Cargando…
Reduced periprosthetic fracture rate when changing from a tapered polished stem to an anatomical stem for cemented hip arthroplasty: an observational prospective cohort study with a follow-up of 2 years
Background and purpose — Straight collarless polished tapered stems have been linked to an increased risk for periprosthetic femur fractures in comparison with anatomically shaped stems, especially in elderly patients. Therefore, we evaluated the effect of an orthopedic department’s full transition...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Taylor & Francis
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6746294/ https://www.ncbi.nlm.nih.gov/pubmed/31154885 http://dx.doi.org/10.1080/17453674.2019.1624339 |
_version_ | 1783451685701550080 |
---|---|
author | Mohammed, Jabbar Mukka, Sebastian Hedbeck, Carl-Johan Chammout, Ghazi Gordon, Max Sköldenberg, Olof |
author_facet | Mohammed, Jabbar Mukka, Sebastian Hedbeck, Carl-Johan Chammout, Ghazi Gordon, Max Sköldenberg, Olof |
author_sort | Mohammed, Jabbar |
collection | PubMed |
description | Background and purpose — Straight collarless polished tapered stems have been linked to an increased risk for periprosthetic femur fractures in comparison with anatomically shaped stems, especially in elderly patients. Therefore, we evaluated the effect of an orthopedic department’s full transition from the use of a cemented collarless, polished, tapered stem to a cemented anatomic stem on the cumulative incidence of postoperative periprosthetic fracture (PPF). Patients and methods — This prospective single-center cohort study comprises a consecutive series of 1,077 patients who underwent a cemented hip arthroplasty using either a collarless polished tapered stem (PTS group, n = 543) or an anatomic stem (AS group, n = 534). We assessed the incidence of PPF 2 years postoperatively and used a Cox regression model adjusted for age, sex, ASA class, cognitive impairment, BMI, diagnosis, and surgical approach for outcome analysis. Results — Mean age at primary surgery was 82 years (49–102), 73% of the patients were female, and 75% underwent surgery for a femoral neck fracture. The PPF rate was lowered from 3.3% (n = 18) in the PTS group to 0.4% (n = 2) in the AS group. The overall complication rate was also lowered from 8.8% in the PTS group to 4.5% in the AS group. In the regression model only cognitive dysfunction (HR 3.8, 95% CI 1.4–10) and the type of stem (PTS vs AS, HR 0.1, CI 0.0–0.5) were correlated with outcome. Interpretation — For elderly patients with poor bone quality use of cemented anatomic stems leads to a substantial reduction in periprosthetic fracture rate without increasing other complications. |
format | Online Article Text |
id | pubmed-6746294 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Taylor & Francis |
record_format | MEDLINE/PubMed |
spelling | pubmed-67462942019-10-01 Reduced periprosthetic fracture rate when changing from a tapered polished stem to an anatomical stem for cemented hip arthroplasty: an observational prospective cohort study with a follow-up of 2 years Mohammed, Jabbar Mukka, Sebastian Hedbeck, Carl-Johan Chammout, Ghazi Gordon, Max Sköldenberg, Olof Acta Orthop Article Background and purpose — Straight collarless polished tapered stems have been linked to an increased risk for periprosthetic femur fractures in comparison with anatomically shaped stems, especially in elderly patients. Therefore, we evaluated the effect of an orthopedic department’s full transition from the use of a cemented collarless, polished, tapered stem to a cemented anatomic stem on the cumulative incidence of postoperative periprosthetic fracture (PPF). Patients and methods — This prospective single-center cohort study comprises a consecutive series of 1,077 patients who underwent a cemented hip arthroplasty using either a collarless polished tapered stem (PTS group, n = 543) or an anatomic stem (AS group, n = 534). We assessed the incidence of PPF 2 years postoperatively and used a Cox regression model adjusted for age, sex, ASA class, cognitive impairment, BMI, diagnosis, and surgical approach for outcome analysis. Results — Mean age at primary surgery was 82 years (49–102), 73% of the patients were female, and 75% underwent surgery for a femoral neck fracture. The PPF rate was lowered from 3.3% (n = 18) in the PTS group to 0.4% (n = 2) in the AS group. The overall complication rate was also lowered from 8.8% in the PTS group to 4.5% in the AS group. In the regression model only cognitive dysfunction (HR 3.8, 95% CI 1.4–10) and the type of stem (PTS vs AS, HR 0.1, CI 0.0–0.5) were correlated with outcome. Interpretation — For elderly patients with poor bone quality use of cemented anatomic stems leads to a substantial reduction in periprosthetic fracture rate without increasing other complications. Taylor & Francis 2019-10 2019-06-03 /pmc/articles/PMC6746294/ /pubmed/31154885 http://dx.doi.org/10.1080/17453674.2019.1624339 Text en © 2019 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Article Mohammed, Jabbar Mukka, Sebastian Hedbeck, Carl-Johan Chammout, Ghazi Gordon, Max Sköldenberg, Olof Reduced periprosthetic fracture rate when changing from a tapered polished stem to an anatomical stem for cemented hip arthroplasty: an observational prospective cohort study with a follow-up of 2 years |
title | Reduced periprosthetic fracture rate when changing from a tapered polished stem to an anatomical stem for cemented hip arthroplasty: an observational prospective cohort study with a follow-up of 2 years |
title_full | Reduced periprosthetic fracture rate when changing from a tapered polished stem to an anatomical stem for cemented hip arthroplasty: an observational prospective cohort study with a follow-up of 2 years |
title_fullStr | Reduced periprosthetic fracture rate when changing from a tapered polished stem to an anatomical stem for cemented hip arthroplasty: an observational prospective cohort study with a follow-up of 2 years |
title_full_unstemmed | Reduced periprosthetic fracture rate when changing from a tapered polished stem to an anatomical stem for cemented hip arthroplasty: an observational prospective cohort study with a follow-up of 2 years |
title_short | Reduced periprosthetic fracture rate when changing from a tapered polished stem to an anatomical stem for cemented hip arthroplasty: an observational prospective cohort study with a follow-up of 2 years |
title_sort | reduced periprosthetic fracture rate when changing from a tapered polished stem to an anatomical stem for cemented hip arthroplasty: an observational prospective cohort study with a follow-up of 2 years |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6746294/ https://www.ncbi.nlm.nih.gov/pubmed/31154885 http://dx.doi.org/10.1080/17453674.2019.1624339 |
work_keys_str_mv | AT mohammedjabbar reducedperiprostheticfractureratewhenchangingfromataperedpolishedstemtoananatomicalstemforcementedhiparthroplastyanobservationalprospectivecohortstudywithafollowupof2years AT mukkasebastian reducedperiprostheticfractureratewhenchangingfromataperedpolishedstemtoananatomicalstemforcementedhiparthroplastyanobservationalprospectivecohortstudywithafollowupof2years AT hedbeckcarljohan reducedperiprostheticfractureratewhenchangingfromataperedpolishedstemtoananatomicalstemforcementedhiparthroplastyanobservationalprospectivecohortstudywithafollowupof2years AT chammoutghazi reducedperiprostheticfractureratewhenchangingfromataperedpolishedstemtoananatomicalstemforcementedhiparthroplastyanobservationalprospectivecohortstudywithafollowupof2years AT gordonmax reducedperiprostheticfractureratewhenchangingfromataperedpolishedstemtoananatomicalstemforcementedhiparthroplastyanobservationalprospectivecohortstudywithafollowupof2years AT skoldenbergolof reducedperiprostheticfractureratewhenchangingfromataperedpolishedstemtoananatomicalstemforcementedhiparthroplastyanobservationalprospectivecohortstudywithafollowupof2years |