Cargando…

Effect of 0.2% peracetic acid disinfection on the horizontal dimension of implant framework indexed with two autopolymerized acrylic resins

BACKGROUND: To minimize misfit between prosthesis and implant, the welding of the implant fixed partial denture (IFPD) framework is recommended and autopolymerized acrylic resin (AR) is the material of choice for the indexing process. As for any prosthetic device that comes into contact with saliva...

Descripción completa

Detalles Bibliográficos
Autores principales: da Fonseca, Emanuely Ronconi, Santana, Paula Pereira, Xible, Anuar Antonio, Curtis, Donald A., Kano, Stefania Carvalho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749003/
https://www.ncbi.nlm.nih.gov/pubmed/31531734
http://dx.doi.org/10.1186/s40729-019-0186-2
_version_ 1783452187072921600
author da Fonseca, Emanuely Ronconi
Santana, Paula Pereira
Xible, Anuar Antonio
Curtis, Donald A.
Kano, Stefania Carvalho
author_facet da Fonseca, Emanuely Ronconi
Santana, Paula Pereira
Xible, Anuar Antonio
Curtis, Donald A.
Kano, Stefania Carvalho
author_sort da Fonseca, Emanuely Ronconi
collection PubMed
description BACKGROUND: To minimize misfit between prosthesis and implant, the welding of the implant fixed partial denture (IFPD) framework is recommended and autopolymerized acrylic resin (AR) is the material of choice for the indexing process. As for any prosthetic device that comes into contact with saliva and blood in the oral cavity, IFPD indexed with AR must be disinfected before sending to the laboratory. However, disinfection procedures are often neglected for fear of shrinkage or distortion caused by a dimensional change of the acrylic resin. Peracetic acid is a high-level disinfectant agent at low concentrations and immersion time, with no reported toxic residues, and it is not inactivated in the presence of organic matter when compared to other disinfectants. This study aimed to evaluate the influence of 0.2% peracetic acid disinfectant solution after different storage media and times on the horizontal dimension of IFPD frameworks indexed with AR. MATERIAL AND METHODS: IFPD frameworks were indexed with two AR: group 1 Duralay and group 2 Pattern Resin LS. Each group was further divided into five subgroups according to disinfection procedure and storage medium: no disinfection and dry storage, no disinfection and water storage, 0.2% peracetic acid disinfection and water storage, 0.2% peracetic acid disinfection and peracetic acid storage, and 0.2% peracetic acid disinfection and dry storage. The horizontal dimension of the specimens and an average was established for analysis. Measurements were performed at four different storage times (hours): T0, T24, T48, T168. RESULTS: No statistical differences were found when T0 was compared to T168 for Pattern resin groups submitted to disinfection and storage in water (group 2b, p = 1.000) or peracetic acid solution (group 2c, p = 0.352). For Duralay groups, the use of peracetic acid solution did not affect the horizontal dimension of the specimens when T0 was compared to T168 only with water as a storage medium (group 1b, p = 1.000). Additionally, T0 did not differ from T24 for groups 1c (p = 0.553), 2b (p = 1.000), 2d (p = 0.234), and 2e (p = 1.000) and from T48 for groups 1d (p = 0.118) and 2b (p = 1.000). CONCLUSION: Within the studied conditions, the use of 0.2% peracetic acid can be safely used as a disinfectant solution regarding dimensional stability of AR-indexed IFPD until 7 days of storage. Horizontal discrepancies are dependent on acrylic resin type, time, and medium of storage.
format Online
Article
Text
id pubmed-6749003
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-67490032019-10-04 Effect of 0.2% peracetic acid disinfection on the horizontal dimension of implant framework indexed with two autopolymerized acrylic resins da Fonseca, Emanuely Ronconi Santana, Paula Pereira Xible, Anuar Antonio Curtis, Donald A. Kano, Stefania Carvalho Int J Implant Dent Research BACKGROUND: To minimize misfit between prosthesis and implant, the welding of the implant fixed partial denture (IFPD) framework is recommended and autopolymerized acrylic resin (AR) is the material of choice for the indexing process. As for any prosthetic device that comes into contact with saliva and blood in the oral cavity, IFPD indexed with AR must be disinfected before sending to the laboratory. However, disinfection procedures are often neglected for fear of shrinkage or distortion caused by a dimensional change of the acrylic resin. Peracetic acid is a high-level disinfectant agent at low concentrations and immersion time, with no reported toxic residues, and it is not inactivated in the presence of organic matter when compared to other disinfectants. This study aimed to evaluate the influence of 0.2% peracetic acid disinfectant solution after different storage media and times on the horizontal dimension of IFPD frameworks indexed with AR. MATERIAL AND METHODS: IFPD frameworks were indexed with two AR: group 1 Duralay and group 2 Pattern Resin LS. Each group was further divided into five subgroups according to disinfection procedure and storage medium: no disinfection and dry storage, no disinfection and water storage, 0.2% peracetic acid disinfection and water storage, 0.2% peracetic acid disinfection and peracetic acid storage, and 0.2% peracetic acid disinfection and dry storage. The horizontal dimension of the specimens and an average was established for analysis. Measurements were performed at four different storage times (hours): T0, T24, T48, T168. RESULTS: No statistical differences were found when T0 was compared to T168 for Pattern resin groups submitted to disinfection and storage in water (group 2b, p = 1.000) or peracetic acid solution (group 2c, p = 0.352). For Duralay groups, the use of peracetic acid solution did not affect the horizontal dimension of the specimens when T0 was compared to T168 only with water as a storage medium (group 1b, p = 1.000). Additionally, T0 did not differ from T24 for groups 1c (p = 0.553), 2b (p = 1.000), 2d (p = 0.234), and 2e (p = 1.000) and from T48 for groups 1d (p = 0.118) and 2b (p = 1.000). CONCLUSION: Within the studied conditions, the use of 0.2% peracetic acid can be safely used as a disinfectant solution regarding dimensional stability of AR-indexed IFPD until 7 days of storage. Horizontal discrepancies are dependent on acrylic resin type, time, and medium of storage. Springer Berlin Heidelberg 2019-09-18 /pmc/articles/PMC6749003/ /pubmed/31531734 http://dx.doi.org/10.1186/s40729-019-0186-2 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
da Fonseca, Emanuely Ronconi
Santana, Paula Pereira
Xible, Anuar Antonio
Curtis, Donald A.
Kano, Stefania Carvalho
Effect of 0.2% peracetic acid disinfection on the horizontal dimension of implant framework indexed with two autopolymerized acrylic resins
title Effect of 0.2% peracetic acid disinfection on the horizontal dimension of implant framework indexed with two autopolymerized acrylic resins
title_full Effect of 0.2% peracetic acid disinfection on the horizontal dimension of implant framework indexed with two autopolymerized acrylic resins
title_fullStr Effect of 0.2% peracetic acid disinfection on the horizontal dimension of implant framework indexed with two autopolymerized acrylic resins
title_full_unstemmed Effect of 0.2% peracetic acid disinfection on the horizontal dimension of implant framework indexed with two autopolymerized acrylic resins
title_short Effect of 0.2% peracetic acid disinfection on the horizontal dimension of implant framework indexed with two autopolymerized acrylic resins
title_sort effect of 0.2% peracetic acid disinfection on the horizontal dimension of implant framework indexed with two autopolymerized acrylic resins
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749003/
https://www.ncbi.nlm.nih.gov/pubmed/31531734
http://dx.doi.org/10.1186/s40729-019-0186-2
work_keys_str_mv AT dafonsecaemanuelyronconi effectof02peraceticaciddisinfectiononthehorizontaldimensionofimplantframeworkindexedwithtwoautopolymerizedacrylicresins
AT santanapaulapereira effectof02peraceticaciddisinfectiononthehorizontaldimensionofimplantframeworkindexedwithtwoautopolymerizedacrylicresins
AT xibleanuarantonio effectof02peraceticaciddisinfectiononthehorizontaldimensionofimplantframeworkindexedwithtwoautopolymerizedacrylicresins
AT curtisdonalda effectof02peraceticaciddisinfectiononthehorizontaldimensionofimplantframeworkindexedwithtwoautopolymerizedacrylicresins
AT kanostefaniacarvalho effectof02peraceticaciddisinfectiononthehorizontaldimensionofimplantframeworkindexedwithtwoautopolymerizedacrylicresins