Cargando…

Estimation of Absorbed Dose of the Thyroid Gland in Patients Undergoing 64-Slice Head Computed Tomography and Comparison the Results with ImPACT Software and Computed Tomography Scan Dose Index

Thyroid exposure to radiation in brain computed tomography (CT) scan is of great value since it is considered as a vital organ. This study aimed to investigate the absorbed dose of thyroid by various protocols of head CT in patients referring to 64-slice CT scan center and to compare the values with...

Descripción completa

Detalles Bibliográficos
Autores principales: Maziar, Asghar, Paydar, Reza, Azadbakht, Ghazal, Shahbazi-Gahrouei, Daryoush
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6743239/
https://www.ncbi.nlm.nih.gov/pubmed/31544059
http://dx.doi.org/10.4103/jmss.JMSS_40_18
_version_ 1783451247065432064
author Maziar, Asghar
Paydar, Reza
Azadbakht, Ghazal
Shahbazi-Gahrouei, Daryoush
author_facet Maziar, Asghar
Paydar, Reza
Azadbakht, Ghazal
Shahbazi-Gahrouei, Daryoush
author_sort Maziar, Asghar
collection PubMed
description Thyroid exposure to radiation in brain computed tomography (CT) scan is of great value since it is considered as a vital organ. This study aimed to investigate the absorbed dose of thyroid by various protocols of head CT in patients referring to 64-slice CT scan center and to compare the values with the calculated dose by imaging performance and assessment of CT (ImPACT) method. Also, the values of CT scan dose index (CTDI) were calculated with semiconductor detector. In this cross-sectional study, 120 outpatients including three groups of forty individuals over 40 years old referring to the hospital radiology centers in Tehran for head CT were chosen and 3 thermo-luminescence dosimeter (TLD-GR200) were applied on thyroid gland of each patient. For brain CT, Absorbed and effective doses of thyroid gland were calculated by ImPACT software. In addition, semiconductor detector in head CTDI phantom calculated CTDI for the applied protocols. Mean effective dose of thyroid gland in brain scan group was calculated by TLD and ImPACT software which showed no significant difference (P < 0.001). Mean effective dose of thyroid gland in unidirectional and bi-directional sinus scan by TLD and ImPACT software were different significantly (P < 0.001). Also, the differences between CTDI values shown by brain and sinus scan protocol with semiconductor detector and those CTDI were significant (P < 0.001). The calculated values of absorbed dose and effective doses of thyroid by TLD and ImPACT software were not significantly different. Mean effective dose calculated for thyroid gland in head scans by TLD and ImPACT was less than the annual permissive level for thyroid gland suggested by International Committee on Radiological Protection. In this study, calculated values of thyroid effective dose in brain scan with 64-slice scanner were less than the calculated values in a similar study.
format Online
Article
Text
id pubmed-6743239
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-67432392019-09-20 Estimation of Absorbed Dose of the Thyroid Gland in Patients Undergoing 64-Slice Head Computed Tomography and Comparison the Results with ImPACT Software and Computed Tomography Scan Dose Index Maziar, Asghar Paydar, Reza Azadbakht, Ghazal Shahbazi-Gahrouei, Daryoush J Med Signals Sens Short Communication Thyroid exposure to radiation in brain computed tomography (CT) scan is of great value since it is considered as a vital organ. This study aimed to investigate the absorbed dose of thyroid by various protocols of head CT in patients referring to 64-slice CT scan center and to compare the values with the calculated dose by imaging performance and assessment of CT (ImPACT) method. Also, the values of CT scan dose index (CTDI) were calculated with semiconductor detector. In this cross-sectional study, 120 outpatients including three groups of forty individuals over 40 years old referring to the hospital radiology centers in Tehran for head CT were chosen and 3 thermo-luminescence dosimeter (TLD-GR200) were applied on thyroid gland of each patient. For brain CT, Absorbed and effective doses of thyroid gland were calculated by ImPACT software. In addition, semiconductor detector in head CTDI phantom calculated CTDI for the applied protocols. Mean effective dose of thyroid gland in brain scan group was calculated by TLD and ImPACT software which showed no significant difference (P < 0.001). Mean effective dose of thyroid gland in unidirectional and bi-directional sinus scan by TLD and ImPACT software were different significantly (P < 0.001). Also, the differences between CTDI values shown by brain and sinus scan protocol with semiconductor detector and those CTDI were significant (P < 0.001). The calculated values of absorbed dose and effective doses of thyroid by TLD and ImPACT software were not significantly different. Mean effective dose calculated for thyroid gland in head scans by TLD and ImPACT was less than the annual permissive level for thyroid gland suggested by International Committee on Radiological Protection. In this study, calculated values of thyroid effective dose in brain scan with 64-slice scanner were less than the calculated values in a similar study. Wolters Kluwer - Medknow 2019-08-29 /pmc/articles/PMC6743239/ /pubmed/31544059 http://dx.doi.org/10.4103/jmss.JMSS_40_18 Text en Copyright: © 2019 Journal of Medical Signals & Sensors http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Short Communication
Maziar, Asghar
Paydar, Reza
Azadbakht, Ghazal
Shahbazi-Gahrouei, Daryoush
Estimation of Absorbed Dose of the Thyroid Gland in Patients Undergoing 64-Slice Head Computed Tomography and Comparison the Results with ImPACT Software and Computed Tomography Scan Dose Index
title Estimation of Absorbed Dose of the Thyroid Gland in Patients Undergoing 64-Slice Head Computed Tomography and Comparison the Results with ImPACT Software and Computed Tomography Scan Dose Index
title_full Estimation of Absorbed Dose of the Thyroid Gland in Patients Undergoing 64-Slice Head Computed Tomography and Comparison the Results with ImPACT Software and Computed Tomography Scan Dose Index
title_fullStr Estimation of Absorbed Dose of the Thyroid Gland in Patients Undergoing 64-Slice Head Computed Tomography and Comparison the Results with ImPACT Software and Computed Tomography Scan Dose Index
title_full_unstemmed Estimation of Absorbed Dose of the Thyroid Gland in Patients Undergoing 64-Slice Head Computed Tomography and Comparison the Results with ImPACT Software and Computed Tomography Scan Dose Index
title_short Estimation of Absorbed Dose of the Thyroid Gland in Patients Undergoing 64-Slice Head Computed Tomography and Comparison the Results with ImPACT Software and Computed Tomography Scan Dose Index
title_sort estimation of absorbed dose of the thyroid gland in patients undergoing 64-slice head computed tomography and comparison the results with impact software and computed tomography scan dose index
topic Short Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6743239/
https://www.ncbi.nlm.nih.gov/pubmed/31544059
http://dx.doi.org/10.4103/jmss.JMSS_40_18
work_keys_str_mv AT maziarasghar estimationofabsorbeddoseofthethyroidglandinpatientsundergoing64sliceheadcomputedtomographyandcomparisontheresultswithimpactsoftwareandcomputedtomographyscandoseindex
AT paydarreza estimationofabsorbeddoseofthethyroidglandinpatientsundergoing64sliceheadcomputedtomographyandcomparisontheresultswithimpactsoftwareandcomputedtomographyscandoseindex
AT azadbakhtghazal estimationofabsorbeddoseofthethyroidglandinpatientsundergoing64sliceheadcomputedtomographyandcomparisontheresultswithimpactsoftwareandcomputedtomographyscandoseindex
AT shahbazigahroueidaryoush estimationofabsorbeddoseofthethyroidglandinpatientsundergoing64sliceheadcomputedtomographyandcomparisontheresultswithimpactsoftwareandcomputedtomographyscandoseindex