Cargando…
Does a spinal implant alter dual energy X-ray absorptiometry body composition measurements?
BACKGROUND: Most manufacturer manuals do not verify the use of dual energy X-ray absorptiometry for body composition analysis in subjects with a metal implant. This study aimed to quantify the effects of a spinal implant on body composition, and to determine whether unadjusted lean mass estimates ar...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6752773/ https://www.ncbi.nlm.nih.gov/pubmed/31536597 http://dx.doi.org/10.1371/journal.pone.0222758 |
_version_ | 1783452782421868544 |
---|---|
author | Hsiao, Pei-Lin Hsu, Shu-Feng Chen, Po-Han Tsai, Hsiao-Wei Lu, Hsin-Ying Wang, Yue-Sheng Lee, Li-Wen |
author_facet | Hsiao, Pei-Lin Hsu, Shu-Feng Chen, Po-Han Tsai, Hsiao-Wei Lu, Hsin-Ying Wang, Yue-Sheng Lee, Li-Wen |
author_sort | Hsiao, Pei-Lin |
collection | PubMed |
description | BACKGROUND: Most manufacturer manuals do not verify the use of dual energy X-ray absorptiometry for body composition analysis in subjects with a metal implant. This study aimed to quantify the effects of a spinal implant on body composition, and to determine whether unadjusted lean mass estimates are valid for patients with a spinal implant. METHODS: A total of 30 healthy subjects were recruited. Three consecutive scans were performed for each participant, one with and two without extraneous spinal implant, without repositioning between scans. Lean, fat and bone estimates in the total body, trunk and limb were measured. RESULTS: Precision errors for all total and regional body compositions were within the recommended ranges. Bone masses in the trunk and total body were significantly increased with spinal implant, and the increases exceeded the least significant change. For total and regional lean and fat estimates, the measurements between subjects with and without metal implants were in substantial to almost perfect agreement and the differences were not significant and did not exceed the least significant change. CONCLUSIONS: Spinal metal artifacts significantly increased the total body and trunk bone mass but the differences in lean- and fat-related estimates at total and regional body levels and all estimates in the extremity remained within the clinical acceptable range. Thus, a spinal implant may not compromise screening of patients for fat and lean masses using dual energy X-ray absorptiometry. Application of image reconstruction or a filtering algorithm may help reduce the effect of metallic artifacts and further study is needed. |
format | Online Article Text |
id | pubmed-6752773 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-67527732019-09-27 Does a spinal implant alter dual energy X-ray absorptiometry body composition measurements? Hsiao, Pei-Lin Hsu, Shu-Feng Chen, Po-Han Tsai, Hsiao-Wei Lu, Hsin-Ying Wang, Yue-Sheng Lee, Li-Wen PLoS One Research Article BACKGROUND: Most manufacturer manuals do not verify the use of dual energy X-ray absorptiometry for body composition analysis in subjects with a metal implant. This study aimed to quantify the effects of a spinal implant on body composition, and to determine whether unadjusted lean mass estimates are valid for patients with a spinal implant. METHODS: A total of 30 healthy subjects were recruited. Three consecutive scans were performed for each participant, one with and two without extraneous spinal implant, without repositioning between scans. Lean, fat and bone estimates in the total body, trunk and limb were measured. RESULTS: Precision errors for all total and regional body compositions were within the recommended ranges. Bone masses in the trunk and total body were significantly increased with spinal implant, and the increases exceeded the least significant change. For total and regional lean and fat estimates, the measurements between subjects with and without metal implants were in substantial to almost perfect agreement and the differences were not significant and did not exceed the least significant change. CONCLUSIONS: Spinal metal artifacts significantly increased the total body and trunk bone mass but the differences in lean- and fat-related estimates at total and regional body levels and all estimates in the extremity remained within the clinical acceptable range. Thus, a spinal implant may not compromise screening of patients for fat and lean masses using dual energy X-ray absorptiometry. Application of image reconstruction or a filtering algorithm may help reduce the effect of metallic artifacts and further study is needed. Public Library of Science 2019-09-19 /pmc/articles/PMC6752773/ /pubmed/31536597 http://dx.doi.org/10.1371/journal.pone.0222758 Text en © 2019 Hsiao et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Hsiao, Pei-Lin Hsu, Shu-Feng Chen, Po-Han Tsai, Hsiao-Wei Lu, Hsin-Ying Wang, Yue-Sheng Lee, Li-Wen Does a spinal implant alter dual energy X-ray absorptiometry body composition measurements? |
title | Does a spinal implant alter dual energy X-ray absorptiometry body composition measurements? |
title_full | Does a spinal implant alter dual energy X-ray absorptiometry body composition measurements? |
title_fullStr | Does a spinal implant alter dual energy X-ray absorptiometry body composition measurements? |
title_full_unstemmed | Does a spinal implant alter dual energy X-ray absorptiometry body composition measurements? |
title_short | Does a spinal implant alter dual energy X-ray absorptiometry body composition measurements? |
title_sort | does a spinal implant alter dual energy x-ray absorptiometry body composition measurements? |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6752773/ https://www.ncbi.nlm.nih.gov/pubmed/31536597 http://dx.doi.org/10.1371/journal.pone.0222758 |
work_keys_str_mv | AT hsiaopeilin doesaspinalimplantalterdualenergyxrayabsorptiometrybodycompositionmeasurements AT hsushufeng doesaspinalimplantalterdualenergyxrayabsorptiometrybodycompositionmeasurements AT chenpohan doesaspinalimplantalterdualenergyxrayabsorptiometrybodycompositionmeasurements AT tsaihsiaowei doesaspinalimplantalterdualenergyxrayabsorptiometrybodycompositionmeasurements AT luhsinying doesaspinalimplantalterdualenergyxrayabsorptiometrybodycompositionmeasurements AT wangyuesheng doesaspinalimplantalterdualenergyxrayabsorptiometrybodycompositionmeasurements AT leeliwen doesaspinalimplantalterdualenergyxrayabsorptiometrybodycompositionmeasurements |