Cargando…
Safety and Long-Term Efficacy of Drug-Coated Balloon Angioplasty following Rotational Atherectomy for Severely Calcified Coronary Lesions Compared with New Generation Drug-Eluting Stents
OBJECTIVES: This study sought to assess the safety and long-term efficacy of drug-coated balloons (DCB) following aggressive intracoronary image-guided rotational atherectomy (iRA) for severe coronary artery calcification (CAC), and to compare this strategy with new generation drug-eluting stents (n...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6739772/ https://www.ncbi.nlm.nih.gov/pubmed/31772551 http://dx.doi.org/10.1155/2019/9094178 |
_version_ | 1783450994343936000 |
---|---|
author | Ueno, Katsumi Morita, Norihiko Kojima, Yoshinobu Takahashi, Hiroshi Kawasaki, Masanori Ito, Ryuta Kondo, Hiroki Minatoguchi, Shingo Yoshida, Tamami Hashimoto, Yasumasa Tatsumi, Tomohiko Kitamura, Tomoya |
author_facet | Ueno, Katsumi Morita, Norihiko Kojima, Yoshinobu Takahashi, Hiroshi Kawasaki, Masanori Ito, Ryuta Kondo, Hiroki Minatoguchi, Shingo Yoshida, Tamami Hashimoto, Yasumasa Tatsumi, Tomohiko Kitamura, Tomoya |
author_sort | Ueno, Katsumi |
collection | PubMed |
description | OBJECTIVES: This study sought to assess the safety and long-term efficacy of drug-coated balloons (DCB) following aggressive intracoronary image-guided rotational atherectomy (iRA) for severe coronary artery calcification (CAC), and to compare this strategy with new generation drug-eluting stents (nDES) following iRA. BACKGROUND: Ischemic events following the treatment of CAC is still relatively high. Thus, more innovative strategies are required. METHODS: We evaluated 123 consecutive patients (166 lesions) with de novo CAC undergoing an iRA (burr size; 0.7 of the mean reference diameter by intracoronary imaging) followed by DCB (DCB-iRA; 54 patients, 68 lesions) or nDES (nDES-iRA; 69 patients, 98 lesions). Follow-up angiography was obtained at > 6 months. RESULTS: The target vessels (right coronary and circumflex), bifurcation (67.6% versus 47.9%), reference diameter (2.28mm versus 2.49mm), and lesion length (11.89mm versus 18.78mm) were significantly different between the two groups. The median follow-up was 732 days. TLR and TVR in DCB-iRA and nDES-iRA at 3 years were similar: 15.6% versus 16.3% (P=0.99) and 15.6% versus 23.3% (P=0.38). In 41 well-matched lesion pairs after propensity score analysis, the cumulative incidence of TLR and TVR in DCB-iRA and nDES-iRA at 3 years was 12.9% versus 16.3% (P=0.70) and 12.9% versus 26.1% (P=0.17), respectively. On QCA analysis, although the acute gain was smaller in DCB-iRA (0.85 mm versus 1.53 mm, P<0.001), the minimum lumen diameter at follow-up was similar (1.69 mm versus 1.87 mm, P=0.29). The late lumen loss was lower (0.09 mm versus 0.52 mm, P=0.009) in DCB-iRA. CONCLUSIONS: DCB-iRA is feasible for CAC. |
format | Online Article Text |
id | pubmed-6739772 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-67397722019-09-17 Safety and Long-Term Efficacy of Drug-Coated Balloon Angioplasty following Rotational Atherectomy for Severely Calcified Coronary Lesions Compared with New Generation Drug-Eluting Stents Ueno, Katsumi Morita, Norihiko Kojima, Yoshinobu Takahashi, Hiroshi Kawasaki, Masanori Ito, Ryuta Kondo, Hiroki Minatoguchi, Shingo Yoshida, Tamami Hashimoto, Yasumasa Tatsumi, Tomohiko Kitamura, Tomoya J Interv Cardiol Research Article OBJECTIVES: This study sought to assess the safety and long-term efficacy of drug-coated balloons (DCB) following aggressive intracoronary image-guided rotational atherectomy (iRA) for severe coronary artery calcification (CAC), and to compare this strategy with new generation drug-eluting stents (nDES) following iRA. BACKGROUND: Ischemic events following the treatment of CAC is still relatively high. Thus, more innovative strategies are required. METHODS: We evaluated 123 consecutive patients (166 lesions) with de novo CAC undergoing an iRA (burr size; 0.7 of the mean reference diameter by intracoronary imaging) followed by DCB (DCB-iRA; 54 patients, 68 lesions) or nDES (nDES-iRA; 69 patients, 98 lesions). Follow-up angiography was obtained at > 6 months. RESULTS: The target vessels (right coronary and circumflex), bifurcation (67.6% versus 47.9%), reference diameter (2.28mm versus 2.49mm), and lesion length (11.89mm versus 18.78mm) were significantly different between the two groups. The median follow-up was 732 days. TLR and TVR in DCB-iRA and nDES-iRA at 3 years were similar: 15.6% versus 16.3% (P=0.99) and 15.6% versus 23.3% (P=0.38). In 41 well-matched lesion pairs after propensity score analysis, the cumulative incidence of TLR and TVR in DCB-iRA and nDES-iRA at 3 years was 12.9% versus 16.3% (P=0.70) and 12.9% versus 26.1% (P=0.17), respectively. On QCA analysis, although the acute gain was smaller in DCB-iRA (0.85 mm versus 1.53 mm, P<0.001), the minimum lumen diameter at follow-up was similar (1.69 mm versus 1.87 mm, P=0.29). The late lumen loss was lower (0.09 mm versus 0.52 mm, P=0.009) in DCB-iRA. CONCLUSIONS: DCB-iRA is feasible for CAC. Hindawi 2019-03-13 /pmc/articles/PMC6739772/ /pubmed/31772551 http://dx.doi.org/10.1155/2019/9094178 Text en Copyright © 2019 Katsumi Ueno et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Ueno, Katsumi Morita, Norihiko Kojima, Yoshinobu Takahashi, Hiroshi Kawasaki, Masanori Ito, Ryuta Kondo, Hiroki Minatoguchi, Shingo Yoshida, Tamami Hashimoto, Yasumasa Tatsumi, Tomohiko Kitamura, Tomoya Safety and Long-Term Efficacy of Drug-Coated Balloon Angioplasty following Rotational Atherectomy for Severely Calcified Coronary Lesions Compared with New Generation Drug-Eluting Stents |
title | Safety and Long-Term Efficacy of Drug-Coated Balloon Angioplasty following Rotational Atherectomy for Severely Calcified Coronary Lesions Compared with New Generation Drug-Eluting Stents |
title_full | Safety and Long-Term Efficacy of Drug-Coated Balloon Angioplasty following Rotational Atherectomy for Severely Calcified Coronary Lesions Compared with New Generation Drug-Eluting Stents |
title_fullStr | Safety and Long-Term Efficacy of Drug-Coated Balloon Angioplasty following Rotational Atherectomy for Severely Calcified Coronary Lesions Compared with New Generation Drug-Eluting Stents |
title_full_unstemmed | Safety and Long-Term Efficacy of Drug-Coated Balloon Angioplasty following Rotational Atherectomy for Severely Calcified Coronary Lesions Compared with New Generation Drug-Eluting Stents |
title_short | Safety and Long-Term Efficacy of Drug-Coated Balloon Angioplasty following Rotational Atherectomy for Severely Calcified Coronary Lesions Compared with New Generation Drug-Eluting Stents |
title_sort | safety and long-term efficacy of drug-coated balloon angioplasty following rotational atherectomy for severely calcified coronary lesions compared with new generation drug-eluting stents |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6739772/ https://www.ncbi.nlm.nih.gov/pubmed/31772551 http://dx.doi.org/10.1155/2019/9094178 |
work_keys_str_mv | AT uenokatsumi safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents AT moritanorihiko safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents AT kojimayoshinobu safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents AT takahashihiroshi safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents AT kawasakimasanori safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents AT itoryuta safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents AT kondohiroki safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents AT minatoguchishingo safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents AT yoshidatamami safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents AT hashimotoyasumasa safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents AT tatsumitomohiko safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents AT kitamuratomoya safetyandlongtermefficacyofdrugcoatedballoonangioplastyfollowingrotationalatherectomyforseverelycalcifiedcoronarylesionscomparedwithnewgenerationdrugelutingstents |