Cargando…

Design and Validation of Multichannel Wireless Wearable SEMG System for Real-Time Training Performance Monitoring

Monitoring of training performance and physical activity has become indispensable these days for athletes. Wireless technologies have started to be widely used in the monitoring of muscle activation, in the sport performance of athletes, and in the examination of training efficiency. The monitorabil...

Descripción completa

Detalles Bibliográficos
Autores principales: Örücü, Serkan, Selek, Murat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6754969/
https://www.ncbi.nlm.nih.gov/pubmed/31583067
http://dx.doi.org/10.1155/2019/4580645
_version_ 1783453151751307264
author Örücü, Serkan
Selek, Murat
author_facet Örücü, Serkan
Selek, Murat
author_sort Örücü, Serkan
collection PubMed
description Monitoring of training performance and physical activity has become indispensable these days for athletes. Wireless technologies have started to be widely used in the monitoring of muscle activation, in the sport performance of athletes, and in the examination of training efficiency. The monitorability of performance simultaneously in the process of training is especially a necessity for athletes at the beginner level to carry out healthy training in sports like weightlifting and bodybuilding. For this purpose, a new system consisting of 4 channel wireless wearable SEMG circuit and analysis software has been proposed to detect dynamic muscle contractions and to be used in real-time training performance monitoring and analysis. The analysis software, the Haar wavelet filter with threshold cutting, can provide performance analysis by using the methods of moving RMS and %MVC. The validity of the data obtained from the system was investigated and compared with a biomedical system. In this comparison, 90.95% ± 3.35 for left biceps brachii (BB) and 90.75% ± 3.75 for right BB were obtained. The output of the power and %MVC analysis of the system was tested during the training of the participants at the gym, and the training efficiency was measured as 96.87% ± 2.74.
format Online
Article
Text
id pubmed-6754969
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-67549692019-10-03 Design and Validation of Multichannel Wireless Wearable SEMG System for Real-Time Training Performance Monitoring Örücü, Serkan Selek, Murat J Healthc Eng Research Article Monitoring of training performance and physical activity has become indispensable these days for athletes. Wireless technologies have started to be widely used in the monitoring of muscle activation, in the sport performance of athletes, and in the examination of training efficiency. The monitorability of performance simultaneously in the process of training is especially a necessity for athletes at the beginner level to carry out healthy training in sports like weightlifting and bodybuilding. For this purpose, a new system consisting of 4 channel wireless wearable SEMG circuit and analysis software has been proposed to detect dynamic muscle contractions and to be used in real-time training performance monitoring and analysis. The analysis software, the Haar wavelet filter with threshold cutting, can provide performance analysis by using the methods of moving RMS and %MVC. The validity of the data obtained from the system was investigated and compared with a biomedical system. In this comparison, 90.95% ± 3.35 for left biceps brachii (BB) and 90.75% ± 3.75 for right BB were obtained. The output of the power and %MVC analysis of the system was tested during the training of the participants at the gym, and the training efficiency was measured as 96.87% ± 2.74. Hindawi 2019-09-09 /pmc/articles/PMC6754969/ /pubmed/31583067 http://dx.doi.org/10.1155/2019/4580645 Text en Copyright © 2019 Serkan Örücü and Murat Selek. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Örücü, Serkan
Selek, Murat
Design and Validation of Multichannel Wireless Wearable SEMG System for Real-Time Training Performance Monitoring
title Design and Validation of Multichannel Wireless Wearable SEMG System for Real-Time Training Performance Monitoring
title_full Design and Validation of Multichannel Wireless Wearable SEMG System for Real-Time Training Performance Monitoring
title_fullStr Design and Validation of Multichannel Wireless Wearable SEMG System for Real-Time Training Performance Monitoring
title_full_unstemmed Design and Validation of Multichannel Wireless Wearable SEMG System for Real-Time Training Performance Monitoring
title_short Design and Validation of Multichannel Wireless Wearable SEMG System for Real-Time Training Performance Monitoring
title_sort design and validation of multichannel wireless wearable semg system for real-time training performance monitoring
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6754969/
https://www.ncbi.nlm.nih.gov/pubmed/31583067
http://dx.doi.org/10.1155/2019/4580645
work_keys_str_mv AT orucuserkan designandvalidationofmultichannelwirelesswearablesemgsystemforrealtimetrainingperformancemonitoring
AT selekmurat designandvalidationofmultichannelwirelesswearablesemgsystemforrealtimetrainingperformancemonitoring