Cargando…
A Good Practice–Compliant Clinical Trial Imaging Management System for Multicenter Clinical Trials: Development and Validation Study
BACKGROUND: With the rapid increase in utilization of imaging endpoints in multicenter clinical trials, the amount of data and workflow complexity have also increased. A Clinical Trial Imaging Management System (CTIMS) is required to comprehensively support imaging processes in clinical trials. The...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
JMIR Publications
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6743263/ https://www.ncbi.nlm.nih.gov/pubmed/31471962 http://dx.doi.org/10.2196/14310 |
_version_ | 1783451252062945280 |
---|---|
author | Shin, Youngbin Kim, Kyung Won Lee, Amy Junghyun Sung, Yu Sub Ahn, Suah Koo, Ja Hwan Choi, Chang Gyu Ko, Yousun Kim, Ho Sung Park, Seong Ho |
author_facet | Shin, Youngbin Kim, Kyung Won Lee, Amy Junghyun Sung, Yu Sub Ahn, Suah Koo, Ja Hwan Choi, Chang Gyu Ko, Yousun Kim, Ho Sung Park, Seong Ho |
author_sort | Shin, Youngbin |
collection | PubMed |
description | BACKGROUND: With the rapid increase in utilization of imaging endpoints in multicenter clinical trials, the amount of data and workflow complexity have also increased. A Clinical Trial Imaging Management System (CTIMS) is required to comprehensively support imaging processes in clinical trials. The US Food and Drug Administration (FDA) issued a guidance protocol in 2018 for appropriate use of medical imaging in accordance with many regulations including the Good Clinical Practice (GCP) guidelines. Existing research on CTIMS, however, has mainly focused on functions and structures of systems rather than regulation and compliance. OBJECTIVE: We aimed to develop a comprehensive CTIMS to meet the current regulatory guidelines and various required functions. We also aimed to perform computerized system validation focusing on the regulatory compliance of our CTIMS. METHODS: Key regulatory requirements of CTIMS were extracted thorough review of many related regulations and guidelines including International Conference on Harmonization-GCP E6, FDA 21 Code of Federal Regulations parts 11 and 820, Good Automated Manufacturing Practice, and Clinical Data Interchange Standards Consortium. The system architecture was designed in accordance with these regulations by a multidisciplinary team including radiologists, engineers, clinical trial specialists, and regulatory medicine professionals. Computerized system validation of the developed CTIMS was performed internally and externally. RESULTS: Our CTIMS (AiCRO) was developed based on a two-layer design composed of the server system and the client system, which is efficient at meeting the regulatory and functional requirements. The server system manages system security, data archive, backup, and audit trail. The client system provides various functions including deidentification, image transfer, image viewer, image quality control, and electronic record. Computerized system validation was performed internally using a V-model and externally by a global quality assurance company to demonstrate that AiCRO meets all regulatory and functional requirements. CONCLUSIONS: We developed a Good Practice–compliant CTIMS—AiCRO system—to manage large amounts of image data and complexity of imaging management processes in clinical trials. Our CTIMS adopts and adheres to all regulatory and functional requirements and has been thoroughly validated. |
format | Online Article Text |
id | pubmed-6743263 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | JMIR Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-67432632019-09-23 A Good Practice–Compliant Clinical Trial Imaging Management System for Multicenter Clinical Trials: Development and Validation Study Shin, Youngbin Kim, Kyung Won Lee, Amy Junghyun Sung, Yu Sub Ahn, Suah Koo, Ja Hwan Choi, Chang Gyu Ko, Yousun Kim, Ho Sung Park, Seong Ho JMIR Med Inform Original Paper BACKGROUND: With the rapid increase in utilization of imaging endpoints in multicenter clinical trials, the amount of data and workflow complexity have also increased. A Clinical Trial Imaging Management System (CTIMS) is required to comprehensively support imaging processes in clinical trials. The US Food and Drug Administration (FDA) issued a guidance protocol in 2018 for appropriate use of medical imaging in accordance with many regulations including the Good Clinical Practice (GCP) guidelines. Existing research on CTIMS, however, has mainly focused on functions and structures of systems rather than regulation and compliance. OBJECTIVE: We aimed to develop a comprehensive CTIMS to meet the current regulatory guidelines and various required functions. We also aimed to perform computerized system validation focusing on the regulatory compliance of our CTIMS. METHODS: Key regulatory requirements of CTIMS were extracted thorough review of many related regulations and guidelines including International Conference on Harmonization-GCP E6, FDA 21 Code of Federal Regulations parts 11 and 820, Good Automated Manufacturing Practice, and Clinical Data Interchange Standards Consortium. The system architecture was designed in accordance with these regulations by a multidisciplinary team including radiologists, engineers, clinical trial specialists, and regulatory medicine professionals. Computerized system validation of the developed CTIMS was performed internally and externally. RESULTS: Our CTIMS (AiCRO) was developed based on a two-layer design composed of the server system and the client system, which is efficient at meeting the regulatory and functional requirements. The server system manages system security, data archive, backup, and audit trail. The client system provides various functions including deidentification, image transfer, image viewer, image quality control, and electronic record. Computerized system validation was performed internally using a V-model and externally by a global quality assurance company to demonstrate that AiCRO meets all regulatory and functional requirements. CONCLUSIONS: We developed a Good Practice–compliant CTIMS—AiCRO system—to manage large amounts of image data and complexity of imaging management processes in clinical trials. Our CTIMS adopts and adheres to all regulatory and functional requirements and has been thoroughly validated. JMIR Publications 2019-08-30 /pmc/articles/PMC6743263/ /pubmed/31471962 http://dx.doi.org/10.2196/14310 Text en ©Youngbin Shin, Kyung Won Kim, Amy Junghyun Lee, Yu Sub Sung, Suah Ahn, Ja Hwan Koo, Chang Gyu Choi, Yousun Ko, Ho Sung Kim, Seong Ho Park. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 30.08.2019. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Medical Informatics, is properly cited. The complete bibliographic information, a link to the original publication on http://medinform.jmir.org/, as well as this copyright and license information must be included. |
spellingShingle | Original Paper Shin, Youngbin Kim, Kyung Won Lee, Amy Junghyun Sung, Yu Sub Ahn, Suah Koo, Ja Hwan Choi, Chang Gyu Ko, Yousun Kim, Ho Sung Park, Seong Ho A Good Practice–Compliant Clinical Trial Imaging Management System for Multicenter Clinical Trials: Development and Validation Study |
title | A Good Practice–Compliant Clinical Trial Imaging Management System for Multicenter Clinical Trials: Development and Validation Study |
title_full | A Good Practice–Compliant Clinical Trial Imaging Management System for Multicenter Clinical Trials: Development and Validation Study |
title_fullStr | A Good Practice–Compliant Clinical Trial Imaging Management System for Multicenter Clinical Trials: Development and Validation Study |
title_full_unstemmed | A Good Practice–Compliant Clinical Trial Imaging Management System for Multicenter Clinical Trials: Development and Validation Study |
title_short | A Good Practice–Compliant Clinical Trial Imaging Management System for Multicenter Clinical Trials: Development and Validation Study |
title_sort | good practice–compliant clinical trial imaging management system for multicenter clinical trials: development and validation study |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6743263/ https://www.ncbi.nlm.nih.gov/pubmed/31471962 http://dx.doi.org/10.2196/14310 |
work_keys_str_mv | AT shinyoungbin agoodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT kimkyungwon agoodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT leeamyjunghyun agoodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT sungyusub agoodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT ahnsuah agoodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT koojahwan agoodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT choichanggyu agoodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT koyousun agoodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT kimhosung agoodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT parkseongho agoodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT shinyoungbin goodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT kimkyungwon goodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT leeamyjunghyun goodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT sungyusub goodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT ahnsuah goodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT koojahwan goodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT choichanggyu goodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT koyousun goodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT kimhosung goodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy AT parkseongho goodpracticecompliantclinicaltrialimagingmanagementsystemformulticenterclinicaltrialsdevelopmentandvalidationstudy |