Cargando…

Safety and Long-Term Efficacy of Drug-Coated Balloon Angioplasty following Rotational Atherectomy for Severely Calcified Coronary Lesions Compared with New Generation Drug-Eluting Stents

OBJECTIVES: This study sought to assess the safety and long-term efficacy of drug-coated balloons (DCB) following aggressive intracoronary image-guided rotational atherectomy (iRA) for severe coronary artery calcification (CAC), and to compare this strategy with new generation drug-eluting stents (n...

Descripción completa

Detalles Bibliográficos
Autores principales: Ueno, Katsumi, Morita, Norihiko, Kojima, Yoshinobu, Takahashi, Hiroshi, Kawasaki, Masanori, Ito, Ryuta, Kondo, Hiroki, Minatoguchi, Shingo, Yoshida, Tamami, Hashimoto, Yasumasa, Tatsumi, Tomohiko, Kitamura, Tomoya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6739772/
https://www.ncbi.nlm.nih.gov/pubmed/31772551
http://dx.doi.org/10.1155/2019/9094178
_version_ 1783450994343936000
author Ueno, Katsumi
Morita, Norihiko
Kojima, Yoshinobu
Takahashi, Hiroshi
Kawasaki, Masanori
Ito, Ryuta
Kondo, Hiroki
Minatoguchi, Shingo
Yoshida, Tamami
Hashimoto, Yasumasa
Tatsumi, Tomohiko
Kitamura, Tomoya
author_facet Ueno, Katsumi
Morita, Norihiko
Kojima, Yoshinobu
Takahashi, Hiroshi
Kawasaki, Masanori
Ito, Ryuta
Kondo, Hiroki
Minatoguchi, Shingo
Yoshida, Tamami
Hashimoto, Yasumasa
Tatsumi, Tomohiko
Kitamura, Tomoya
author_sort Ueno, Katsumi
collection PubMed
description OBJECTIVES: This study sought to assess the safety and long-term efficacy of drug-coated balloons (DCB) following aggressive intracoronary image-guided rotational atherectomy (iRA) for severe coronary artery calcification (CAC), and to compare this strategy with new generation drug-eluting stents (nDES) following iRA. BACKGROUND: Ischemic events following the treatment of CAC is still relatively high. Thus, more innovative strategies are required. METHODS: We evaluated 123 consecutive patients (166 lesions) with de novo CAC undergoing an iRA (burr size; 0.7 of the mean reference diameter by intracoronary imaging) followed by DCB (DCB-iRA; 54 patients, 68 lesions) or nDES (nDES-iRA; 69 patients, 98 lesions). Follow-up angiography was obtained at > 6 months. RESULTS: The target vessels (right coronary and circumflex), bifurcation (67.6% versus 47.9%), reference diameter (2.28mm versus 2.49mm), and lesion length (11.89mm versus 18.78mm) were significantly different between the two groups. The median follow-up was 732 days. TLR and TVR in DCB-iRA and nDES-iRA at 3 years were similar: 15.6% versus 16.3% (P=0.99) and 15.6% versus 23.3% (P=0.38). In 41 well-matched lesion pairs after propensity score analysis, the cumulative incidence of TLR and TVR in DCB-iRA and nDES-iRA at 3 years was 12.9% versus 16.3% (P=0.70) and 12.9% versus 26.1% (P=0.17), respectively. On QCA analysis, although the acute gain was smaller in DCB-iRA (0.85 mm versus 1.53 mm, P<0.001), the minimum lumen diameter at follow-up was similar (1.69 mm versus 1.87 mm, P=0.29). The late lumen loss was lower (0.09 mm versus 0.52 mm, P=0.009) in DCB-iRA. CONCLUSIONS: DCB-iRA is feasible for CAC.
format Online
Article
Text
id pubmed-6739772
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-67397722019-09-17 Safety and Long-Term Efficacy of Drug-Coated Balloon Angioplasty following Rotational Atherectomy for Severely Calcified Coronary Lesions Compared with New Generation Drug-Eluting Stents Ueno, Katsumi Morita, Norihiko Kojima, Yoshinobu Takahashi, Hiroshi Kawasaki, Masanori Ito, Ryuta Kondo, Hiroki Minatoguchi, Shingo Yoshida, Tamami Hashimoto, Yasumasa Tatsumi, Tomohiko Kitamura, Tomoya J Interv Cardiol Research Article OBJECTIVES: This study sought to assess the safety and long-term efficacy of drug-coated balloons (DCB) following aggressive intracoronary image-guided rotational atherectomy (iRA) for severe coronary artery calcification (CAC), and to compare this strategy with new generation drug-eluting stents (nDES) following iRA. BACKGROUND: Ischemic events following the treatment of CAC is still relatively high. Thus, more innovative strategies are required. METHODS: We evaluated 123 consecutive patients (166 lesions) with de novo CAC undergoing an iRA (burr size; 0.7 of the mean reference diameter by intracoronary imaging) followed by DCB (DCB-iRA; 54 patients, 68 lesions) or nDES (nDES-iRA; 69 patients, 98 lesions). Follow-up angiography was obtained at > 6 months. RESULTS: The target vessels (right coronary and circumflex), bifurcation (67.6% versus 47.9%), reference diameter (2.28mm versus 2.49mm), and lesion length (11.89mm versus 18.78mm) were significantly different between the two groups. The median follow-up was 732 days. TLR and TVR in DCB-iRA and nDES-iRA at 3 years were similar: 15.6% versus 16.3% (P=0.99) and 15.6% versus 23.3% (P=0.38). In 41 well-matched lesion pairs after propensity score analysis, the cumulative incidence of TLR and TVR in DCB-iRA and nDES-iRA at 3 years was 12.9% versus 16.3% (P=0.70) and 12.9% versus 26.1% (P=0.17), respectively. On QCA analysis, although the acute gain was smaller in DCB-iRA (0.85 mm versus 1.53 mm, P<0.001), the minimum lumen diameter at follow-up was similar (1.69 mm versus 1.87 mm, P=0.29). The late lumen loss was lower (0.09 mm versus 0.52 mm, P=0.009) in DCB-iRA. CONCLUSIONS: DCB-iRA is feasible for CAC. Hindawi 2019-03-13 /pmc/articles/PMC6739772/ /pubmed/31772551 http://dx.doi.org/10.1155/2019/9094178 Text en Copyright © 2019 Katsumi Ueno et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ueno, Katsumi
Morita, Norihiko
Kojima, Yoshinobu
Takahashi, Hiroshi
Kawasaki, Masanori
Ito, Ryuta
Kondo, Hiroki
Minatoguchi, Shingo
Yoshida, Tamami
Hashimoto, Yasumasa
Tatsumi, Tomohiko
Kitamura, Tomoya
Safety and Long-Term Efficacy of Drug-Coated Balloon Angioplasty following Rotational Atherectomy for Severely Calcified Coronary Lesions Compared with New Generation Drug-Eluting Stents
title Safety and Long-Term Efficacy of Drug-Coated Balloon Angioplasty following Rotational Atherectomy for Severely Calcified Coronary Lesions Compared with New Generation Drug-Eluting Stents
title_full Safety and Long-Term Efficacy of Drug-Coated Balloon Angioplasty following Rotational Atherectomy for Severely Calcified Coronary Lesions Compared with New Generation Drug-Eluting Stents
title_fullStr Safety and Long-Term Efficacy of Drug-Coated Balloon Angioplasty following Rotational Atherectomy for Severely Calcified Coronary Lesions Compared with New Generation Drug-Eluting Stents
title_full_unstemmed Safety and Long-Term Efficacy of Drug-Coated Balloon Angioplasty following Rotational Atherectomy for Severely Calcified Coronary Lesions Compared with New Generation Drug-Eluting Stents
title_short Safety and Long-Term Efficacy of Drug-Coated Balloon Angioplasty following Rotational Atherectomy for Severely Calcified Coronary Lesions Compared with New Generation Drug-Eluting Stents
title_sort safety and long-term efficacy of drug-coated balloon angioplasty following rotational atherectomy for severely calcified coronary lesions compared with new generation drug-eluting stents
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6739772/
https://www.ncbi.nlm.nih.gov/pubmed/31772551
http://dx.doi.org/10.1155/2019/9094178
work_keys_str_mv AT uenokatsumi safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents
AT moritanorihiko safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents
AT kojimayoshinobu safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents
AT takahashihiroshi safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents
AT kawasakimasanori safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents
AT itoryuta safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents
AT kondohiroki safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents
AT minatoguchishingo safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents
AT yoshidatamami safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents
AT hashimotoyasumasa safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents
AT tatsumitomohiko safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents
AT kitamuratomoya safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents