Cargando…

Hearing Preservation With the Use of Flex(20) and Flex(24) Electrodes in Patients With Partial Deafness

To evaluate the impact of electrode length on hearing preservation (HP) in Partial Deafness Treatment–Electrical Complement (PDT-EC) subjects. STUDY DESIGN: Retrospective case review. SETTING: Tertiary referral center. PATIENTS: Twenty-three PDT-EC patients (with preoperative air-conduction threshol...

Descripción completa

Detalles Bibliográficos
Autores principales: Skarzynski, Piotr H., Skarzynski, Henryk, Dziendziel, Beata, Rajchel, Joanna J., Gos, Elzbieta, Lorens, Artur
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749963/
https://www.ncbi.nlm.nih.gov/pubmed/31318788
http://dx.doi.org/10.1097/MAO.0000000000002357
_version_ 1783452382541119488
author Skarzynski, Piotr H.
Skarzynski, Henryk
Dziendziel, Beata
Rajchel, Joanna J.
Gos, Elzbieta
Lorens, Artur
author_facet Skarzynski, Piotr H.
Skarzynski, Henryk
Dziendziel, Beata
Rajchel, Joanna J.
Gos, Elzbieta
Lorens, Artur
author_sort Skarzynski, Piotr H.
collection PubMed
description To evaluate the impact of electrode length on hearing preservation (HP) in Partial Deafness Treatment–Electrical Complement (PDT-EC) subjects. STUDY DESIGN: Retrospective case review. SETTING: Tertiary referral center. PATIENTS: Twenty-three PDT-EC patients (with preoperative air-conduction thresholds ≤30 dB up to 500 Hz) were divided into two groups: Flex20 electrode (Med-EL GmbH, Innsbruck, Austria) (12 patients) and Flex24 electrode (Med-EL GmbH, Innsbruck, Austria) (11 patients). INTERVENTIONS: All participants were subjected to minimally invasive cochlear implantation using the round window approach. MAIN OUTCOME MEASURE(S): Pure tone audiometry (125–8000 Hz) was performed preoperatively and at 1, 6, 12, and 24 months postoperatively. HP was established using the HEARRING group formula. Speech understanding was assessed preoperatively and at 12 and 24 months postoperatively. RESULTS: Analysis of HP for every individual indicates that more than half the patients with Flex20 and Flex24 had complete HP at 6 months follow-up. None of the patients from either group had complete loss of hearing. At activation, average air-conduction thresholds for low frequencies (125–500 Hz) were slightly better for the short electrode (M = 29.03) than for the long (M = 39.10) but the difference was not statistically significant (p = 0.067). The effect of electrode (Flex20 versus Flex24) was not significant in terms of pure tone audiometry and speech recognition at long-term follow-up. CONCLUSIONS: In the early postoperative period, complete HP was possible in a majority of patients from both groups, but slightly better HP outcomes were achieved by Flex20. In the long term, the length of the electrodes does not affect the degree of HP or speech understanding.
format Online
Article
Text
id pubmed-6749963
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-67499632019-10-07 Hearing Preservation With the Use of Flex(20) and Flex(24) Electrodes in Patients With Partial Deafness Skarzynski, Piotr H. Skarzynski, Henryk Dziendziel, Beata Rajchel, Joanna J. Gos, Elzbieta Lorens, Artur Otol Neurotol Cochlear Implants To evaluate the impact of electrode length on hearing preservation (HP) in Partial Deafness Treatment–Electrical Complement (PDT-EC) subjects. STUDY DESIGN: Retrospective case review. SETTING: Tertiary referral center. PATIENTS: Twenty-three PDT-EC patients (with preoperative air-conduction thresholds ≤30 dB up to 500 Hz) were divided into two groups: Flex20 electrode (Med-EL GmbH, Innsbruck, Austria) (12 patients) and Flex24 electrode (Med-EL GmbH, Innsbruck, Austria) (11 patients). INTERVENTIONS: All participants were subjected to minimally invasive cochlear implantation using the round window approach. MAIN OUTCOME MEASURE(S): Pure tone audiometry (125–8000 Hz) was performed preoperatively and at 1, 6, 12, and 24 months postoperatively. HP was established using the HEARRING group formula. Speech understanding was assessed preoperatively and at 12 and 24 months postoperatively. RESULTS: Analysis of HP for every individual indicates that more than half the patients with Flex20 and Flex24 had complete HP at 6 months follow-up. None of the patients from either group had complete loss of hearing. At activation, average air-conduction thresholds for low frequencies (125–500 Hz) were slightly better for the short electrode (M = 29.03) than for the long (M = 39.10) but the difference was not statistically significant (p = 0.067). The effect of electrode (Flex20 versus Flex24) was not significant in terms of pure tone audiometry and speech recognition at long-term follow-up. CONCLUSIONS: In the early postoperative period, complete HP was possible in a majority of patients from both groups, but slightly better HP outcomes were achieved by Flex20. In the long term, the length of the electrodes does not affect the degree of HP or speech understanding. Lippincott Williams & Wilkins 2019-10 2019-07-10 /pmc/articles/PMC6749963/ /pubmed/31318788 http://dx.doi.org/10.1097/MAO.0000000000002357 Text en Copyright © 2019 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of Otology & Neurotology, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle Cochlear Implants
Skarzynski, Piotr H.
Skarzynski, Henryk
Dziendziel, Beata
Rajchel, Joanna J.
Gos, Elzbieta
Lorens, Artur
Hearing Preservation With the Use of Flex(20) and Flex(24) Electrodes in Patients With Partial Deafness
title Hearing Preservation With the Use of Flex(20) and Flex(24) Electrodes in Patients With Partial Deafness
title_full Hearing Preservation With the Use of Flex(20) and Flex(24) Electrodes in Patients With Partial Deafness
title_fullStr Hearing Preservation With the Use of Flex(20) and Flex(24) Electrodes in Patients With Partial Deafness
title_full_unstemmed Hearing Preservation With the Use of Flex(20) and Flex(24) Electrodes in Patients With Partial Deafness
title_short Hearing Preservation With the Use of Flex(20) and Flex(24) Electrodes in Patients With Partial Deafness
title_sort hearing preservation with the use of flex(20) and flex(24) electrodes in patients with partial deafness
topic Cochlear Implants
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749963/
https://www.ncbi.nlm.nih.gov/pubmed/31318788
http://dx.doi.org/10.1097/MAO.0000000000002357
work_keys_str_mv AT skarzynskipiotrh hearingpreservationwiththeuseofflex20andflex24electrodesinpatientswithpartialdeafness
AT skarzynskihenryk hearingpreservationwiththeuseofflex20andflex24electrodesinpatientswithpartialdeafness
AT dziendzielbeata hearingpreservationwiththeuseofflex20andflex24electrodesinpatientswithpartialdeafness
AT rajcheljoannaj hearingpreservationwiththeuseofflex20andflex24electrodesinpatientswithpartialdeafness
AT goselzbieta hearingpreservationwiththeuseofflex20andflex24electrodesinpatientswithpartialdeafness
AT lorensartur hearingpreservationwiththeuseofflex20andflex24electrodesinpatientswithpartialdeafness