Pull-off characteristics of double-shanked compared to single-shanked ligation clips: an animal study
BACKGROUND: The use of surgical ligation clips is considered as the gold standard for the closure of vessels, particularly in laparoscopic surgery. The safety of clips is mainly achieved by the deep indentation of the metal bar with a high retention force. A novel double-shanked (DS) titanium clip w...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
De Gruyter
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6753983/ https://www.ncbi.nlm.nih.gov/pubmed/31579717 http://dx.doi.org/10.1515/iss-2016-0003 |
_version_ | 1783452998396018688 |
---|---|
author | Schenk, Martin Müller, Gottfried Greiner, Tim Oliver Fahrner, Christine Königsrainer, Alfred Thiel, Christian |
author_facet | Schenk, Martin Müller, Gottfried Greiner, Tim Oliver Fahrner, Christine Königsrainer, Alfred Thiel, Christian |
author_sort | Schenk, Martin |
collection | PubMed |
description | BACKGROUND: The use of surgical ligation clips is considered as the gold standard for the closure of vessels, particularly in laparoscopic surgery. The safety of clips is mainly achieved by the deep indentation of the metal bar with a high retention force. A novel double-shanked (DS) titanium clip was compared to two single-shanked clips with respect to axial and radial pull-off forces. METHODS: In a porcine model (8 animals, 51±1 kg), arteries were prepared immediately after euthanisation, assigned to either a medium (2–4 mm; n=120) or a medium-large (3.5–7 mm; n=120) clip size group, and clipped with the appropriate clip size. After dissection, axial and radial pull-off forces were measured. RESULTS: The axial pull-off force of the DS-Clip was higher than one single-shanked clip and comparable to the other single-shanked clip, and overall was linearly correlated to the cross-sectional area of the clip. The radial pull-off force of the DS-Clip was significantly higher than both single-shanked clips and, for the single-shanked clips, was correlated to the total clip thickness. The variation of radial pull-off force was lower for the DS-Clip due to a defined catch in the clip applier. CONCLUSIONS: The radial pull-off force was lower than the axial pull-off force in total and therefore appears to be the critical point of dislocation. Due to the higher total holding mass, the DS-Clip provided a clear advantage in this regard and might therefore decrease the dislocation rate. The catch in the applier increases the reproducibility in clip placement. |
format | Online Article Text |
id | pubmed-6753983 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | De Gruyter |
record_format | MEDLINE/PubMed |
spelling | pubmed-67539832019-10-02 Pull-off characteristics of double-shanked compared to single-shanked ligation clips: an animal study Schenk, Martin Müller, Gottfried Greiner, Tim Oliver Fahrner, Christine Königsrainer, Alfred Thiel, Christian Innov Surg Sci Original Articles BACKGROUND: The use of surgical ligation clips is considered as the gold standard for the closure of vessels, particularly in laparoscopic surgery. The safety of clips is mainly achieved by the deep indentation of the metal bar with a high retention force. A novel double-shanked (DS) titanium clip was compared to two single-shanked clips with respect to axial and radial pull-off forces. METHODS: In a porcine model (8 animals, 51±1 kg), arteries were prepared immediately after euthanisation, assigned to either a medium (2–4 mm; n=120) or a medium-large (3.5–7 mm; n=120) clip size group, and clipped with the appropriate clip size. After dissection, axial and radial pull-off forces were measured. RESULTS: The axial pull-off force of the DS-Clip was higher than one single-shanked clip and comparable to the other single-shanked clip, and overall was linearly correlated to the cross-sectional area of the clip. The radial pull-off force of the DS-Clip was significantly higher than both single-shanked clips and, for the single-shanked clips, was correlated to the total clip thickness. The variation of radial pull-off force was lower for the DS-Clip due to a defined catch in the clip applier. CONCLUSIONS: The radial pull-off force was lower than the axial pull-off force in total and therefore appears to be the critical point of dislocation. Due to the higher total holding mass, the DS-Clip provided a clear advantage in this regard and might therefore decrease the dislocation rate. The catch in the applier increases the reproducibility in clip placement. De Gruyter 2016-06-15 /pmc/articles/PMC6753983/ /pubmed/31579717 http://dx.doi.org/10.1515/iss-2016-0003 Text en ©2016, Martin Schenk et al., published by De Gruyter. http://creativecommons.org/licenses/by-nc-nd/4.0 This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License. |
spellingShingle | Original Articles Schenk, Martin Müller, Gottfried Greiner, Tim Oliver Fahrner, Christine Königsrainer, Alfred Thiel, Christian Pull-off characteristics of double-shanked compared to single-shanked ligation clips: an animal study |
title | Pull-off characteristics of double-shanked compared to single-shanked ligation clips: an animal study |
title_full | Pull-off characteristics of double-shanked compared to single-shanked ligation clips: an animal study |
title_fullStr | Pull-off characteristics of double-shanked compared to single-shanked ligation clips: an animal study |
title_full_unstemmed | Pull-off characteristics of double-shanked compared to single-shanked ligation clips: an animal study |
title_short | Pull-off characteristics of double-shanked compared to single-shanked ligation clips: an animal study |
title_sort | pull-off characteristics of double-shanked compared to single-shanked ligation clips: an animal study |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6753983/ https://www.ncbi.nlm.nih.gov/pubmed/31579717 http://dx.doi.org/10.1515/iss-2016-0003 |
work_keys_str_mv | AT schenkmartin pulloffcharacteristicsofdoubleshankedcomparedtosingleshankedligationclipsananimalstudy AT mullergottfried pulloffcharacteristicsofdoubleshankedcomparedtosingleshankedligationclipsananimalstudy AT greinertimoliver pulloffcharacteristicsofdoubleshankedcomparedtosingleshankedligationclipsananimalstudy AT fahrnerchristine pulloffcharacteristicsofdoubleshankedcomparedtosingleshankedligationclipsananimalstudy AT konigsraineralfred pulloffcharacteristicsofdoubleshankedcomparedtosingleshankedligationclipsananimalstudy AT thielchristian pulloffcharacteristicsofdoubleshankedcomparedtosingleshankedligationclipsananimalstudy |