Cargando…

Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams

Gafchromic films are utilized for two-dimensional dose distribution measurements, especially in radiotherapy. In this study, we investigated a close connection between energy and dose rate of Gafchromic EBT3 films irradiating with 6 MV and Co-60 photon beams over a broad dose range. EBT3 films were...

Descripción completa

Detalles Bibliográficos
Autores principales: Ataei, Gholamreza, Rezaei, Maral, Gorji, Kourosh Ebrahimnejad, Banaei, Amin, Goushbolagh, Nouraddin Abdi, Farhood, Bagher, Bagheri, Mahmoud, Firouzjah, Razzagh Abedi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6743241/
https://www.ncbi.nlm.nih.gov/pubmed/31544061
http://dx.doi.org/10.4103/jmss.JMSS_45_18
_version_ 1783451247536242688
author Ataei, Gholamreza
Rezaei, Maral
Gorji, Kourosh Ebrahimnejad
Banaei, Amin
Goushbolagh, Nouraddin Abdi
Farhood, Bagher
Bagheri, Mahmoud
Firouzjah, Razzagh Abedi
author_facet Ataei, Gholamreza
Rezaei, Maral
Gorji, Kourosh Ebrahimnejad
Banaei, Amin
Goushbolagh, Nouraddin Abdi
Farhood, Bagher
Bagheri, Mahmoud
Firouzjah, Razzagh Abedi
author_sort Ataei, Gholamreza
collection PubMed
description Gafchromic films are utilized for two-dimensional dose distribution measurements, especially in radiotherapy. In this study, we investigated a close connection between energy and dose rate of Gafchromic EBT3 films irradiating with 6 MV and Co-60 photon beams over a broad dose range. EBT3 films were exposed to 6 MV and Co-60 photon beams using 4 and 2 Gy/min dose rates over a 10–400 cGy dose range. The films were scanned in red, green, and blue channels to obtain the optical density (OD)–dose curves. The OD–dose curves resulted from three-color scans for different photon energies and dose rates were compared by statistical independent t-test. For the radiations of Co-60 and 6 MV photon beams, the highest correlation was obtained between the 2 and 4 Gy/min dose rates with red and green channels, respectively. Moreover, the red channel had a greater OD response per dose value, following the green and blue channels. There was no significant difference between different photon energies’ (Co-60 and 6 MV) and dose rates’ (2 and 4 Gy/min) dependence on OD-dose response of EBT3 films over a broad domain of radiation dose, except for different photon energies in the blue channel. Our results revealed that the OD-dose response of EBT3 films is independent on photon energies (Co-60 and 6 MV) and dose rate (2 and 4 Gy/min) in the evaluated dose range (10–400 cGy). Therefore, the EBT3 films are suitable, consistent, and reliable instruments for dose measurements in radiotherapy.
format Online
Article
Text
id pubmed-6743241
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-67432412019-09-20 Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams Ataei, Gholamreza Rezaei, Maral Gorji, Kourosh Ebrahimnejad Banaei, Amin Goushbolagh, Nouraddin Abdi Farhood, Bagher Bagheri, Mahmoud Firouzjah, Razzagh Abedi J Med Signals Sens Short Communication Gafchromic films are utilized for two-dimensional dose distribution measurements, especially in radiotherapy. In this study, we investigated a close connection between energy and dose rate of Gafchromic EBT3 films irradiating with 6 MV and Co-60 photon beams over a broad dose range. EBT3 films were exposed to 6 MV and Co-60 photon beams using 4 and 2 Gy/min dose rates over a 10–400 cGy dose range. The films were scanned in red, green, and blue channels to obtain the optical density (OD)–dose curves. The OD–dose curves resulted from three-color scans for different photon energies and dose rates were compared by statistical independent t-test. For the radiations of Co-60 and 6 MV photon beams, the highest correlation was obtained between the 2 and 4 Gy/min dose rates with red and green channels, respectively. Moreover, the red channel had a greater OD response per dose value, following the green and blue channels. There was no significant difference between different photon energies’ (Co-60 and 6 MV) and dose rates’ (2 and 4 Gy/min) dependence on OD-dose response of EBT3 films over a broad domain of radiation dose, except for different photon energies in the blue channel. Our results revealed that the OD-dose response of EBT3 films is independent on photon energies (Co-60 and 6 MV) and dose rate (2 and 4 Gy/min) in the evaluated dose range (10–400 cGy). Therefore, the EBT3 films are suitable, consistent, and reliable instruments for dose measurements in radiotherapy. Wolters Kluwer - Medknow 2019-08-29 /pmc/articles/PMC6743241/ /pubmed/31544061 http://dx.doi.org/10.4103/jmss.JMSS_45_18 Text en Copyright: © 2019 Journal of Medical Signals & Sensors http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Short Communication
Ataei, Gholamreza
Rezaei, Maral
Gorji, Kourosh Ebrahimnejad
Banaei, Amin
Goushbolagh, Nouraddin Abdi
Farhood, Bagher
Bagheri, Mahmoud
Firouzjah, Razzagh Abedi
Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams
title Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams
title_full Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams
title_fullStr Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams
title_full_unstemmed Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams
title_short Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams
title_sort evaluation of dose rate and photon energy dependence of gafchromic ebt3 film irradiating with 6 mv and co-60 photon beams
topic Short Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6743241/
https://www.ncbi.nlm.nih.gov/pubmed/31544061
http://dx.doi.org/10.4103/jmss.JMSS_45_18
work_keys_str_mv AT ataeigholamreza evaluationofdoserateandphotonenergydependenceofgafchromicebt3filmirradiatingwith6mvandco60photonbeams
AT rezaeimaral evaluationofdoserateandphotonenergydependenceofgafchromicebt3filmirradiatingwith6mvandco60photonbeams
AT gorjikouroshebrahimnejad evaluationofdoserateandphotonenergydependenceofgafchromicebt3filmirradiatingwith6mvandco60photonbeams
AT banaeiamin evaluationofdoserateandphotonenergydependenceofgafchromicebt3filmirradiatingwith6mvandco60photonbeams
AT goushbolaghnouraddinabdi evaluationofdoserateandphotonenergydependenceofgafchromicebt3filmirradiatingwith6mvandco60photonbeams
AT farhoodbagher evaluationofdoserateandphotonenergydependenceofgafchromicebt3filmirradiatingwith6mvandco60photonbeams
AT bagherimahmoud evaluationofdoserateandphotonenergydependenceofgafchromicebt3filmirradiatingwith6mvandco60photonbeams
AT firouzjahrazzaghabedi evaluationofdoserateandphotonenergydependenceofgafchromicebt3filmirradiatingwith6mvandco60photonbeams