Cargando…

Printed Flexible Microelectrode for Application of Nanosecond Pulsed Electric Fields on Cells

Medical treatment is increasingly benefiting from biomedical microsystems, especially the trending telemedical application. A promising modality for tumor therapy showed the application of nanosecond pulsed electric fields (nsPEF) on cells to achieve nanoporation, cell death, and other cell reaction...

Descripción completa

Detalles Bibliográficos
Autores principales: Schubert, Martin, Rasche, Jens, Laurila, Mika-Matti, Vuorinen, Tiina, Mäntysalo, Matti, Bock, Karlheinz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6747599/
https://www.ncbi.nlm.nih.gov/pubmed/31450575
http://dx.doi.org/10.3390/ma12172713
_version_ 1783451936181190656
author Schubert, Martin
Rasche, Jens
Laurila, Mika-Matti
Vuorinen, Tiina
Mäntysalo, Matti
Bock, Karlheinz
author_facet Schubert, Martin
Rasche, Jens
Laurila, Mika-Matti
Vuorinen, Tiina
Mäntysalo, Matti
Bock, Karlheinz
author_sort Schubert, Martin
collection PubMed
description Medical treatment is increasingly benefiting from biomedical microsystems, especially the trending telemedical application. A promising modality for tumor therapy showed the application of nanosecond pulsed electric fields (nsPEF) on cells to achieve nanoporation, cell death, and other cell reactions. A key technology for this method is the generation of pulsed fields in the nanosecond range with high-field strengths in the range of several kilovolts per centimeter. For further biomedical applications, state-of-the-art setups need to decrease in size and improve their capability of integration into microsystems. Due to demanding electronic requirements, i.e., using high voltages and fast pulses, miniaturization and low-cost fabrication of the electrode is first considered. This paper proposes a proof-of-concept for a miniaturized printed flexible electrode that can apply nsPEF on adherent fibroblast cells. The interdigital gold electrode was printed on polyimide with line-width of about 10 µm using an electrohydrodynamic inkjet printer. Furthermore, an electrical circuit was developed to generate both electrical pulses in the nano-second range and voltages up to 180 V. The electrode was integrated into an experimental setup for in-vitro application to human fibroblasts. Field strengths up to 100 kV/cm with 45 ns pulse duration were applied, depending on the degree of cell confluence. The cells show contraction, detachment from the electrode, and lethal reactions after the nsPEF treatment. Furthermore, this printed miniaturized electrode was found to be suitable for subsequent microsystem integration and further cell experiments to optimize pulse parameters for control of cell reaction and behavior.
format Online
Article
Text
id pubmed-6747599
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-67475992019-09-27 Printed Flexible Microelectrode for Application of Nanosecond Pulsed Electric Fields on Cells Schubert, Martin Rasche, Jens Laurila, Mika-Matti Vuorinen, Tiina Mäntysalo, Matti Bock, Karlheinz Materials (Basel) Article Medical treatment is increasingly benefiting from biomedical microsystems, especially the trending telemedical application. A promising modality for tumor therapy showed the application of nanosecond pulsed electric fields (nsPEF) on cells to achieve nanoporation, cell death, and other cell reactions. A key technology for this method is the generation of pulsed fields in the nanosecond range with high-field strengths in the range of several kilovolts per centimeter. For further biomedical applications, state-of-the-art setups need to decrease in size and improve their capability of integration into microsystems. Due to demanding electronic requirements, i.e., using high voltages and fast pulses, miniaturization and low-cost fabrication of the electrode is first considered. This paper proposes a proof-of-concept for a miniaturized printed flexible electrode that can apply nsPEF on adherent fibroblast cells. The interdigital gold electrode was printed on polyimide with line-width of about 10 µm using an electrohydrodynamic inkjet printer. Furthermore, an electrical circuit was developed to generate both electrical pulses in the nano-second range and voltages up to 180 V. The electrode was integrated into an experimental setup for in-vitro application to human fibroblasts. Field strengths up to 100 kV/cm with 45 ns pulse duration were applied, depending on the degree of cell confluence. The cells show contraction, detachment from the electrode, and lethal reactions after the nsPEF treatment. Furthermore, this printed miniaturized electrode was found to be suitable for subsequent microsystem integration and further cell experiments to optimize pulse parameters for control of cell reaction and behavior. MDPI 2019-08-24 /pmc/articles/PMC6747599/ /pubmed/31450575 http://dx.doi.org/10.3390/ma12172713 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Schubert, Martin
Rasche, Jens
Laurila, Mika-Matti
Vuorinen, Tiina
Mäntysalo, Matti
Bock, Karlheinz
Printed Flexible Microelectrode for Application of Nanosecond Pulsed Electric Fields on Cells
title Printed Flexible Microelectrode for Application of Nanosecond Pulsed Electric Fields on Cells
title_full Printed Flexible Microelectrode for Application of Nanosecond Pulsed Electric Fields on Cells
title_fullStr Printed Flexible Microelectrode for Application of Nanosecond Pulsed Electric Fields on Cells
title_full_unstemmed Printed Flexible Microelectrode for Application of Nanosecond Pulsed Electric Fields on Cells
title_short Printed Flexible Microelectrode for Application of Nanosecond Pulsed Electric Fields on Cells
title_sort printed flexible microelectrode for application of nanosecond pulsed electric fields on cells
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6747599/
https://www.ncbi.nlm.nih.gov/pubmed/31450575
http://dx.doi.org/10.3390/ma12172713
work_keys_str_mv AT schubertmartin printedflexiblemicroelectrodeforapplicationofnanosecondpulsedelectricfieldsoncells
AT raschejens printedflexiblemicroelectrodeforapplicationofnanosecondpulsedelectricfieldsoncells
AT laurilamikamatti printedflexiblemicroelectrodeforapplicationofnanosecondpulsedelectricfieldsoncells
AT vuorinentiina printedflexiblemicroelectrodeforapplicationofnanosecondpulsedelectricfieldsoncells
AT mantysalomatti printedflexiblemicroelectrodeforapplicationofnanosecondpulsedelectricfieldsoncells
AT bockkarlheinz printedflexiblemicroelectrodeforapplicationofnanosecondpulsedelectricfieldsoncells