Cargando…

Evaluation of COC183B2 antibody targeting ovarian cancer by near-infrared fluorescence imaging

OBJECTIVE: To evaluate the imaging potential of a novel near-infrared (NIR) probe conjugated to COC183B2 monoclonal antibodies (MAb) in ovarian cancer (OC). METHODS: The expression of OC183B2 antigen in OC was determined by immunohistochemical (IHC) staining using tissue microarrays with the H-score...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Chen, Ling, Xinyu, Guo, Yanxiu, Yuan, Cunzhong, Cheng, Hongyan, Ye, Xue, Ma, Ruiqiong, Zhang, Yinli, Li, Yi, Chang, Xiaohong, Kong, Beihua, Liu, Tao, Cui, Heng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6736662/
https://www.ncbi.nlm.nih.gov/pubmed/31564810
http://dx.doi.org/10.21147/j.issn.1000-9604.2019.04.11
Descripción
Sumario:OBJECTIVE: To evaluate the imaging potential of a novel near-infrared (NIR) probe conjugated to COC183B2 monoclonal antibodies (MAb) in ovarian cancer (OC). METHODS: The expression of OC183B2 antigen in OC was determined by immunohistochemical (IHC) staining using tissue microarrays with the H-score system and immunofluorescence (IF) staining of tumor cell lines. Imaging probes with the NIR fluorescent dye cyanine 7 (Cy7) conjugated to COC183B2 Mab were chemically engineered. OC183B2-positive human OC cells (SKOV3-Luc) were injected subcutaneously into BALB/c nude mice. Bioluminescent imaging (BLI) was performed to detect tumor location and growth. COC183B2-Cy7 at 1.1, 3.3, 10, or 30 μg were used for in vivo fluorescence imaging, and phosphate-buffered saline (PBS), free Cy7 dye and mouse isotype immunoglobulin G (IgG)-Cy7 (delivered at the same doses as COC183B2-Cy7) were used as controls. RESULTS: The expression of OC183B2 with a high H-score was more prevalent in OC tissue than fallopian tube (FT) tissue. Among 417 OC patients, the expression of OC183B2 was significantly correlated with the histological subtype, histological grade, residual tumor size, relapse state and survival status. IF staining demonstrated that COC183B2 specifically expressed in SKOV3 cells but not HeLa cells. In vivo NIR fluorescence imaging indicated that COC183B2-Cy7 was mainly distributed in the xenograft and liver with optimal tumor-to-background (T/B) ratios in the xenograft at 30 μg dose. The highest fluorescent signals in the tumor were observed at 96 h post-injection (hpi). Ex vivo fluorescence imaging revealed the fluorescent signals mainly from the tumor and liver. IHC analysis confirmed that xenografts were OC183B2 positive. CONCLUSIONS: COC183B2 is a good candidate for NIR fluorescence imaging and imaging-guided surgery in OC.