Cargando…
Clinical and Technical Characteristics of Coronary Angiography and Percutaneous Coronary Interventions Performed before and after Transcatheter Aortic Valve Replacement with a Balloon-Expandable Valve
OBJECTIVES: To report on the feasibility and technical differences between coronary procedures performed before and after TAVR with the balloon-expandable Edwards-SAPIEN or the SAPIEN XT valves. BACKGROUND: Coronary artery disease (CAD) and aortic stenosis often coexist. Transcatheter aortic valve r...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6738988/ https://www.ncbi.nlm.nih.gov/pubmed/31772527 http://dx.doi.org/10.1155/2019/3579671 |
_version_ | 1783450878064197632 |
---|---|
author | Ferreira-Neto, Alfredo Nunes Puri, Rishi Asmarats, Lluis Vilalta, Victoria Guimaraes, Leonardo Delarochellière, Robert Paradis, Jean-Michel Mohammadi, Siamak Dumont, Eric Rodés-Cabau, Josep |
author_facet | Ferreira-Neto, Alfredo Nunes Puri, Rishi Asmarats, Lluis Vilalta, Victoria Guimaraes, Leonardo Delarochellière, Robert Paradis, Jean-Michel Mohammadi, Siamak Dumont, Eric Rodés-Cabau, Josep |
author_sort | Ferreira-Neto, Alfredo Nunes |
collection | PubMed |
description | OBJECTIVES: To report on the feasibility and technical differences between coronary procedures performed before and after TAVR with the balloon-expandable Edwards-SAPIEN or the SAPIEN XT valves. BACKGROUND: Coronary artery disease (CAD) and aortic stenosis often coexist. Transcatheter aortic valve replacement (TAVR) is emerging as a treatment for younger and lower surgical risk patients who might not present with clinically evident CAD before TAVR. The demand for performing post-TAVR coronary angiograms (CAs) and percutaneous coronary interventions (PCIs) will thus increase, posing new technical challenges. METHODS: Over 1000 TAVRs were performed at the Quebec Heart and Lung Institute, of which 616 with the abovementioned valves. Of these, 28 patients had an analyzable pre- and post-TAVR CAs and 13 patients had pre- and post-TAVR PCIs performed. Procedural characteristics were gathered from all coronary procedures and subsequently compared amongst the same type of procedure performed at these two distinct time periods. RESULTS: Neither CAs‐nor PCIs‐performed after valve implantation revealed significant differences regarding arterial access site, catheter diameter, number of diagnostic or guiding catheters used, procedural duration, fluoroscopy time, or achievement of selective coronary injection. Lesion location and classification, as well as the preference of using a drug-eluting stent, remained unchanged. During post-TAVR CA, the amount of contrast delivered and the radiation dose area product were significantly lower compared with pre-TAVR CA values. CONCLUSIONS: Performance of CA and PCI after TAVR with a balloon-expandable valve appears unaffected by its presence. |
format | Online Article Text |
id | pubmed-6738988 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-67389882019-09-17 Clinical and Technical Characteristics of Coronary Angiography and Percutaneous Coronary Interventions Performed before and after Transcatheter Aortic Valve Replacement with a Balloon-Expandable Valve Ferreira-Neto, Alfredo Nunes Puri, Rishi Asmarats, Lluis Vilalta, Victoria Guimaraes, Leonardo Delarochellière, Robert Paradis, Jean-Michel Mohammadi, Siamak Dumont, Eric Rodés-Cabau, Josep J Interv Cardiol Research Article OBJECTIVES: To report on the feasibility and technical differences between coronary procedures performed before and after TAVR with the balloon-expandable Edwards-SAPIEN or the SAPIEN XT valves. BACKGROUND: Coronary artery disease (CAD) and aortic stenosis often coexist. Transcatheter aortic valve replacement (TAVR) is emerging as a treatment for younger and lower surgical risk patients who might not present with clinically evident CAD before TAVR. The demand for performing post-TAVR coronary angiograms (CAs) and percutaneous coronary interventions (PCIs) will thus increase, posing new technical challenges. METHODS: Over 1000 TAVRs were performed at the Quebec Heart and Lung Institute, of which 616 with the abovementioned valves. Of these, 28 patients had an analyzable pre- and post-TAVR CAs and 13 patients had pre- and post-TAVR PCIs performed. Procedural characteristics were gathered from all coronary procedures and subsequently compared amongst the same type of procedure performed at these two distinct time periods. RESULTS: Neither CAs‐nor PCIs‐performed after valve implantation revealed significant differences regarding arterial access site, catheter diameter, number of diagnostic or guiding catheters used, procedural duration, fluoroscopy time, or achievement of selective coronary injection. Lesion location and classification, as well as the preference of using a drug-eluting stent, remained unchanged. During post-TAVR CA, the amount of contrast delivered and the radiation dose area product were significantly lower compared with pre-TAVR CA values. CONCLUSIONS: Performance of CA and PCI after TAVR with a balloon-expandable valve appears unaffected by its presence. Hindawi 2019-08-08 /pmc/articles/PMC6738988/ /pubmed/31772527 http://dx.doi.org/10.1155/2019/3579671 Text en Copyright © 2019 Alfredo Nunes Ferreira-Neto et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Ferreira-Neto, Alfredo Nunes Puri, Rishi Asmarats, Lluis Vilalta, Victoria Guimaraes, Leonardo Delarochellière, Robert Paradis, Jean-Michel Mohammadi, Siamak Dumont, Eric Rodés-Cabau, Josep Clinical and Technical Characteristics of Coronary Angiography and Percutaneous Coronary Interventions Performed before and after Transcatheter Aortic Valve Replacement with a Balloon-Expandable Valve |
title | Clinical and Technical Characteristics of Coronary Angiography and Percutaneous Coronary Interventions Performed before and after Transcatheter Aortic Valve Replacement with a Balloon-Expandable Valve |
title_full | Clinical and Technical Characteristics of Coronary Angiography and Percutaneous Coronary Interventions Performed before and after Transcatheter Aortic Valve Replacement with a Balloon-Expandable Valve |
title_fullStr | Clinical and Technical Characteristics of Coronary Angiography and Percutaneous Coronary Interventions Performed before and after Transcatheter Aortic Valve Replacement with a Balloon-Expandable Valve |
title_full_unstemmed | Clinical and Technical Characteristics of Coronary Angiography and Percutaneous Coronary Interventions Performed before and after Transcatheter Aortic Valve Replacement with a Balloon-Expandable Valve |
title_short | Clinical and Technical Characteristics of Coronary Angiography and Percutaneous Coronary Interventions Performed before and after Transcatheter Aortic Valve Replacement with a Balloon-Expandable Valve |
title_sort | clinical and technical characteristics of coronary angiography and percutaneous coronary interventions performed before and after transcatheter aortic valve replacement with a balloon-expandable valve |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6738988/ https://www.ncbi.nlm.nih.gov/pubmed/31772527 http://dx.doi.org/10.1155/2019/3579671 |
work_keys_str_mv | AT ferreiranetoalfredonunes clinicalandtechnicalcharacteristicsofcoronaryangiographyandpercutaneouscoronaryinterventionsperformedbeforeandaftertranscatheteraorticvalvereplacementwithaballoonexpandablevalve AT puririshi clinicalandtechnicalcharacteristicsofcoronaryangiographyandpercutaneouscoronaryinterventionsperformedbeforeandaftertranscatheteraorticvalvereplacementwithaballoonexpandablevalve AT asmaratslluis clinicalandtechnicalcharacteristicsofcoronaryangiographyandpercutaneouscoronaryinterventionsperformedbeforeandaftertranscatheteraorticvalvereplacementwithaballoonexpandablevalve AT vilaltavictoria clinicalandtechnicalcharacteristicsofcoronaryangiographyandpercutaneouscoronaryinterventionsperformedbeforeandaftertranscatheteraorticvalvereplacementwithaballoonexpandablevalve AT guimaraesleonardo clinicalandtechnicalcharacteristicsofcoronaryangiographyandpercutaneouscoronaryinterventionsperformedbeforeandaftertranscatheteraorticvalvereplacementwithaballoonexpandablevalve AT delarochelliererobert clinicalandtechnicalcharacteristicsofcoronaryangiographyandpercutaneouscoronaryinterventionsperformedbeforeandaftertranscatheteraorticvalvereplacementwithaballoonexpandablevalve AT paradisjeanmichel clinicalandtechnicalcharacteristicsofcoronaryangiographyandpercutaneouscoronaryinterventionsperformedbeforeandaftertranscatheteraorticvalvereplacementwithaballoonexpandablevalve AT mohammadisiamak clinicalandtechnicalcharacteristicsofcoronaryangiographyandpercutaneouscoronaryinterventionsperformedbeforeandaftertranscatheteraorticvalvereplacementwithaballoonexpandablevalve AT dumonteric clinicalandtechnicalcharacteristicsofcoronaryangiographyandpercutaneouscoronaryinterventionsperformedbeforeandaftertranscatheteraorticvalvereplacementwithaballoonexpandablevalve AT rodescabaujosep clinicalandtechnicalcharacteristicsofcoronaryangiographyandpercutaneouscoronaryinterventionsperformedbeforeandaftertranscatheteraorticvalvereplacementwithaballoonexpandablevalve |