Cargando…

Implant-based multi-parameter telemonitoring of patients with heart failure and a defibrillator with vs. without cardiac resynchronization therapy option: a subanalysis of the IN-TIME trial

AIMS: In the IN-TIME trial, automatic daily implant-based multiparameter telemonitoring significantly improved clinical outcomes in patients with chronic systolic heart failure and implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D). We compared IN...

Descripción completa

Detalles Bibliográficos
Autores principales: Geller, Johann Christoph, Lewalter, Thorsten, Bruun, Niels Eske, Taborsky, Milos, Bode, Frank, Nielsen, Jens Cosedis, Stellbrink, Christoph, Schön, Steffen, Mühling, Holger, Oswald, Hanno, Reif, Sebastian, Kääb, Stefan, Illes, Peter, Proff, Jochen, Dagres, Nikolaos, Hindricks, Gerhard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6753058/
https://www.ncbi.nlm.nih.gov/pubmed/30874886
http://dx.doi.org/10.1007/s00392-019-01447-5
Descripción
Sumario:AIMS: In the IN-TIME trial, automatic daily implant-based multiparameter telemonitoring significantly improved clinical outcomes in patients with chronic systolic heart failure and implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D). We compared IN-TIME results for ICD and CRT-D subgroups. METHODS: Patients with LVEF ≤ 35%, NYHA class II/III, optimized drug treatment, no permanent atrial fibrillation, and a dual-chamber ICD (n = 274) or CRT-D (n = 390) were randomized 1:1 to telemonitoring or no telemonitoring for 12 months. Primary outcome measure was a composite clinical score, classified as worsened if the patient died or had heart failure-related hospitalization, worse NYHA class, or a worse self-reported overall condition. RESULTS: The prevalence of worsened score at study end was higher in CRT-D than ICD patients (26.4% vs. 18.2%; P = 0.014), as was mortality (7.4% vs. 4.1%; P = 0.069). With telemonitoring, odds ratios (OR) for worsened score and hazard ratios (HR) for mortality were similar in the ICD [OR = 0.55 (P = 0.058), HR = 0.39 (P = 0.17)] and CRT-D [OR = 0.68 (P = 0.10), HR = 0.35 (P = 0.018)] subgroups (insignificant interaction, P = 0.58–0.91). CONCLUSION: Daily multiparameter telemonitoring has a potential to reduce clinical endpoints in patients with chronic systolic heart failure both in ICD and CRT-D subgroups. The absolute benefit seems to be higher in higher-risk populations with worse prognosis. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00392-019-01447-5) contains supplementary material, which is available to authorized users.