Cargando…
Accuracy of Colon Capsule Endoscopy for Colorectal Neoplasia Detection in Individuals Referred for a Screening Colonoscopy
BACKROUND: Capsule colonoscopy might present an alternative to colonoscopy for colorectal neoplasia screening. AIM: To assess the accuracy of second-generation capsule colonoscopy (CCE2) for colorectal neoplasia detection compared with conventional colonoscopy (CC). METHODS: From 2011–2015, we perfo...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6745144/ https://www.ncbi.nlm.nih.gov/pubmed/31565052 http://dx.doi.org/10.1155/2019/5975438 |
_version_ | 1783451495146979328 |
---|---|
author | Voska, Michal Zavoral, Miroslav Grega, Tomas Majek, Ondrej Martinek, Jan Tacheci, Ilja Benes, Marek Vojtechova, Gabriela Drastich, Pavel Bures, Jan Spicak, Julius Buckova, Barbora Ngo, Ondrej Suchanek, Stepan |
author_facet | Voska, Michal Zavoral, Miroslav Grega, Tomas Majek, Ondrej Martinek, Jan Tacheci, Ilja Benes, Marek Vojtechova, Gabriela Drastich, Pavel Bures, Jan Spicak, Julius Buckova, Barbora Ngo, Ondrej Suchanek, Stepan |
author_sort | Voska, Michal |
collection | PubMed |
description | BACKROUND: Capsule colonoscopy might present an alternative to colonoscopy for colorectal neoplasia screening. AIM: To assess the accuracy of second-generation capsule colonoscopy (CCE2) for colorectal neoplasia detection compared with conventional colonoscopy (CC). METHODS: From 2011–2015, we performed a multicenter, prospective, cross-over study evaluating the use of CCE2 as a possible colorectal cancer (CRC) screening test based on the assessment of the method's characteristics (accuracy) and safety and patient acceptance of the routine. Enrolled participants fulfilled the CRC screening population criteria if they were asymptomatic, were older than 50, and had no personal or familial history of colorectal neoplasia. The primary outcome was accuracy for the detection of polyps ≥ 6 mm. Secondary outcomes were accuracy for all polyps, polyps ≥ 10 mm, adenomas ≥ 10 mm, and cancers, the quality of bowel cleansing, safety, and CCE2 acceptability by the screening population. RESULTS: A total of 236 individuals were examined; 11 patients (5%) were excluded. Therefore, 225 subjects (95%) were considered in the intention-to-screen (ITS) group. A total of 201 patients (89%) completed both examinations successfully (per protocol group). In the ITS group, polyps were diagnosed during CC in 114 subjects (51%); polyps ≥ 6 mm, polyps ≥ 10 mm, and adenomas ≥ 10 mm were diagnosed in 34 (15%), 16 (7%), and 11 (5%) patients, respectively. The sensitivity of CCE2 for polyps ≥ 6 mm, polyps ≥ 10 mm, and adenomas ≥ 10 mm was 79% (95% confidence interval (CI): 62–91%), 88% (95% CI: 62–98%), and 100% (95% CI: 72–100%), respectively. CONCLUSION: Second-generation capsule colonoscopy is a safe, noninvasive, and sensitive method for colorectal neoplasia detection although CC remains the preferred method for considerable proportion of subjects. CCE2 may therefore be accepted as the primary screening test for colorectal cancer screening. |
format | Online Article Text |
id | pubmed-6745144 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-67451442019-09-29 Accuracy of Colon Capsule Endoscopy for Colorectal Neoplasia Detection in Individuals Referred for a Screening Colonoscopy Voska, Michal Zavoral, Miroslav Grega, Tomas Majek, Ondrej Martinek, Jan Tacheci, Ilja Benes, Marek Vojtechova, Gabriela Drastich, Pavel Bures, Jan Spicak, Julius Buckova, Barbora Ngo, Ondrej Suchanek, Stepan Gastroenterol Res Pract Research Article BACKROUND: Capsule colonoscopy might present an alternative to colonoscopy for colorectal neoplasia screening. AIM: To assess the accuracy of second-generation capsule colonoscopy (CCE2) for colorectal neoplasia detection compared with conventional colonoscopy (CC). METHODS: From 2011–2015, we performed a multicenter, prospective, cross-over study evaluating the use of CCE2 as a possible colorectal cancer (CRC) screening test based on the assessment of the method's characteristics (accuracy) and safety and patient acceptance of the routine. Enrolled participants fulfilled the CRC screening population criteria if they were asymptomatic, were older than 50, and had no personal or familial history of colorectal neoplasia. The primary outcome was accuracy for the detection of polyps ≥ 6 mm. Secondary outcomes were accuracy for all polyps, polyps ≥ 10 mm, adenomas ≥ 10 mm, and cancers, the quality of bowel cleansing, safety, and CCE2 acceptability by the screening population. RESULTS: A total of 236 individuals were examined; 11 patients (5%) were excluded. Therefore, 225 subjects (95%) were considered in the intention-to-screen (ITS) group. A total of 201 patients (89%) completed both examinations successfully (per protocol group). In the ITS group, polyps were diagnosed during CC in 114 subjects (51%); polyps ≥ 6 mm, polyps ≥ 10 mm, and adenomas ≥ 10 mm were diagnosed in 34 (15%), 16 (7%), and 11 (5%) patients, respectively. The sensitivity of CCE2 for polyps ≥ 6 mm, polyps ≥ 10 mm, and adenomas ≥ 10 mm was 79% (95% confidence interval (CI): 62–91%), 88% (95% CI: 62–98%), and 100% (95% CI: 72–100%), respectively. CONCLUSION: Second-generation capsule colonoscopy is a safe, noninvasive, and sensitive method for colorectal neoplasia detection although CC remains the preferred method for considerable proportion of subjects. CCE2 may therefore be accepted as the primary screening test for colorectal cancer screening. Hindawi 2019-09-03 /pmc/articles/PMC6745144/ /pubmed/31565052 http://dx.doi.org/10.1155/2019/5975438 Text en Copyright © 2019 Michal Voska et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Voska, Michal Zavoral, Miroslav Grega, Tomas Majek, Ondrej Martinek, Jan Tacheci, Ilja Benes, Marek Vojtechova, Gabriela Drastich, Pavel Bures, Jan Spicak, Julius Buckova, Barbora Ngo, Ondrej Suchanek, Stepan Accuracy of Colon Capsule Endoscopy for Colorectal Neoplasia Detection in Individuals Referred for a Screening Colonoscopy |
title | Accuracy of Colon Capsule Endoscopy for Colorectal Neoplasia Detection in Individuals Referred for a Screening Colonoscopy |
title_full | Accuracy of Colon Capsule Endoscopy for Colorectal Neoplasia Detection in Individuals Referred for a Screening Colonoscopy |
title_fullStr | Accuracy of Colon Capsule Endoscopy for Colorectal Neoplasia Detection in Individuals Referred for a Screening Colonoscopy |
title_full_unstemmed | Accuracy of Colon Capsule Endoscopy for Colorectal Neoplasia Detection in Individuals Referred for a Screening Colonoscopy |
title_short | Accuracy of Colon Capsule Endoscopy for Colorectal Neoplasia Detection in Individuals Referred for a Screening Colonoscopy |
title_sort | accuracy of colon capsule endoscopy for colorectal neoplasia detection in individuals referred for a screening colonoscopy |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6745144/ https://www.ncbi.nlm.nih.gov/pubmed/31565052 http://dx.doi.org/10.1155/2019/5975438 |
work_keys_str_mv | AT voskamichal accuracyofcoloncapsuleendoscopyforcolorectalneoplasiadetectioninindividualsreferredforascreeningcolonoscopy AT zavoralmiroslav accuracyofcoloncapsuleendoscopyforcolorectalneoplasiadetectioninindividualsreferredforascreeningcolonoscopy AT gregatomas accuracyofcoloncapsuleendoscopyforcolorectalneoplasiadetectioninindividualsreferredforascreeningcolonoscopy AT majekondrej accuracyofcoloncapsuleendoscopyforcolorectalneoplasiadetectioninindividualsreferredforascreeningcolonoscopy AT martinekjan accuracyofcoloncapsuleendoscopyforcolorectalneoplasiadetectioninindividualsreferredforascreeningcolonoscopy AT tacheciilja accuracyofcoloncapsuleendoscopyforcolorectalneoplasiadetectioninindividualsreferredforascreeningcolonoscopy AT benesmarek accuracyofcoloncapsuleendoscopyforcolorectalneoplasiadetectioninindividualsreferredforascreeningcolonoscopy AT vojtechovagabriela accuracyofcoloncapsuleendoscopyforcolorectalneoplasiadetectioninindividualsreferredforascreeningcolonoscopy AT drastichpavel accuracyofcoloncapsuleendoscopyforcolorectalneoplasiadetectioninindividualsreferredforascreeningcolonoscopy AT buresjan accuracyofcoloncapsuleendoscopyforcolorectalneoplasiadetectioninindividualsreferredforascreeningcolonoscopy AT spicakjulius accuracyofcoloncapsuleendoscopyforcolorectalneoplasiadetectioninindividualsreferredforascreeningcolonoscopy AT buckovabarbora accuracyofcoloncapsuleendoscopyforcolorectalneoplasiadetectioninindividualsreferredforascreeningcolonoscopy AT ngoondrej accuracyofcoloncapsuleendoscopyforcolorectalneoplasiadetectioninindividualsreferredforascreeningcolonoscopy AT suchanekstepan accuracyofcoloncapsuleendoscopyforcolorectalneoplasiadetectioninindividualsreferredforascreeningcolonoscopy |