Single-Lumen Endotracheal Tube and Bronchial Blocker for Airway Management During Tracheobronchoplasty for Tracheobronchomalacia: A Case Report
We present a case of a 69-year-old man who underwent tracheobronchoplasty for tracheobronchomalacia using a single-lumen endotracheal tube and a Y-shaped bronchial blocker for airway management. Tracheobronchoplasty is performed by sewing mesh to plicate the posterior, membranous wall of the distal...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health, Inc
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749959/ https://www.ncbi.nlm.nih.gov/pubmed/31385817 http://dx.doi.org/10.1213/XAA.0000000000001076 |
_version_ | 1783452381836476416 |
---|---|
author | Lui, Natalie S. Guo, Haiwei Henry Sung, Arthur W. Peterson, Ashley Kulkarni, Vivekanand N. |
author_facet | Lui, Natalie S. Guo, Haiwei Henry Sung, Arthur W. Peterson, Ashley Kulkarni, Vivekanand N. |
author_sort | Lui, Natalie S. |
collection | PubMed |
description | We present a case of a 69-year-old man who underwent tracheobronchoplasty for tracheobronchomalacia using a single-lumen endotracheal tube and a Y-shaped bronchial blocker for airway management. Tracheobronchoplasty is performed by sewing mesh to plicate the posterior, membranous wall of the distal trachea and main bronchi through a right posterolateral thoracotomy. The goals of airway management include continuous left-lung ventilation and lung protection from aspiration. Ideally, only conventional airway management tools are used. This case demonstrates that a single-lumen endotracheal tube with a bronchial blocker can be a straightforward strategy for airway management during tracheobronchoplasty. |
format | Online Article Text |
id | pubmed-6749959 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer Health, Inc |
record_format | MEDLINE/PubMed |
spelling | pubmed-67499592019-10-07 Single-Lumen Endotracheal Tube and Bronchial Blocker for Airway Management During Tracheobronchoplasty for Tracheobronchomalacia: A Case Report Lui, Natalie S. Guo, Haiwei Henry Sung, Arthur W. Peterson, Ashley Kulkarni, Vivekanand N. A A Pract Case Reports We present a case of a 69-year-old man who underwent tracheobronchoplasty for tracheobronchomalacia using a single-lumen endotracheal tube and a Y-shaped bronchial blocker for airway management. Tracheobronchoplasty is performed by sewing mesh to plicate the posterior, membranous wall of the distal trachea and main bronchi through a right posterolateral thoracotomy. The goals of airway management include continuous left-lung ventilation and lung protection from aspiration. Ideally, only conventional airway management tools are used. This case demonstrates that a single-lumen endotracheal tube with a bronchial blocker can be a straightforward strategy for airway management during tracheobronchoplasty. Wolters Kluwer Health, Inc 2019-08-02 /pmc/articles/PMC6749959/ /pubmed/31385817 http://dx.doi.org/10.1213/XAA.0000000000001076 Text en Copyright © 2019 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the International Anesthesia Research Society. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. |
spellingShingle | Case Reports Lui, Natalie S. Guo, Haiwei Henry Sung, Arthur W. Peterson, Ashley Kulkarni, Vivekanand N. Single-Lumen Endotracheal Tube and Bronchial Blocker for Airway Management During Tracheobronchoplasty for Tracheobronchomalacia: A Case Report |
title | Single-Lumen Endotracheal Tube and Bronchial Blocker for Airway Management During Tracheobronchoplasty for Tracheobronchomalacia: A Case Report |
title_full | Single-Lumen Endotracheal Tube and Bronchial Blocker for Airway Management During Tracheobronchoplasty for Tracheobronchomalacia: A Case Report |
title_fullStr | Single-Lumen Endotracheal Tube and Bronchial Blocker for Airway Management During Tracheobronchoplasty for Tracheobronchomalacia: A Case Report |
title_full_unstemmed | Single-Lumen Endotracheal Tube and Bronchial Blocker for Airway Management During Tracheobronchoplasty for Tracheobronchomalacia: A Case Report |
title_short | Single-Lumen Endotracheal Tube and Bronchial Blocker for Airway Management During Tracheobronchoplasty for Tracheobronchomalacia: A Case Report |
title_sort | single-lumen endotracheal tube and bronchial blocker for airway management during tracheobronchoplasty for tracheobronchomalacia: a case report |
topic | Case Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749959/ https://www.ncbi.nlm.nih.gov/pubmed/31385817 http://dx.doi.org/10.1213/XAA.0000000000001076 |
work_keys_str_mv | AT luinatalies singlelumenendotrachealtubeandbronchialblockerforairwaymanagementduringtracheobronchoplastyfortracheobronchomalaciaacasereport AT guohaiweihenry singlelumenendotrachealtubeandbronchialblockerforairwaymanagementduringtracheobronchoplastyfortracheobronchomalaciaacasereport AT sungarthurw singlelumenendotrachealtubeandbronchialblockerforairwaymanagementduringtracheobronchoplastyfortracheobronchomalaciaacasereport AT petersonashley singlelumenendotrachealtubeandbronchialblockerforairwaymanagementduringtracheobronchoplastyfortracheobronchomalaciaacasereport AT kulkarnivivekanandn singlelumenendotrachealtubeandbronchialblockerforairwaymanagementduringtracheobronchoplastyfortracheobronchomalaciaacasereport |