Cargando…

Determination of reliable lung function parameters in intubated mice

BACKGROUND: Animal models and, in particular, mice models, are important tools to investigate the pathogenesis of respiratory diseases and to test potential new therapeutic drugs. Lung function measurement is a key step in such investigation. In mice, it is usually performed using forced oscillation...

Descripción completa

Detalles Bibliográficos
Autores principales: Bonnardel, Eline, Prevel, Renaud, Campagnac, Marilyne, Dubreuil, Marielle, Marthan, Roger, Berger, Patrick, Dupin, Isabelle
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6744631/
https://www.ncbi.nlm.nih.gov/pubmed/31521163
http://dx.doi.org/10.1186/s12931-019-1177-9
Descripción
Sumario:BACKGROUND: Animal models and, in particular, mice models, are important tools to investigate the pathogenesis of respiratory diseases and to test potential new therapeutic drugs. Lung function measurement is a key step in such investigation. In mice, it is usually performed using forced oscillation technique (FOT), negative pressure-driven forced expiratory (NPFE) and pressure-volume (PV) curve maneuvers. However, these techniques require a tracheostomy, which therefore only allows end-point measurements. Orotracheal intubation has been reported to be feasible and to give reproducible lung function measurements, but the agreement between intubation and tracheostomy generated-data remains to be tested. METHODS: Using the Flexivent system, we measured lung function parameters (in particular, forced vital capacity (FVC), forced expiratory volume in the first 0.1 s (FEV0.1), compliance (Crs) of the respiratory system, compliance (C) measured using PV loop and an estimate of inspiratory capacity (A)) in healthy intubated BALB/cJ mice and C57BL/6 J mice and compared the results with similar measurements performed in the same mice subsequently tracheostomized after intubation, by means of paired comparison method, correlation and Bland-Altman analysis. The feasibility of repetitive lung function measurements by intubation was also tested. RESULTS: We identified parameters that are accurately evaluated in intubated animals (i.e., FVC, FEV0.1, Crs, C and A in BALB/cJ and FVC, FEV0.1, and A in C57BL/6 J). Repetitive lung function measurements were obtained in C57BL/6 J mice. CONCLUSION: This subset of lung function parameters in orotracheally intubated mice is reliable, thereby allowing relevant longitudinal studies. SUPPLEMENTARY INFORMATION: Supplementary information accompanies this paper at (10.1186/s12931-019-1177-9).