Cargando…
Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn
Ammonia (NH(3)) emission is one of the major environmental issues in livestock farming. Gas measurements are required to study the emission process, to establish emission factors, and to assess the efficiency of emission reduction techniques. However, the current methods for acquiring reference meas...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749270/ https://www.ncbi.nlm.nih.gov/pubmed/31450808 http://dx.doi.org/10.3390/s19173669 |
_version_ | 1783452238781349888 |
---|---|
author | Zhuang, Shaojie Van Overbeke, Philippe Vangeyte, Jürgen Sonck, Bart Demeyer, Peter |
author_facet | Zhuang, Shaojie Van Overbeke, Philippe Vangeyte, Jürgen Sonck, Bart Demeyer, Peter |
author_sort | Zhuang, Shaojie |
collection | PubMed |
description | Ammonia (NH(3)) emission is one of the major environmental issues in livestock farming. Gas measurements are required to study the emission process, to establish emission factors, and to assess the efficiency of emission reduction techniques. However, the current methods for acquiring reference measurements of NH(3) are either high in cost or labor intensive. In this study, a cost-effective ammonia monitoring system (AMS) was constructed from a commercially-available gas analyzing module based on tunable diode laser absorption (TDLA) spectroscopy. To cope with the negative measurement biases caused by differing inlet pressures, a set of correction equations was formulated. Field validation of the AMS on NH(3) measurement was conducted in a fattening pig barn, where the system was compared to a Fourier-transform infrared (FTIR) spectroscopy analyzer. Under two test conditions in a fattening pig barn, the absolute error of the AMS measurements with respect to the average obtained values between the AMS and the FTIR was respectively 0.66 and 0.08 ppm(v), corresponding to 5.9% and 0.5% relative error. Potential sources of the measurement uncertainties in both the AMS and FTIR were discussed. The test results demonstrated that the AMS was capable of performing high-quality measurement with sub-ppm accuracy, making it a promising cost-effective tool for establishing NH(3) emission factors and studying NH(3) emission processes in pig houses. |
format | Online Article Text |
id | pubmed-6749270 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-67492702019-09-27 Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn Zhuang, Shaojie Van Overbeke, Philippe Vangeyte, Jürgen Sonck, Bart Demeyer, Peter Sensors (Basel) Article Ammonia (NH(3)) emission is one of the major environmental issues in livestock farming. Gas measurements are required to study the emission process, to establish emission factors, and to assess the efficiency of emission reduction techniques. However, the current methods for acquiring reference measurements of NH(3) are either high in cost or labor intensive. In this study, a cost-effective ammonia monitoring system (AMS) was constructed from a commercially-available gas analyzing module based on tunable diode laser absorption (TDLA) spectroscopy. To cope with the negative measurement biases caused by differing inlet pressures, a set of correction equations was formulated. Field validation of the AMS on NH(3) measurement was conducted in a fattening pig barn, where the system was compared to a Fourier-transform infrared (FTIR) spectroscopy analyzer. Under two test conditions in a fattening pig barn, the absolute error of the AMS measurements with respect to the average obtained values between the AMS and the FTIR was respectively 0.66 and 0.08 ppm(v), corresponding to 5.9% and 0.5% relative error. Potential sources of the measurement uncertainties in both the AMS and FTIR were discussed. The test results demonstrated that the AMS was capable of performing high-quality measurement with sub-ppm accuracy, making it a promising cost-effective tool for establishing NH(3) emission factors and studying NH(3) emission processes in pig houses. MDPI 2019-08-23 /pmc/articles/PMC6749270/ /pubmed/31450808 http://dx.doi.org/10.3390/s19173669 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhuang, Shaojie Van Overbeke, Philippe Vangeyte, Jürgen Sonck, Bart Demeyer, Peter Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn |
title | Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn |
title_full | Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn |
title_fullStr | Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn |
title_full_unstemmed | Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn |
title_short | Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn |
title_sort | evaluation of a cost-effective ammonia monitoring system for continuous real-time concentration measurements in a fattening pig barn |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749270/ https://www.ncbi.nlm.nih.gov/pubmed/31450808 http://dx.doi.org/10.3390/s19173669 |
work_keys_str_mv | AT zhuangshaojie evaluationofacosteffectiveammoniamonitoringsystemforcontinuousrealtimeconcentrationmeasurementsinafatteningpigbarn AT vanoverbekephilippe evaluationofacosteffectiveammoniamonitoringsystemforcontinuousrealtimeconcentrationmeasurementsinafatteningpigbarn AT vangeytejurgen evaluationofacosteffectiveammoniamonitoringsystemforcontinuousrealtimeconcentrationmeasurementsinafatteningpigbarn AT sonckbart evaluationofacosteffectiveammoniamonitoringsystemforcontinuousrealtimeconcentrationmeasurementsinafatteningpigbarn AT demeyerpeter evaluationofacosteffectiveammoniamonitoringsystemforcontinuousrealtimeconcentrationmeasurementsinafatteningpigbarn |