Cargando…

Effects of extended powered knee prosthesis stance time via visual feedback on gait symmetry of individuals with unilateral amputation: a preliminary study

BACKGROUND: Establishing gait symmetry is a major aim of amputee rehabilitation and may be more attainable with powered prostheses. Though, based on previous work, we postulate that users transfer a previously-learned motor pattern across devices, limiting the functionality of more advanced prosthes...

Descripción completa

Detalles Bibliográficos
Autores principales: Brandt, Andrea, Riddick, William, Stallrich, Jonathan, Lewek, Michael, Huang, He Helen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6737689/
https://www.ncbi.nlm.nih.gov/pubmed/31511010
http://dx.doi.org/10.1186/s12984-019-0583-z
_version_ 1783450707045646336
author Brandt, Andrea
Riddick, William
Stallrich, Jonathan
Lewek, Michael
Huang, He Helen
author_facet Brandt, Andrea
Riddick, William
Stallrich, Jonathan
Lewek, Michael
Huang, He Helen
author_sort Brandt, Andrea
collection PubMed
description BACKGROUND: Establishing gait symmetry is a major aim of amputee rehabilitation and may be more attainable with powered prostheses. Though, based on previous work, we postulate that users transfer a previously-learned motor pattern across devices, limiting the functionality of more advanced prostheses. The objective of this study was to preliminarily investigate the effect of increased stance time via visual feedback on amputees’ gait symmetry using powered and passive knee prostheses. METHODS: Five individuals with transfemoral amputation or knee disarticulation walked at their self-selected speed on a treadmill. Visual feedback was used to promote an increase in the amputated-limb stance time. Individuals were fit with a commercially-available powered prosthesis by a certified prosthetist and practiced walking during a prior visit. The same protocol was completed with a passive knee and powered knee prosthesis on separate days. We used repeated-measures, two-way ANOVA (alpha = 0.05) to test for significant effects of the feedback and device factors. Our main outcome measures were stance time asymmetry, peak anterior-posterior ground reaction forces, and peak anterior propulsion asymmetry. RESULTS: Increasing the amputated-limb stance time via visual feedback significantly improved the stance time symmetry (p = 0.012) and peak propulsion symmetry (p = 0.036) of individuals walking with both prostheses. With the powered knee prosthesis, the highest feedback target elicited 36% improvement in stance time symmetry, 22% increase in prosthesis-side peak propulsion, and 47% improvement in peak propulsion symmetry compared to a no feedback condition. The changes with feedback were not different with the passive prosthesis, and the main effects of device/ prosthesis type were not statistically different. However, subject by device interactions were significant, indicating individuals did not respond consistently with each device (e.g. prosthesis-side propulsion remained comparable to or was greater with the powered versus passive prosthesis for different subjects). Overall, prosthesis-side peak propulsion averaged across conditions was 31% greater with the powered prosthesis and peak propulsion asymmetry improved by 48% with the powered prosthesis. CONCLUSIONS: Increasing prosthesis-side stance time via visual feedback favorably improved individuals’ temporal and propulsive symmetry. The powered prosthesis commonly enabled greater propulsion, but individuals adapted to each device with varying behavior, requiring further investigation.
format Online
Article
Text
id pubmed-6737689
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-67376892019-09-16 Effects of extended powered knee prosthesis stance time via visual feedback on gait symmetry of individuals with unilateral amputation: a preliminary study Brandt, Andrea Riddick, William Stallrich, Jonathan Lewek, Michael Huang, He Helen J Neuroeng Rehabil Research BACKGROUND: Establishing gait symmetry is a major aim of amputee rehabilitation and may be more attainable with powered prostheses. Though, based on previous work, we postulate that users transfer a previously-learned motor pattern across devices, limiting the functionality of more advanced prostheses. The objective of this study was to preliminarily investigate the effect of increased stance time via visual feedback on amputees’ gait symmetry using powered and passive knee prostheses. METHODS: Five individuals with transfemoral amputation or knee disarticulation walked at their self-selected speed on a treadmill. Visual feedback was used to promote an increase in the amputated-limb stance time. Individuals were fit with a commercially-available powered prosthesis by a certified prosthetist and practiced walking during a prior visit. The same protocol was completed with a passive knee and powered knee prosthesis on separate days. We used repeated-measures, two-way ANOVA (alpha = 0.05) to test for significant effects of the feedback and device factors. Our main outcome measures were stance time asymmetry, peak anterior-posterior ground reaction forces, and peak anterior propulsion asymmetry. RESULTS: Increasing the amputated-limb stance time via visual feedback significantly improved the stance time symmetry (p = 0.012) and peak propulsion symmetry (p = 0.036) of individuals walking with both prostheses. With the powered knee prosthesis, the highest feedback target elicited 36% improvement in stance time symmetry, 22% increase in prosthesis-side peak propulsion, and 47% improvement in peak propulsion symmetry compared to a no feedback condition. The changes with feedback were not different with the passive prosthesis, and the main effects of device/ prosthesis type were not statistically different. However, subject by device interactions were significant, indicating individuals did not respond consistently with each device (e.g. prosthesis-side propulsion remained comparable to or was greater with the powered versus passive prosthesis for different subjects). Overall, prosthesis-side peak propulsion averaged across conditions was 31% greater with the powered prosthesis and peak propulsion asymmetry improved by 48% with the powered prosthesis. CONCLUSIONS: Increasing prosthesis-side stance time via visual feedback favorably improved individuals’ temporal and propulsive symmetry. The powered prosthesis commonly enabled greater propulsion, but individuals adapted to each device with varying behavior, requiring further investigation. BioMed Central 2019-09-11 /pmc/articles/PMC6737689/ /pubmed/31511010 http://dx.doi.org/10.1186/s12984-019-0583-z Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Brandt, Andrea
Riddick, William
Stallrich, Jonathan
Lewek, Michael
Huang, He Helen
Effects of extended powered knee prosthesis stance time via visual feedback on gait symmetry of individuals with unilateral amputation: a preliminary study
title Effects of extended powered knee prosthesis stance time via visual feedback on gait symmetry of individuals with unilateral amputation: a preliminary study
title_full Effects of extended powered knee prosthesis stance time via visual feedback on gait symmetry of individuals with unilateral amputation: a preliminary study
title_fullStr Effects of extended powered knee prosthesis stance time via visual feedback on gait symmetry of individuals with unilateral amputation: a preliminary study
title_full_unstemmed Effects of extended powered knee prosthesis stance time via visual feedback on gait symmetry of individuals with unilateral amputation: a preliminary study
title_short Effects of extended powered knee prosthesis stance time via visual feedback on gait symmetry of individuals with unilateral amputation: a preliminary study
title_sort effects of extended powered knee prosthesis stance time via visual feedback on gait symmetry of individuals with unilateral amputation: a preliminary study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6737689/
https://www.ncbi.nlm.nih.gov/pubmed/31511010
http://dx.doi.org/10.1186/s12984-019-0583-z
work_keys_str_mv AT brandtandrea effectsofextendedpoweredkneeprosthesisstancetimeviavisualfeedbackongaitsymmetryofindividualswithunilateralamputationapreliminarystudy
AT riddickwilliam effectsofextendedpoweredkneeprosthesisstancetimeviavisualfeedbackongaitsymmetryofindividualswithunilateralamputationapreliminarystudy
AT stallrichjonathan effectsofextendedpoweredkneeprosthesisstancetimeviavisualfeedbackongaitsymmetryofindividualswithunilateralamputationapreliminarystudy
AT lewekmichael effectsofextendedpoweredkneeprosthesisstancetimeviavisualfeedbackongaitsymmetryofindividualswithunilateralamputationapreliminarystudy
AT huanghehelen effectsofextendedpoweredkneeprosthesisstancetimeviavisualfeedbackongaitsymmetryofindividualswithunilateralamputationapreliminarystudy