Cargando…

Comparison of bond strength of two porcelains and two base metal alloys in metal-ceramic restorations

BACKGROUND: The purpose of this study was to evaluate the bond strength between two porcelains (VITA VMK Master and VITA VM13) and two types of base metal alloys (Ceramill Sintron and Verabond). MATERIALS AND METHODS: In an experimental study, 20 rectangular strips (25 mm × 4 mm × 0.5 mm) of each ba...

Descripción completa

Detalles Bibliográficos
Autores principales: Ahmadzadeh, Asadollah, Ghanavati, Saghar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749861/
https://www.ncbi.nlm.nih.gov/pubmed/31543935
_version_ 1783452362362322944
author Ahmadzadeh, Asadollah
Ghanavati, Saghar
author_facet Ahmadzadeh, Asadollah
Ghanavati, Saghar
author_sort Ahmadzadeh, Asadollah
collection PubMed
description BACKGROUND: The purpose of this study was to evaluate the bond strength between two porcelains (VITA VMK Master and VITA VM13) and two types of base metal alloys (Ceramill Sintron and Verabond). MATERIALS AND METHODS: In an experimental study, 20 rectangular strips (25 mm × 4 mm × 0.5 mm) of each base metal alloy (Ceramill Sintron and Verabond) were fabricated according to the manufacturer's instructions. After sandblasting and polishing, the samples were placed in an ultrasonic device to remove surface contaminants. A surface of 8 mm × 4 mm × 1 mm of samples was veneered with Vita VM13 and VITA VMK Master. The samples were divided into four groups (n = 10 each group; VM13/Ceramill, VMK Master/Ceramill, VM13/Verabond, and VMK Master/Verabond), and bond strength was evaluated by three-point bending test with a universal testing machine. Two-way ANOVA was used for comparison in each group, post hoc Scheffe's test was used for analyzing data between groups, and the Kolmogorov–Smirnov test was used for the normality (P < 0.05). RESULTS: The maximum bond strength was related to Verabond/VM13 (44.35 ± 7.9 MPa) and then the Ceramill Sintron/VM13 (39.33 ± 4.43 MPa), and the lowest was related to the Ceramill Sintron/VMK Master (29.75 ± 3.2 MPa). There was no significant difference between bond strength of VM13 with the two alloy groups (P > 0.05), and bond strength of VMK Master to Ceramill Sintron CAD/CAM alloy was less than the conventional Verabond alloy (P < 0.05); however, bond strength of all the groups was above the standard threshold (25 MPa). CONCLUSION: Based on the results of this study, the bond strength of the porcelain to Verabond was better, but the bond strength of the porcelain to Ceramill Sintron also was not less than the standard threshold; thus, this new CAD/CAM alloy can be an alternative to the conventional base metal alloys in the metal-ceramic restorations.
format Online
Article
Text
id pubmed-6749861
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-67498612019-09-20 Comparison of bond strength of two porcelains and two base metal alloys in metal-ceramic restorations Ahmadzadeh, Asadollah Ghanavati, Saghar Dent Res J (Isfahan) Original Article BACKGROUND: The purpose of this study was to evaluate the bond strength between two porcelains (VITA VMK Master and VITA VM13) and two types of base metal alloys (Ceramill Sintron and Verabond). MATERIALS AND METHODS: In an experimental study, 20 rectangular strips (25 mm × 4 mm × 0.5 mm) of each base metal alloy (Ceramill Sintron and Verabond) were fabricated according to the manufacturer's instructions. After sandblasting and polishing, the samples were placed in an ultrasonic device to remove surface contaminants. A surface of 8 mm × 4 mm × 1 mm of samples was veneered with Vita VM13 and VITA VMK Master. The samples were divided into four groups (n = 10 each group; VM13/Ceramill, VMK Master/Ceramill, VM13/Verabond, and VMK Master/Verabond), and bond strength was evaluated by three-point bending test with a universal testing machine. Two-way ANOVA was used for comparison in each group, post hoc Scheffe's test was used for analyzing data between groups, and the Kolmogorov–Smirnov test was used for the normality (P < 0.05). RESULTS: The maximum bond strength was related to Verabond/VM13 (44.35 ± 7.9 MPa) and then the Ceramill Sintron/VM13 (39.33 ± 4.43 MPa), and the lowest was related to the Ceramill Sintron/VMK Master (29.75 ± 3.2 MPa). There was no significant difference between bond strength of VM13 with the two alloy groups (P > 0.05), and bond strength of VMK Master to Ceramill Sintron CAD/CAM alloy was less than the conventional Verabond alloy (P < 0.05); however, bond strength of all the groups was above the standard threshold (25 MPa). CONCLUSION: Based on the results of this study, the bond strength of the porcelain to Verabond was better, but the bond strength of the porcelain to Ceramill Sintron also was not less than the standard threshold; thus, this new CAD/CAM alloy can be an alternative to the conventional base metal alloys in the metal-ceramic restorations. Wolters Kluwer - Medknow 2019-09-05 /pmc/articles/PMC6749861/ /pubmed/31543935 Text en Copyright: © 2019 Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Ahmadzadeh, Asadollah
Ghanavati, Saghar
Comparison of bond strength of two porcelains and two base metal alloys in metal-ceramic restorations
title Comparison of bond strength of two porcelains and two base metal alloys in metal-ceramic restorations
title_full Comparison of bond strength of two porcelains and two base metal alloys in metal-ceramic restorations
title_fullStr Comparison of bond strength of two porcelains and two base metal alloys in metal-ceramic restorations
title_full_unstemmed Comparison of bond strength of two porcelains and two base metal alloys in metal-ceramic restorations
title_short Comparison of bond strength of two porcelains and two base metal alloys in metal-ceramic restorations
title_sort comparison of bond strength of two porcelains and two base metal alloys in metal-ceramic restorations
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749861/
https://www.ncbi.nlm.nih.gov/pubmed/31543935
work_keys_str_mv AT ahmadzadehasadollah comparisonofbondstrengthoftwoporcelainsandtwobasemetalalloysinmetalceramicrestorations
AT ghanavatisaghar comparisonofbondstrengthoftwoporcelainsandtwobasemetalalloysinmetalceramicrestorations