Single-Lumen Endotracheal Tube and Bronchial Blocker for Airway Management During Tracheobronchoplasty for Tracheobronchomalacia: A Case Report
We present a case of a 69-year-old man who underwent tracheobronchoplasty for tracheobronchomalacia using a single-lumen endotracheal tube and a Y-shaped bronchial blocker for airway management. Tracheobronchoplasty is performed by sewing mesh to plicate the posterior, membranous wall of the distal...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health, Inc
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749959/ https://www.ncbi.nlm.nih.gov/pubmed/31385817 http://dx.doi.org/10.1213/XAA.0000000000001076 |
Sumario: | We present a case of a 69-year-old man who underwent tracheobronchoplasty for tracheobronchomalacia using a single-lumen endotracheal tube and a Y-shaped bronchial blocker for airway management. Tracheobronchoplasty is performed by sewing mesh to plicate the posterior, membranous wall of the distal trachea and main bronchi through a right posterolateral thoracotomy. The goals of airway management include continuous left-lung ventilation and lung protection from aspiration. Ideally, only conventional airway management tools are used. This case demonstrates that a single-lumen endotracheal tube with a bronchial blocker can be a straightforward strategy for airway management during tracheobronchoplasty. |
---|