Cargando…
Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams
Gafchromic films are utilized for two-dimensional dose distribution measurements, especially in radiotherapy. In this study, we investigated a close connection between energy and dose rate of Gafchromic EBT3 films irradiating with 6 MV and Co-60 photon beams over a broad dose range. EBT3 films were...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6743241/ https://www.ncbi.nlm.nih.gov/pubmed/31544061 http://dx.doi.org/10.4103/jmss.JMSS_45_18 |
_version_ | 1783451247536242688 |
---|---|
author | Ataei, Gholamreza Rezaei, Maral Gorji, Kourosh Ebrahimnejad Banaei, Amin Goushbolagh, Nouraddin Abdi Farhood, Bagher Bagheri, Mahmoud Firouzjah, Razzagh Abedi |
author_facet | Ataei, Gholamreza Rezaei, Maral Gorji, Kourosh Ebrahimnejad Banaei, Amin Goushbolagh, Nouraddin Abdi Farhood, Bagher Bagheri, Mahmoud Firouzjah, Razzagh Abedi |
author_sort | Ataei, Gholamreza |
collection | PubMed |
description | Gafchromic films are utilized for two-dimensional dose distribution measurements, especially in radiotherapy. In this study, we investigated a close connection between energy and dose rate of Gafchromic EBT3 films irradiating with 6 MV and Co-60 photon beams over a broad dose range. EBT3 films were exposed to 6 MV and Co-60 photon beams using 4 and 2 Gy/min dose rates over a 10–400 cGy dose range. The films were scanned in red, green, and blue channels to obtain the optical density (OD)–dose curves. The OD–dose curves resulted from three-color scans for different photon energies and dose rates were compared by statistical independent t-test. For the radiations of Co-60 and 6 MV photon beams, the highest correlation was obtained between the 2 and 4 Gy/min dose rates with red and green channels, respectively. Moreover, the red channel had a greater OD response per dose value, following the green and blue channels. There was no significant difference between different photon energies’ (Co-60 and 6 MV) and dose rates’ (2 and 4 Gy/min) dependence on OD-dose response of EBT3 films over a broad domain of radiation dose, except for different photon energies in the blue channel. Our results revealed that the OD-dose response of EBT3 films is independent on photon energies (Co-60 and 6 MV) and dose rate (2 and 4 Gy/min) in the evaluated dose range (10–400 cGy). Therefore, the EBT3 films are suitable, consistent, and reliable instruments for dose measurements in radiotherapy. |
format | Online Article Text |
id | pubmed-6743241 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-67432412019-09-20 Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams Ataei, Gholamreza Rezaei, Maral Gorji, Kourosh Ebrahimnejad Banaei, Amin Goushbolagh, Nouraddin Abdi Farhood, Bagher Bagheri, Mahmoud Firouzjah, Razzagh Abedi J Med Signals Sens Short Communication Gafchromic films are utilized for two-dimensional dose distribution measurements, especially in radiotherapy. In this study, we investigated a close connection between energy and dose rate of Gafchromic EBT3 films irradiating with 6 MV and Co-60 photon beams over a broad dose range. EBT3 films were exposed to 6 MV and Co-60 photon beams using 4 and 2 Gy/min dose rates over a 10–400 cGy dose range. The films were scanned in red, green, and blue channels to obtain the optical density (OD)–dose curves. The OD–dose curves resulted from three-color scans for different photon energies and dose rates were compared by statistical independent t-test. For the radiations of Co-60 and 6 MV photon beams, the highest correlation was obtained between the 2 and 4 Gy/min dose rates with red and green channels, respectively. Moreover, the red channel had a greater OD response per dose value, following the green and blue channels. There was no significant difference between different photon energies’ (Co-60 and 6 MV) and dose rates’ (2 and 4 Gy/min) dependence on OD-dose response of EBT3 films over a broad domain of radiation dose, except for different photon energies in the blue channel. Our results revealed that the OD-dose response of EBT3 films is independent on photon energies (Co-60 and 6 MV) and dose rate (2 and 4 Gy/min) in the evaluated dose range (10–400 cGy). Therefore, the EBT3 films are suitable, consistent, and reliable instruments for dose measurements in radiotherapy. Wolters Kluwer - Medknow 2019-08-29 /pmc/articles/PMC6743241/ /pubmed/31544061 http://dx.doi.org/10.4103/jmss.JMSS_45_18 Text en Copyright: © 2019 Journal of Medical Signals & Sensors http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Short Communication Ataei, Gholamreza Rezaei, Maral Gorji, Kourosh Ebrahimnejad Banaei, Amin Goushbolagh, Nouraddin Abdi Farhood, Bagher Bagheri, Mahmoud Firouzjah, Razzagh Abedi Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams |
title | Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams |
title_full | Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams |
title_fullStr | Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams |
title_full_unstemmed | Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams |
title_short | Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams |
title_sort | evaluation of dose rate and photon energy dependence of gafchromic ebt3 film irradiating with 6 mv and co-60 photon beams |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6743241/ https://www.ncbi.nlm.nih.gov/pubmed/31544061 http://dx.doi.org/10.4103/jmss.JMSS_45_18 |
work_keys_str_mv | AT ataeigholamreza evaluationofdoserateandphotonenergydependenceofgafchromicebt3filmirradiatingwith6mvandco60photonbeams AT rezaeimaral evaluationofdoserateandphotonenergydependenceofgafchromicebt3filmirradiatingwith6mvandco60photonbeams AT gorjikouroshebrahimnejad evaluationofdoserateandphotonenergydependenceofgafchromicebt3filmirradiatingwith6mvandco60photonbeams AT banaeiamin evaluationofdoserateandphotonenergydependenceofgafchromicebt3filmirradiatingwith6mvandco60photonbeams AT goushbolaghnouraddinabdi evaluationofdoserateandphotonenergydependenceofgafchromicebt3filmirradiatingwith6mvandco60photonbeams AT farhoodbagher evaluationofdoserateandphotonenergydependenceofgafchromicebt3filmirradiatingwith6mvandco60photonbeams AT bagherimahmoud evaluationofdoserateandphotonenergydependenceofgafchromicebt3filmirradiatingwith6mvandco60photonbeams AT firouzjahrazzaghabedi evaluationofdoserateandphotonenergydependenceofgafchromicebt3filmirradiatingwith6mvandco60photonbeams |