Cargando…
Intravenous Infusion Administration: A Comparative Study of Practices and Errors Between the United States and England and Their Implications for Patient Safety
INTRODUCTION: Intravenous medication administration is widely reported to be error prone. Technologies such as smart pumps have been introduced with a view to reducing these errors. An international comparison could provide evidence of their effectiveness, including consideration of contextual facto...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6739270/ https://www.ncbi.nlm.nih.gov/pubmed/31197746 http://dx.doi.org/10.1007/s40264-019-00841-2 |
_version_ | 1783450908853534720 |
---|---|
author | Blandford, Ann Dykes, Patricia C. Franklin, Bryony Dean Furniss, Dominic Galal-Edeen, Galal H. Schnock, Kumiko O. Bates, David W. |
author_facet | Blandford, Ann Dykes, Patricia C. Franklin, Bryony Dean Furniss, Dominic Galal-Edeen, Galal H. Schnock, Kumiko O. Bates, David W. |
author_sort | Blandford, Ann |
collection | PubMed |
description | INTRODUCTION: Intravenous medication administration is widely reported to be error prone. Technologies such as smart pumps have been introduced with a view to reducing these errors. An international comparison could provide evidence of their effectiveness, including consideration of contextual factors such as regulatory systems and local cultures. OBJECTIVES: The aim of this study was to investigate similarities and differences in practices and error types involving intravenous medication administration in the United States and England, and summarise methodological differences necessary to perform these parallel studies. METHODS: We drew on findings of separate point prevalence studies conducted across hospitals in each country. In these, we compared what was being administered at the time of observation with the prescription and relevant policies, errors were classified by type and severity, and proportions of infusions featuring each error type were calculated. We also reviewed what adaptations to the US protocol were needed for England. Authors independently reviewed findings from both studies and proposed themes for comparison. In online meetings, each country’s research team clarified assumptions and explained their findings. RESULTS: Key themes included commonalities and contrasts in methods, findings, practices and policies. Although US sites made greater use of smart infusion devices, and had more precisely defined requirements around infusion device use, patterns of errors were similar. Differences among clinical contexts within each country were as marked as differences across countries. Regulatory and quality control systems shape practices, but causal relationships are complex. CONCLUSION: Infusion administration is a complex adaptive system with multiple interacting agents (professionals, patients, software systems, etc.) that respond in rich ways to their environments; safety depends on complex, interrelated factors. |
format | Online Article Text |
id | pubmed-6739270 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-67392702019-09-25 Intravenous Infusion Administration: A Comparative Study of Practices and Errors Between the United States and England and Their Implications for Patient Safety Blandford, Ann Dykes, Patricia C. Franklin, Bryony Dean Furniss, Dominic Galal-Edeen, Galal H. Schnock, Kumiko O. Bates, David W. Drug Saf Short Communication INTRODUCTION: Intravenous medication administration is widely reported to be error prone. Technologies such as smart pumps have been introduced with a view to reducing these errors. An international comparison could provide evidence of their effectiveness, including consideration of contextual factors such as regulatory systems and local cultures. OBJECTIVES: The aim of this study was to investigate similarities and differences in practices and error types involving intravenous medication administration in the United States and England, and summarise methodological differences necessary to perform these parallel studies. METHODS: We drew on findings of separate point prevalence studies conducted across hospitals in each country. In these, we compared what was being administered at the time of observation with the prescription and relevant policies, errors were classified by type and severity, and proportions of infusions featuring each error type were calculated. We also reviewed what adaptations to the US protocol were needed for England. Authors independently reviewed findings from both studies and proposed themes for comparison. In online meetings, each country’s research team clarified assumptions and explained their findings. RESULTS: Key themes included commonalities and contrasts in methods, findings, practices and policies. Although US sites made greater use of smart infusion devices, and had more precisely defined requirements around infusion device use, patterns of errors were similar. Differences among clinical contexts within each country were as marked as differences across countries. Regulatory and quality control systems shape practices, but causal relationships are complex. CONCLUSION: Infusion administration is a complex adaptive system with multiple interacting agents (professionals, patients, software systems, etc.) that respond in rich ways to their environments; safety depends on complex, interrelated factors. Springer International Publishing 2019-06-13 2019 /pmc/articles/PMC6739270/ /pubmed/31197746 http://dx.doi.org/10.1007/s40264-019-00841-2 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/), which permits any noncommercial use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Short Communication Blandford, Ann Dykes, Patricia C. Franklin, Bryony Dean Furniss, Dominic Galal-Edeen, Galal H. Schnock, Kumiko O. Bates, David W. Intravenous Infusion Administration: A Comparative Study of Practices and Errors Between the United States and England and Their Implications for Patient Safety |
title | Intravenous Infusion Administration: A Comparative Study of Practices and Errors Between the United States and England and Their Implications for Patient Safety |
title_full | Intravenous Infusion Administration: A Comparative Study of Practices and Errors Between the United States and England and Their Implications for Patient Safety |
title_fullStr | Intravenous Infusion Administration: A Comparative Study of Practices and Errors Between the United States and England and Their Implications for Patient Safety |
title_full_unstemmed | Intravenous Infusion Administration: A Comparative Study of Practices and Errors Between the United States and England and Their Implications for Patient Safety |
title_short | Intravenous Infusion Administration: A Comparative Study of Practices and Errors Between the United States and England and Their Implications for Patient Safety |
title_sort | intravenous infusion administration: a comparative study of practices and errors between the united states and england and their implications for patient safety |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6739270/ https://www.ncbi.nlm.nih.gov/pubmed/31197746 http://dx.doi.org/10.1007/s40264-019-00841-2 |
work_keys_str_mv | AT blandfordann intravenousinfusionadministrationacomparativestudyofpracticesanderrorsbetweentheunitedstatesandenglandandtheirimplicationsforpatientsafety AT dykespatriciac intravenousinfusionadministrationacomparativestudyofpracticesanderrorsbetweentheunitedstatesandenglandandtheirimplicationsforpatientsafety AT franklinbryonydean intravenousinfusionadministrationacomparativestudyofpracticesanderrorsbetweentheunitedstatesandenglandandtheirimplicationsforpatientsafety AT furnissdominic intravenousinfusionadministrationacomparativestudyofpracticesanderrorsbetweentheunitedstatesandenglandandtheirimplicationsforpatientsafety AT galaledeengalalh intravenousinfusionadministrationacomparativestudyofpracticesanderrorsbetweentheunitedstatesandenglandandtheirimplicationsforpatientsafety AT schnockkumikoo intravenousinfusionadministrationacomparativestudyofpracticesanderrorsbetweentheunitedstatesandenglandandtheirimplicationsforpatientsafety AT batesdavidw intravenousinfusionadministrationacomparativestudyofpracticesanderrorsbetweentheunitedstatesandenglandandtheirimplicationsforpatientsafety |