
author Wang, Diya
Cloutier, Guy
Fan, Yan
Hou, Yanli
Su, Zhe
Su, Qiang
Wan, Mingxi
author_facet Wang, Diya
Cloutier, Guy
Fan, Yan
Hou, Yanli
Su, Zhe
Su, Qiang
Wan, Mingxi
author_sort Wang, Diya
collection PubMed
description Purpose: Angiogenesis in liver cancers can be characterized by hepatic functional perfusion imaging (FPI) on the basis of dynamic contrast-enhanced ultrasound (DCEUS). However, accuracy is limited by breathing motion which results in out-of-plane image artifacts. Current hepatic FPI studies do not correct for these artifacts and lack the evaluation of correction accuracy. Thus, a hepatic DCEUS-based dual-phase multi-parametric FPI (DM-FPI) scheme using a derivative principal component analysis (PCA) respiratory gating is proposed to overcome these limitations. Materials and Methods: By considering severe 3D out-of-plane respiratory motions, the proposed scheme's accuracy was verified with in vitro DCEUS experiments in a flow model mimicking a hepatic vein. The feasibility was further demonstrated by considering in vivo DCEUS measurements in normal rabbit livers, and hepatic cavernous hemangioma and hepatocellular carcinoma in patients. After respiratory kinetics was extracted through PCA of DCEUS sequences under free-breathing condition, dual-phase respiratory gating microbubble kinetics was identified by using a derivative PCA zero-crossing dual-phase detection, respectively. Six dual-phase hemodynamic parameters were estimated from the dual-phase microbubble kinetics and DM-FPI was then reconstructed via color-coding to quantify 2.5D angiogenic hemodynamic distribution for live tumors. Results: Compared with no respiratory gating, the mean square error of respiratory gating DM-FPI decreased by 1893.9 ± 965.4 (p < 0.05), and mean noise coefficients decreased by 17.5 ± 7.1 (p < 0.05), whereas correlation coefficients improved by 0.4 ± 0.2 (p < 0.01). DM-FPI observably removed severe respiratory motion artifacts on PFI and markedly enhanced the accuracy and robustness both in vitro and in vivo. Conclusions: DM-FPI precisely characterized and distinguished the heterogeneous angiogenic hemodynamics about perfusion volume, blood flow and flow rate within two anatomical sections in the normal liver, and in benign and malignant hepatic tumors. DCEUS-based DM-FPI scheme might be a useful tool to help clinicians diagnose and provide suitable therapies for liver tumors.
format Online
Article
Text
id pubmed-6735512
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Ivyspring International Publisher
record_format MEDLINE/PubMed
spelling pubmed-67355122019-09-18 Automatic Respiratory Gating Hepatic DCEUS-based Dual-phase Multi-parametric Functional Perfusion Imaging using a Derivative Principal Component Analysis Wang, Diya Cloutier, Guy Fan, Yan Hou, Yanli Su, Zhe Su, Qiang Wan, Mingxi Theranostics Research Paper Purpose: Angiogenesis in liver cancers can be characterized by hepatic functional perfusion imaging (FPI) on the basis of dynamic contrast-enhanced ultrasound (DCEUS). However, accuracy is limited by breathing motion which results in out-of-plane image artifacts. Current hepatic FPI studies do not correct for these artifacts and lack the evaluation of correction accuracy. Thus, a hepatic DCEUS-based dual-phase multi-parametric FPI (DM-FPI) scheme using a derivative principal component analysis (PCA) respiratory gating is proposed to overcome these limitations. Materials and Methods: By considering severe 3D out-of-plane respiratory motions, the proposed scheme's accuracy was verified with in vitro DCEUS experiments in a flow model mimicking a hepatic vein. The feasibility was further demonstrated by considering in vivo DCEUS measurements in normal rabbit livers, and hepatic cavernous hemangioma and hepatocellular carcinoma in patients. After respiratory kinetics was extracted through PCA of DCEUS sequences under free-breathing condition, dual-phase respiratory gating microbubble kinetics was identified by using a derivative PCA zero-crossing dual-phase detection, respectively. Six dual-phase hemodynamic parameters were estimated from the dual-phase microbubble kinetics and DM-FPI was then reconstructed via color-coding to quantify 2.5D angiogenic hemodynamic distribution for live tumors. Results: Compared with no respiratory gating, the mean square error of respiratory gating DM-FPI decreased by 1893.9 ± 965.4 (p < 0.05), and mean noise coefficients decreased by 17.5 ± 7.1 (p < 0.05), whereas correlation coefficients improved by 0.4 ± 0.2 (p < 0.01). DM-FPI observably removed severe respiratory motion artifacts on PFI and markedly enhanced the accuracy and robustness both in vitro and in vivo. Conclusions: DM-FPI precisely characterized and distinguished the heterogeneous angiogenic hemodynamics about perfusion volume, blood flow and flow rate within two anatomical sections in the normal liver, and in benign and malignant hepatic tumors. DCEUS-based DM-FPI scheme might be a useful tool to help clinicians diagnose and provide suitable therapies for liver tumors. Ivyspring International Publisher 2019-08-14 /pmc/articles/PMC6735512/ /pubmed/31534542 http://dx.doi.org/10.7150/thno.37284 Text en © The author(s) This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/). See http://ivyspring.com/terms for full terms and conditions.
spellingShingle Research Paper
Wang, Diya
Cloutier, Guy
Fan, Yan
Hou, Yanli
Su, Zhe
Su, Qiang
Wan, Mingxi
Automatic Respiratory Gating Hepatic DCEUS-based Dual-phase Multi-parametric Functional Perfusion Imaging using a Derivative Principal Component Analysis
title Automatic Respiratory Gating Hepatic DCEUS-based Dual-phase Multi-parametric Functional Perfusion Imaging using a Derivative Principal Component Analysis
title_full Automatic Respiratory Gating Hepatic DCEUS-based Dual-phase Multi-parametric Functional Perfusion Imaging using a Derivative Principal Component Analysis
title_fullStr Automatic Respiratory Gating Hepatic DCEUS-based Dual-phase Multi-parametric Functional Perfusion Imaging using a Derivative Principal Component Analysis
title_full_unstemmed Automatic Respiratory Gating Hepatic DCEUS-based Dual-phase Multi-parametric Functional Perfusion Imaging using a Derivative Principal Component Analysis
title_short Automatic Respiratory Gating Hepatic DCEUS-based Dual-phase Multi-parametric Functional Perfusion Imaging using a Derivative Principal Component Analysis
title_sort automatic respiratory gating hepatic dceus-based dual-phase multi-parametric functional perfusion imaging using a derivative principal component analysis
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6735512/
https://www.ncbi.nlm.nih.gov/pubmed/31534542
http://dx.doi.org/10.7150/thno.37284
work_keys_str_mv AT wangdiya automaticrespiratorygatinghepaticdceusbaseddualphasemultiparametricfunctionalperfusionimagingusingaderivativeprincipalcomponentanalysis
AT cloutierguy automaticrespiratorygatinghepaticdceusbaseddualphasemultiparametricfunctionalperfusionimagingusingaderivativeprincipalcomponentanalysis
AT fanyan automaticrespiratorygatinghepaticdceusbaseddualphasemultiparametricfunctionalperfusionimagingusingaderivativeprincipalcomponentanalysis
AT houyanli automaticrespiratorygatinghepaticdceusbaseddualphasemultiparametricfunctionalperfusionimagingusingaderivativeprincipalcomponentanalysis
AT suzhe automaticrespiratorygatinghepaticdceusbaseddualphasemultiparametricfunctionalperfusionimagingusingaderivativeprincipalcomponentanalysis
AT suqiang automaticrespiratorygatinghepaticdceusbaseddualphasemultiparametricfunctionalperfusionimagingusingaderivativeprincipalcomponentanalysis
AT wanmingxi automaticrespiratorygatinghepaticdceusbaseddualphasemultiparametricfunctionalperfusionimagingusingaderivativeprincipalcomponentanalysis