Cargando…

Comparing Arterial- and Venous-Phase Acquisition for Optimization of Virtual Noncontrast Images From Dual-Energy Computed Tomography Angiography

Follow-up with computed tomographic angiography is recommended after endovascular aneurysm repair, exposing patients to significant levels of radiation and iodine contrast medium. Dual-energy computed tomography allows virtual noncontrast (VNC) images to be reconstructed from contrast-enhanced image...

Descripción completa

Detalles Bibliográficos
Autores principales: Lehti, Leena, Söderberg, Marcus, Höglund, Peter, Wassélius, Johan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6752687/
https://www.ncbi.nlm.nih.gov/pubmed/31425308
http://dx.doi.org/10.1097/RCT.0000000000000903
_version_ 1783452772196155392
author Lehti, Leena
Söderberg, Marcus
Höglund, Peter
Wassélius, Johan
author_facet Lehti, Leena
Söderberg, Marcus
Höglund, Peter
Wassélius, Johan
author_sort Lehti, Leena
collection PubMed
description Follow-up with computed tomographic angiography is recommended after endovascular aneurysm repair, exposing patients to significant levels of radiation and iodine contrast medium. Dual-energy computed tomography allows virtual noncontrast (VNC) images to be reconstructed from contrast-enhanced images using a software algorithm. If the VNC images are a good-enough approximation of true noncontrast (TNC) images, a reduction in radiation dose can be ensured through omitting a TNC scan. PURPOSE: To compare image quality of VNC images reconstructed from arterial phase and venous phase dual-energy computed tomographic angiography to TNC images and to assess which one is more suitable to replace TNC images. METHODS: Sixty-three consecutive patients were examined using a dual-energy computed tomography as elective follow-up after endovascular aneurysm repair. The examination protocol included 1 unenhanced and 2 contrast-enhanced scans (80 kV/Sn140 kV) of the aorta. Virtual noncontrast data sets were reconstructed from the arterial (A-VNC) and venous (V-VNC) phase scans, respectively. Mean attenuation and image noise were measured for TNC, A-VNC, and V-VNC images within regions of interest at 2 levels in the aorta, the liver, retroperitoneal fat, and psoas muscle. Subjective image quality was assessed on a 4-point scale by 2 blinded readers. RESULTS: The differences between A-VNC and TNC, and between A-VNC and V-VNC, were substantial aorta at the level of diaphragm and aorta at the level of renal arteries. The difference between V-VNC and TNC was, on the other hand, very small and not statistically significant for the renal artery aorta. For liver, fat, and muscle tissue, there were significant differences between both A-VNC and V-VNC compared with TNC, but findings were similar between A-VNC and V-VNC. CONCLUSIONS: Virtual noncontrast images based on venous-phase scans appear to be a more accurate representation of TNC scans than VNC images based on arterial-phase scans.
format Online
Article
Text
id pubmed-6752687
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-67526872019-10-07 Comparing Arterial- and Venous-Phase Acquisition for Optimization of Virtual Noncontrast Images From Dual-Energy Computed Tomography Angiography Lehti, Leena Söderberg, Marcus Höglund, Peter Wassélius, Johan J Comput Assist Tomogr Abdominal Imaging Follow-up with computed tomographic angiography is recommended after endovascular aneurysm repair, exposing patients to significant levels of radiation and iodine contrast medium. Dual-energy computed tomography allows virtual noncontrast (VNC) images to be reconstructed from contrast-enhanced images using a software algorithm. If the VNC images are a good-enough approximation of true noncontrast (TNC) images, a reduction in radiation dose can be ensured through omitting a TNC scan. PURPOSE: To compare image quality of VNC images reconstructed from arterial phase and venous phase dual-energy computed tomographic angiography to TNC images and to assess which one is more suitable to replace TNC images. METHODS: Sixty-three consecutive patients were examined using a dual-energy computed tomography as elective follow-up after endovascular aneurysm repair. The examination protocol included 1 unenhanced and 2 contrast-enhanced scans (80 kV/Sn140 kV) of the aorta. Virtual noncontrast data sets were reconstructed from the arterial (A-VNC) and venous (V-VNC) phase scans, respectively. Mean attenuation and image noise were measured for TNC, A-VNC, and V-VNC images within regions of interest at 2 levels in the aorta, the liver, retroperitoneal fat, and psoas muscle. Subjective image quality was assessed on a 4-point scale by 2 blinded readers. RESULTS: The differences between A-VNC and TNC, and between A-VNC and V-VNC, were substantial aorta at the level of diaphragm and aorta at the level of renal arteries. The difference between V-VNC and TNC was, on the other hand, very small and not statistically significant for the renal artery aorta. For liver, fat, and muscle tissue, there were significant differences between both A-VNC and V-VNC compared with TNC, but findings were similar between A-VNC and V-VNC. CONCLUSIONS: Virtual noncontrast images based on venous-phase scans appear to be a more accurate representation of TNC scans than VNC images based on arterial-phase scans. Lippincott Williams & Wilkins 2019 2019-08-16 /pmc/articles/PMC6752687/ /pubmed/31425308 http://dx.doi.org/10.1097/RCT.0000000000000903 Text en Copyright © 2019 The Author(s). Published by Wolters Kluwer Health, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Abdominal Imaging
Lehti, Leena
Söderberg, Marcus
Höglund, Peter
Wassélius, Johan
Comparing Arterial- and Venous-Phase Acquisition for Optimization of Virtual Noncontrast Images From Dual-Energy Computed Tomography Angiography
title Comparing Arterial- and Venous-Phase Acquisition for Optimization of Virtual Noncontrast Images From Dual-Energy Computed Tomography Angiography
title_full Comparing Arterial- and Venous-Phase Acquisition for Optimization of Virtual Noncontrast Images From Dual-Energy Computed Tomography Angiography
title_fullStr Comparing Arterial- and Venous-Phase Acquisition for Optimization of Virtual Noncontrast Images From Dual-Energy Computed Tomography Angiography
title_full_unstemmed Comparing Arterial- and Venous-Phase Acquisition for Optimization of Virtual Noncontrast Images From Dual-Energy Computed Tomography Angiography
title_short Comparing Arterial- and Venous-Phase Acquisition for Optimization of Virtual Noncontrast Images From Dual-Energy Computed Tomography Angiography
title_sort comparing arterial- and venous-phase acquisition for optimization of virtual noncontrast images from dual-energy computed tomography angiography
topic Abdominal Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6752687/
https://www.ncbi.nlm.nih.gov/pubmed/31425308
http://dx.doi.org/10.1097/RCT.0000000000000903
work_keys_str_mv AT lehtileena comparingarterialandvenousphaseacquisitionforoptimizationofvirtualnoncontrastimagesfromdualenergycomputedtomographyangiography
AT soderbergmarcus comparingarterialandvenousphaseacquisitionforoptimizationofvirtualnoncontrastimagesfromdualenergycomputedtomographyangiography
AT hoglundpeter comparingarterialandvenousphaseacquisitionforoptimizationofvirtualnoncontrastimagesfromdualenergycomputedtomographyangiography
AT wasseliusjohan comparingarterialandvenousphaseacquisitionforoptimizationofvirtualnoncontrastimagesfromdualenergycomputedtomographyangiography