Cargando…

A 2-Year Longitudinal Study of Normal Cone Photoreceptor Density

PURPOSE: Despite the potential for adaptive optics scanning light ophthalmoscopy (AOSLO) to quantify retinal disease progression at the cellular level, there remain few longitudinal studies investigating changes in cone density as a measure of disease progression. Here, we undertook a prospective, l...

Descripción completa

Detalles Bibliográficos
Autores principales: Jackson, Kevin, Vergilio, Grace K., Cooper, Robert F., Ying, Gui-Shuang, Morgan, Jessica I. W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6736277/
https://www.ncbi.nlm.nih.gov/pubmed/30943290
http://dx.doi.org/10.1167/iovs.18-25904
_version_ 1783450487086907392
author Jackson, Kevin
Vergilio, Grace K.
Cooper, Robert F.
Ying, Gui-Shuang
Morgan, Jessica I. W.
author_facet Jackson, Kevin
Vergilio, Grace K.
Cooper, Robert F.
Ying, Gui-Shuang
Morgan, Jessica I. W.
author_sort Jackson, Kevin
collection PubMed
description PURPOSE: Despite the potential for adaptive optics scanning light ophthalmoscopy (AOSLO) to quantify retinal disease progression at the cellular level, there remain few longitudinal studies investigating changes in cone density as a measure of disease progression. Here, we undertook a prospective, longitudinal study to investigate the variability of cone density measurements in normal subjects during a 2-year period. METHODS: Fourteen eyes of nine subjects with no known ocular pathology were imaged both at a baseline and a 2-year follow-up visit by using confocal AOSLO at five retinal locations. Two-year affine-registered images were created to minimize the effects of intraframe distortions. Regions of interest were cropped from baseline, 2-year manually aligned, and 2-year affine-registered images. Cones were identified (graded masked) and cone density was extracted. RESULTS: Mean baseline cone density (cones/mm(2)) was 87,300, 62,200, 45,500, 28,700, and 18,200 at 190, 350, 500, 900, and 1500 μm, respectively. The mean difference (± standard deviation [SD]) in cone density from baseline to 2-year affine-registered images was 1400 (1700), 100 (1800), 300 (800), 400 (800), and 1000 (2400) cones/mm(2) at the same locations. The mean difference in cone density during the 2-year period was lower for affine-registered images than manually aligned images. CONCLUSIONS: There was no meaningful change in normal cone density during a 2-year period. Intervisit variability in cone density measurements decreased when intraframe distortions between time points were minimized. This variability must be considered when planning prospective longitudinal clinical trials using changes in cone density as an outcome measure for assessing retinal disease progression.
format Online
Article
Text
id pubmed-6736277
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-67362772019-09-20 A 2-Year Longitudinal Study of Normal Cone Photoreceptor Density Jackson, Kevin Vergilio, Grace K. Cooper, Robert F. Ying, Gui-Shuang Morgan, Jessica I. W. Invest Ophthalmol Vis Sci Visual Psychophysics and Physiological Optics PURPOSE: Despite the potential for adaptive optics scanning light ophthalmoscopy (AOSLO) to quantify retinal disease progression at the cellular level, there remain few longitudinal studies investigating changes in cone density as a measure of disease progression. Here, we undertook a prospective, longitudinal study to investigate the variability of cone density measurements in normal subjects during a 2-year period. METHODS: Fourteen eyes of nine subjects with no known ocular pathology were imaged both at a baseline and a 2-year follow-up visit by using confocal AOSLO at five retinal locations. Two-year affine-registered images were created to minimize the effects of intraframe distortions. Regions of interest were cropped from baseline, 2-year manually aligned, and 2-year affine-registered images. Cones were identified (graded masked) and cone density was extracted. RESULTS: Mean baseline cone density (cones/mm(2)) was 87,300, 62,200, 45,500, 28,700, and 18,200 at 190, 350, 500, 900, and 1500 μm, respectively. The mean difference (± standard deviation [SD]) in cone density from baseline to 2-year affine-registered images was 1400 (1700), 100 (1800), 300 (800), 400 (800), and 1000 (2400) cones/mm(2) at the same locations. The mean difference in cone density during the 2-year period was lower for affine-registered images than manually aligned images. CONCLUSIONS: There was no meaningful change in normal cone density during a 2-year period. Intervisit variability in cone density measurements decreased when intraframe distortions between time points were minimized. This variability must be considered when planning prospective longitudinal clinical trials using changes in cone density as an outcome measure for assessing retinal disease progression. The Association for Research in Vision and Ophthalmology 2019-04 /pmc/articles/PMC6736277/ /pubmed/30943290 http://dx.doi.org/10.1167/iovs.18-25904 Text en Copyright 2019 The Authors http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License.
spellingShingle Visual Psychophysics and Physiological Optics
Jackson, Kevin
Vergilio, Grace K.
Cooper, Robert F.
Ying, Gui-Shuang
Morgan, Jessica I. W.
A 2-Year Longitudinal Study of Normal Cone Photoreceptor Density
title A 2-Year Longitudinal Study of Normal Cone Photoreceptor Density
title_full A 2-Year Longitudinal Study of Normal Cone Photoreceptor Density
title_fullStr A 2-Year Longitudinal Study of Normal Cone Photoreceptor Density
title_full_unstemmed A 2-Year Longitudinal Study of Normal Cone Photoreceptor Density
title_short A 2-Year Longitudinal Study of Normal Cone Photoreceptor Density
title_sort 2-year longitudinal study of normal cone photoreceptor density
topic Visual Psychophysics and Physiological Optics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6736277/
https://www.ncbi.nlm.nih.gov/pubmed/30943290
http://dx.doi.org/10.1167/iovs.18-25904
work_keys_str_mv AT jacksonkevin a2yearlongitudinalstudyofnormalconephotoreceptordensity
AT vergiliogracek a2yearlongitudinalstudyofnormalconephotoreceptordensity
AT cooperrobertf a2yearlongitudinalstudyofnormalconephotoreceptordensity
AT yingguishuang a2yearlongitudinalstudyofnormalconephotoreceptordensity
AT morganjessicaiw a2yearlongitudinalstudyofnormalconephotoreceptordensity
AT jacksonkevin 2yearlongitudinalstudyofnormalconephotoreceptordensity
AT vergiliogracek 2yearlongitudinalstudyofnormalconephotoreceptordensity
AT cooperrobertf 2yearlongitudinalstudyofnormalconephotoreceptordensity
AT yingguishuang 2yearlongitudinalstudyofnormalconephotoreceptordensity
AT morganjessicaiw 2yearlongitudinalstudyofnormalconephotoreceptordensity