Cargando…

Experimental Assessment of Sleep-Related Parameters by Passive Infrared Sensors: Measurement Setup, Feature Extraction, and Uncertainty Analysis

A simple sleep monitoring measurement method is presented in this paper, based on a simple, non-invasive motion sensor, the Passive InfraRed (PIR) motion sensor. The easy measurement set-up proposed is presented and its performances are compared with the ones provided by a commercial, ballistocardio...

Descripción completa

Detalles Bibliográficos
Autores principales: Casaccia, Sara, Braccili, Eleonora, Scalise, Lorenzo, Revel, Gian Marco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749559/
https://www.ncbi.nlm.nih.gov/pubmed/31480405
http://dx.doi.org/10.3390/s19173773
_version_ 1783452303490023424
author Casaccia, Sara
Braccili, Eleonora
Scalise, Lorenzo
Revel, Gian Marco
author_facet Casaccia, Sara
Braccili, Eleonora
Scalise, Lorenzo
Revel, Gian Marco
author_sort Casaccia, Sara
collection PubMed
description A simple sleep monitoring measurement method is presented in this paper, based on a simple, non-invasive motion sensor, the Passive InfraRed (PIR) motion sensor. The easy measurement set-up proposed is presented and its performances are compared with the ones provided by a commercial, ballistocardiographic bed sensor, used as reference tool. Testing was conducted on 25 nocturnal acquisitions with a voluntary, healthy subject, using the PIR-based proposed method and the reference sensor, simultaneously. A dedicated algorithm was developed to correlate the bed sensor outputs with the PIR signal to extract sleep-related features: sleep latency (SL), sleep interruptions (INT), and time to wake (TTW). Such sleep parameters were automatically identified by the algorithm, and then correlated to the ones computed by the reference bed sensor. The identification of these sleep parameters allowed the computation of an important, global sleep quality parameter: the sleep efficiency (SE). It was calculated for each nocturnal acquisition and then correlated to the SE values provided by the reference sensor. Results show the correlation between the SE values monitored with the PIR and the bed sensor with a robust statistic confidence of 4.7% for the measurement of SE (coverage parameter k = 2), indicating the validity of the proposed, unobstructive approach, based on a simple, small, and low-cost sensor, for the assessment of important sleep-related parameters.
format Online
Article
Text
id pubmed-6749559
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-67495592019-09-27 Experimental Assessment of Sleep-Related Parameters by Passive Infrared Sensors: Measurement Setup, Feature Extraction, and Uncertainty Analysis Casaccia, Sara Braccili, Eleonora Scalise, Lorenzo Revel, Gian Marco Sensors (Basel) Article A simple sleep monitoring measurement method is presented in this paper, based on a simple, non-invasive motion sensor, the Passive InfraRed (PIR) motion sensor. The easy measurement set-up proposed is presented and its performances are compared with the ones provided by a commercial, ballistocardiographic bed sensor, used as reference tool. Testing was conducted on 25 nocturnal acquisitions with a voluntary, healthy subject, using the PIR-based proposed method and the reference sensor, simultaneously. A dedicated algorithm was developed to correlate the bed sensor outputs with the PIR signal to extract sleep-related features: sleep latency (SL), sleep interruptions (INT), and time to wake (TTW). Such sleep parameters were automatically identified by the algorithm, and then correlated to the ones computed by the reference bed sensor. The identification of these sleep parameters allowed the computation of an important, global sleep quality parameter: the sleep efficiency (SE). It was calculated for each nocturnal acquisition and then correlated to the SE values provided by the reference sensor. Results show the correlation between the SE values monitored with the PIR and the bed sensor with a robust statistic confidence of 4.7% for the measurement of SE (coverage parameter k = 2), indicating the validity of the proposed, unobstructive approach, based on a simple, small, and low-cost sensor, for the assessment of important sleep-related parameters. MDPI 2019-08-31 /pmc/articles/PMC6749559/ /pubmed/31480405 http://dx.doi.org/10.3390/s19173773 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Casaccia, Sara
Braccili, Eleonora
Scalise, Lorenzo
Revel, Gian Marco
Experimental Assessment of Sleep-Related Parameters by Passive Infrared Sensors: Measurement Setup, Feature Extraction, and Uncertainty Analysis
title Experimental Assessment of Sleep-Related Parameters by Passive Infrared Sensors: Measurement Setup, Feature Extraction, and Uncertainty Analysis
title_full Experimental Assessment of Sleep-Related Parameters by Passive Infrared Sensors: Measurement Setup, Feature Extraction, and Uncertainty Analysis
title_fullStr Experimental Assessment of Sleep-Related Parameters by Passive Infrared Sensors: Measurement Setup, Feature Extraction, and Uncertainty Analysis
title_full_unstemmed Experimental Assessment of Sleep-Related Parameters by Passive Infrared Sensors: Measurement Setup, Feature Extraction, and Uncertainty Analysis
title_short Experimental Assessment of Sleep-Related Parameters by Passive Infrared Sensors: Measurement Setup, Feature Extraction, and Uncertainty Analysis
title_sort experimental assessment of sleep-related parameters by passive infrared sensors: measurement setup, feature extraction, and uncertainty analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749559/
https://www.ncbi.nlm.nih.gov/pubmed/31480405
http://dx.doi.org/10.3390/s19173773
work_keys_str_mv AT casacciasara experimentalassessmentofsleeprelatedparametersbypassiveinfraredsensorsmeasurementsetupfeatureextractionanduncertaintyanalysis
AT braccilieleonora experimentalassessmentofsleeprelatedparametersbypassiveinfraredsensorsmeasurementsetupfeatureextractionanduncertaintyanalysis
AT scaliselorenzo experimentalassessmentofsleeprelatedparametersbypassiveinfraredsensorsmeasurementsetupfeatureextractionanduncertaintyanalysis
AT revelgianmarco experimentalassessmentofsleeprelatedparametersbypassiveinfraredsensorsmeasurementsetupfeatureextractionanduncertaintyanalysis