Cargando…

Application of Near-Infrared Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) to the Detection of Ammonia in Exhaled Human Breath

The qualitative and quantitative analysis to trace gas in exhaled human breath has become a promising technique in biomedical applications such as disease diagnosis and health status monitoring. This paper describes an application of a high spectral resolution optical feedback cavity enhanced absorp...

Descripción completa

Detalles Bibliográficos
Autores principales: Luo, Zhifu, Tan, Zhongqi, Long, Xingwu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749448/
https://www.ncbi.nlm.nih.gov/pubmed/31450646
http://dx.doi.org/10.3390/s19173686
_version_ 1783452281231900672
author Luo, Zhifu
Tan, Zhongqi
Long, Xingwu
author_facet Luo, Zhifu
Tan, Zhongqi
Long, Xingwu
author_sort Luo, Zhifu
collection PubMed
description The qualitative and quantitative analysis to trace gas in exhaled human breath has become a promising technique in biomedical applications such as disease diagnosis and health status monitoring. This paper describes an application of a high spectral resolution optical feedback cavity enhanced absorption spectroscopy (OF-CEAS) for ammonia detection in exhaled human breath, and the main interference of gases such as CO(2) and H(2)O are approximately eliminated at the same time. With appropriate optical feedback, a fibered distributed feedback (DFB) diode laser emitting at 1531.6 nm is locked to the resonance of a V-shaped cavity with a free spectral range (FSR) of 300 MHz and a finesse of 14,610. A minimum detectable absorption coefficient of α(min) = 2.3 × 10(−9) cm(−1) is achieved in a single scan within 5 s, yielding a detection limit of 17 ppb for NH(3) in breath gas at low pressure, and this stable system allows the detection limit down to 4.5 ppb when the spectra to be averaged over 16 laser scans. Different from typical CEAS with a static cavity, which is limited by the FSR in frequency space, the attainable spectral resolution of our experimental setup can be up to 0.002 cm(−1) owing to the simultaneous laser frequency tuning and cavity dither. Hence, the absorption line profile is more accurate, which is most suitable for low-pressure trace gas detection. This work has great potential for accurate selectivity and high sensitivity applications in human breath analysis and atmosphere sciences.
format Online
Article
Text
id pubmed-6749448
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-67494482019-09-27 Application of Near-Infrared Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) to the Detection of Ammonia in Exhaled Human Breath Luo, Zhifu Tan, Zhongqi Long, Xingwu Sensors (Basel) Article The qualitative and quantitative analysis to trace gas in exhaled human breath has become a promising technique in biomedical applications such as disease diagnosis and health status monitoring. This paper describes an application of a high spectral resolution optical feedback cavity enhanced absorption spectroscopy (OF-CEAS) for ammonia detection in exhaled human breath, and the main interference of gases such as CO(2) and H(2)O are approximately eliminated at the same time. With appropriate optical feedback, a fibered distributed feedback (DFB) diode laser emitting at 1531.6 nm is locked to the resonance of a V-shaped cavity with a free spectral range (FSR) of 300 MHz and a finesse of 14,610. A minimum detectable absorption coefficient of α(min) = 2.3 × 10(−9) cm(−1) is achieved in a single scan within 5 s, yielding a detection limit of 17 ppb for NH(3) in breath gas at low pressure, and this stable system allows the detection limit down to 4.5 ppb when the spectra to be averaged over 16 laser scans. Different from typical CEAS with a static cavity, which is limited by the FSR in frequency space, the attainable spectral resolution of our experimental setup can be up to 0.002 cm(−1) owing to the simultaneous laser frequency tuning and cavity dither. Hence, the absorption line profile is more accurate, which is most suitable for low-pressure trace gas detection. This work has great potential for accurate selectivity and high sensitivity applications in human breath analysis and atmosphere sciences. MDPI 2019-08-25 /pmc/articles/PMC6749448/ /pubmed/31450646 http://dx.doi.org/10.3390/s19173686 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Luo, Zhifu
Tan, Zhongqi
Long, Xingwu
Application of Near-Infrared Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) to the Detection of Ammonia in Exhaled Human Breath
title Application of Near-Infrared Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) to the Detection of Ammonia in Exhaled Human Breath
title_full Application of Near-Infrared Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) to the Detection of Ammonia in Exhaled Human Breath
title_fullStr Application of Near-Infrared Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) to the Detection of Ammonia in Exhaled Human Breath
title_full_unstemmed Application of Near-Infrared Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) to the Detection of Ammonia in Exhaled Human Breath
title_short Application of Near-Infrared Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) to the Detection of Ammonia in Exhaled Human Breath
title_sort application of near-infrared optical feedback cavity enhanced absorption spectroscopy (of-ceas) to the detection of ammonia in exhaled human breath
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749448/
https://www.ncbi.nlm.nih.gov/pubmed/31450646
http://dx.doi.org/10.3390/s19173686
work_keys_str_mv AT luozhifu applicationofnearinfraredopticalfeedbackcavityenhancedabsorptionspectroscopyofceastothedetectionofammoniainexhaledhumanbreath
AT tanzhongqi applicationofnearinfraredopticalfeedbackcavityenhancedabsorptionspectroscopyofceastothedetectionofammoniainexhaledhumanbreath
AT longxingwu applicationofnearinfraredopticalfeedbackcavityenhancedabsorptionspectroscopyofceastothedetectionofammoniainexhaledhumanbreath