Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn

Ammonia (NH(3)) emission is one of the major environmental issues in livestock farming. Gas measurements are required to study the emission process, to establish emission factors, and to assess the efficiency of emission reduction techniques. However, the current methods for acquiring reference meas...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhuang, Shaojie, Van Overbeke, Philippe, Vangeyte, Jürgen, Sonck, Bart, Demeyer, Peter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749270/
https://www.ncbi.nlm.nih.gov/pubmed/31450808
http://dx.doi.org/10.3390/s19173669
_version_ 1783452238781349888
author Zhuang, Shaojie
Van Overbeke, Philippe
Vangeyte, Jürgen
Sonck, Bart
Demeyer, Peter
author_facet Zhuang, Shaojie
Van Overbeke, Philippe
Vangeyte, Jürgen
Sonck, Bart
Demeyer, Peter
author_sort Zhuang, Shaojie
collection PubMed
description Ammonia (NH(3)) emission is one of the major environmental issues in livestock farming. Gas measurements are required to study the emission process, to establish emission factors, and to assess the efficiency of emission reduction techniques. However, the current methods for acquiring reference measurements of NH(3) are either high in cost or labor intensive. In this study, a cost-effective ammonia monitoring system (AMS) was constructed from a commercially-available gas analyzing module based on tunable diode laser absorption (TDLA) spectroscopy. To cope with the negative measurement biases caused by differing inlet pressures, a set of correction equations was formulated. Field validation of the AMS on NH(3) measurement was conducted in a fattening pig barn, where the system was compared to a Fourier-transform infrared (FTIR) spectroscopy analyzer. Under two test conditions in a fattening pig barn, the absolute error of the AMS measurements with respect to the average obtained values between the AMS and the FTIR was respectively 0.66 and 0.08 ppm(v), corresponding to 5.9% and 0.5% relative error. Potential sources of the measurement uncertainties in both the AMS and FTIR were discussed. The test results demonstrated that the AMS was capable of performing high-quality measurement with sub-ppm accuracy, making it a promising cost-effective tool for establishing NH(3) emission factors and studying NH(3) emission processes in pig houses.
format Online
Article
Text
id pubmed-6749270
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-67492702019-09-27 Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn Zhuang, Shaojie Van Overbeke, Philippe Vangeyte, Jürgen Sonck, Bart Demeyer, Peter Sensors (Basel) Article Ammonia (NH(3)) emission is one of the major environmental issues in livestock farming. Gas measurements are required to study the emission process, to establish emission factors, and to assess the efficiency of emission reduction techniques. However, the current methods for acquiring reference measurements of NH(3) are either high in cost or labor intensive. In this study, a cost-effective ammonia monitoring system (AMS) was constructed from a commercially-available gas analyzing module based on tunable diode laser absorption (TDLA) spectroscopy. To cope with the negative measurement biases caused by differing inlet pressures, a set of correction equations was formulated. Field validation of the AMS on NH(3) measurement was conducted in a fattening pig barn, where the system was compared to a Fourier-transform infrared (FTIR) spectroscopy analyzer. Under two test conditions in a fattening pig barn, the absolute error of the AMS measurements with respect to the average obtained values between the AMS and the FTIR was respectively 0.66 and 0.08 ppm(v), corresponding to 5.9% and 0.5% relative error. Potential sources of the measurement uncertainties in both the AMS and FTIR were discussed. The test results demonstrated that the AMS was capable of performing high-quality measurement with sub-ppm accuracy, making it a promising cost-effective tool for establishing NH(3) emission factors and studying NH(3) emission processes in pig houses. MDPI 2019-08-23 /pmc/articles/PMC6749270/ /pubmed/31450808 http://dx.doi.org/10.3390/s19173669 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhuang, Shaojie
Van Overbeke, Philippe
Vangeyte, Jürgen
Sonck, Bart
Demeyer, Peter
Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn
title Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn
title_full Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn
title_fullStr Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn
title_full_unstemmed Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn
title_short Evaluation of a Cost-Effective Ammonia Monitoring System for Continuous Real-Time Concentration Measurements in a Fattening Pig Barn
title_sort evaluation of a cost-effective ammonia monitoring system for continuous real-time concentration measurements in a fattening pig barn
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749270/
https://www.ncbi.nlm.nih.gov/pubmed/31450808
http://dx.doi.org/10.3390/s19173669
work_keys_str_mv AT zhuangshaojie evaluationofacosteffectiveammoniamonitoringsystemforcontinuousrealtimeconcentrationmeasurementsinafatteningpigbarn
AT vanoverbekephilippe evaluationofacosteffectiveammoniamonitoringsystemforcontinuousrealtimeconcentrationmeasurementsinafatteningpigbarn
AT vangeytejurgen evaluationofacosteffectiveammoniamonitoringsystemforcontinuousrealtimeconcentrationmeasurementsinafatteningpigbarn
AT sonckbart evaluationofacosteffectiveammoniamonitoringsystemforcontinuousrealtimeconcentrationmeasurementsinafatteningpigbarn
AT demeyerpeter evaluationofacosteffectiveammoniamonitoringsystemforcontinuousrealtimeconcentrationmeasurementsinafatteningpigbarn